1. Catalogs
  2. LARUS DESIGN
  3. Intercontinental

Intercontinental

Intercontinental

Intercontinental

Product catalog summary
Overview: The document outlines technical specifications for Larus's Intercontinental product line, including benches, paper bins, bollards, and planters. It covers materials, dimensions, fixing systems, and evaluates the pros and cons of various materials and processes.
Product Specifications:
  • Benches: Options with or without backrests, featuring steel structures and seats made from Tali wood, FSC French Oak, or FSC Kambala wood. Fixing system: LF1.
  • Paper Bin: Constructed from steel with a security lock and a rotomolded plastic inner container, with a 30L capacity. Fixing system: LF1.
  • Bollard: Features a steel structure with a top made from Tali wood, FSC French Oak, or FSC Kambala wood. Fixing system: LF3.
  • Planter: Made with a steel structure and fixing system LF6.
Material Descriptions:
  • Steel: EN10025 alloy with low carbon content for ductility and mechanical strength. Stainless steel includes at least 11% chromium for corrosion resistance.
  • Corten Steel: Develops a stable rust-like appearance with high copper content, preventing further oxidation.
  • Cast Iron: A ferrous alloy with high carbon content, available in lamellar gray and nodular forms, known for vibration damping and corrosion resistance.
Surface Protection and Coating:
  • Metallization: Zinc or zinc/aluminum alloy is applied for corrosion protection, with a thickness of 30-40 microns.
  • Galvanization: Involves zinc bath immersion, providing a coating of at least 60 microns. Suitable for hollow pieces but not for cast iron.
Wood Characteristics: Wood is a renewable material with low production energy consumption. It requires treatments to prevent water, fungi, and UV damage.
Fixing Systems: Includes rods anchored on concrete (LF1), direct anchoring (LF3), and floorstanding (LF6).
Material References: Detailed references for materials like steel, aluminum, concrete, and wood, including specific types and treatments.
Standards and Norms: References standards such as SIS 055900, AFNOR, and ISO 2063 for material and process specifications.
Wood Characteristics and Treatment: Wood is renewable and CO2 neutral but susceptible to fungi, bacteria, and UV damage. Proper drying and preservation treatments are essential.
Galvanization Process: Zinc immersion forms a zinc/iron alloy with a minimum thickness of 60 microns. Not suitable for cast iron due to high silicon and phosphorus content.
Paint and Coatings: Includes enamel forge, epoxy, synthetic enamel, polyurethane enamel, and electrostatic powder coating, each offering different durability and resistance levels.
Wood Varnish and Maintenance: Varnishes with iron oxides protect against UV rays. Regular maintenance involves sanding and varnishing every two years.
Public Lighting and Photovoltaic Systems: LED lighting provides safety with high color rendering and long lifespan. Photovoltaic systems store energy for nighttime use.
Polymer Transformation Process: Involves heating polymers like polyethylene in a metallic mold for even distribution and solidification.
Protection of People: Electric shock protection is ensured through the TT system, using neutral earthing and earthed mass, complemented by security measures.
Facility Security: Thermal-Magnetic Breakers protect against overloads and short circuits.
RAL Colors: Various RAL colors are available, with additional colors upon request.
See more

Catalog excerpts

Intercontinental-1

Intercontinental line | ligne | linha design Larus EN Simple and contemporary conception characterized by angular faces. FR Conception simple et contemporaine, dominée par des faces angulaires. PT Desenho simples e contemporâneo, caracterizado por faces angulares.

 Open the catalog to page 1
Intercontinental-2

Intercontinental line | ligne | linha bench with backrest banc avec dossier banco com costas bench without backrest banc sans dossier banco sem costas planter jardiniere floreira bollard borne dissuasor EN Benches Structure: steel [LA1 / LA2] Seat: Tali wood / FSC French Oak wood or FSC Kambala wood [LV1] Fixing: [LF1] Paper bin Structure: steel [LA1 / LA2] Security lock: yes Garbage disposal: rotomolded plastic inner container [LR1] Capacity: 30L Fixing: [LF1] Bollard Structure: steel [LA1 / LA2] Top: Tali wood / FSC French Oak wood or FSC Kambala wood [LV1] Fixing: [LF3] Planter Structure:...

 Open the catalog to page 2
Intercontinental-3

pictogram list liste des pictogrammes legenda de pictogramas cast iron fonte ferro fundido glulam bois lamelée madeira lamelada cast aluminium fonte aluminium alumínio fundido particleboard aggloméré de bois aglomerado de madeira rotomolded plastic plastique rotomoulé plástico rotomoldado phenolic resin (HPL) résine phénolique (HPL) resina fenólica (HPL) sandwich panel panneau sandwich painel sandwich stainless steel acier inoxydable aço inoxidável plastic plastique plástico corten steel acier corten aço corten dupont corian corian dupont corian dupont aluminium aluminium alumínio perforated...

 Open the catalog to page 3
Intercontinental-4

material references références des matériaux referências de materiais steel S275JR galvanized and painted acier S275JR galvanisé et peint aço S275JR galvanizado e pintado steel S275JR metallized and painted acier S275JR acier métallisée et peint aço S275JR metalizado e pintado washed concrete béton lavé betão lavado LR1 rotomolded plastic in polyethylene resin plastique rotomoulé avec résine de polyéthylène plástico rotomoldado com resina de polietileno LAC1 corten steel A S 335 J2 G2W acier corten A S 335 J2 G2W aço corten A S 335 J2 G2W LAL1 extruded and anodized aluminum (C177.006, C117.007...

 Open the catalog to page 4
Intercontinental-5

Steel / Stainless Steel Acier / Acier Inox Aço / Aço inox Cast Iron Fonte Ferro Fundido EN Steel (EN10025) is an alloy combining iron and carbon, with a maximum carbon content of approx. 2.1%. With low carbon content (<0.3%), has a high ductility and good characteristics for the mechanical work and welding. Stainless steel, contain at least 11% of chromium, ensuring a high resistance against corrosion, forming a thin adhesive film, which protects the material from corrosive attacks in contact with water or moist air (AISI 304). With the appropriate additions of chromium, nickel and molybdenum,...

 Open the catalog to page 5
Intercontinental-6

Galvanization Galvanisation Galvanização Wood Bois Madeira Pour chaque utilisation, il faut employer EN Protection of the surface, obtained by EN Wood is one of the most important the immersion in a bath of zinc (min 98% les bois possédant les caractéristiques building materials and requires an energy of pure zinc) at about 450 °C. The zinc conseillées, et faire également appel à des comsumption for its production (5 to 7.5 metallurgically reacts with the metal surface traitements de préservation. KWH / Ton) much lower than other materials of the piece. The thickness of the zinc layer Après abattage,...

 Open the catalog to page 6
Intercontinental-7

Cracks and warping in wood Fentes et Gauchissements (bois) Fendas e Empenos na madeira Protective varnish/lasur in wood Vernis/lasure protecteur (bois) Verniz protector na madeira Paint Peinture Pintura EN The action of the U.V. rays causes the EN Enamel Forge - On the primer a metal degradation of lignin, favoring its decay. enamel is applied with high anticorrosive Varnish possesses iron oxides working power and weather resistance. It has the as parallel lamellae to timber surface, appearance of wrought iron. promoting the reflection of the U.V. rays. The Epoxy - iron oxide paint, with higher...

 Open the catalog to page 7
Intercontinental-8

Electricity Electricité Electricidade Rotomolding Rotomoulage Rotomoldagem Public Lighting EN Thermic transformation process of Ensuring the safety of outdoor public spaces polymers (above a certain temperature), like (EN 13 201). LED lighting: color rendering polyethylene (PE), polypropylene (PP) or PVC. index (CRI> 75); color temperature to be The polymers powder is filled into a metallic defined; average life span 60.000h (highest); mould, which is exposed to a biaxial low energy consumption. movement and heated to a temperature which can go until 300ºC. Photovoltaic systems High temperature...

 Open the catalog to page 8

All LARUS DESIGN catalogs and technical brochures

  1. 2023LARUSDESIGN

    240  Pages

  2. Pilaretes

    8  Pages

  3. Fradinhos

    8  Pages

  4. Vesúvio

    8  Pages

  5. Ecopontos

    8  Pages

  6. ALFACINHA

    8  Pages

  7. Sheet

    8  Pages

  8. Gemini

    8  Pages

  9. UFO

    10  Pages

  10. A Grates

    12  Pages

  11. Ciclo

    8  Pages

  12. Rondo

    8  Pages

  13. Poste Larus

    8  Pages

  14. MUPI

    8  Pages

  15. TANGO

    8  Pages

  16. Sueste

    8  Pages

  17. Urb

    8  Pages

  18. Lisboa

    8  Pages

  19. Arqui kiosk

    8  Pages

  20. Mondrian

    8  Pages

  21. Jardim

    8  Pages

  22. Banca Ardina

    8  Pages

  23. Daciano

    8  Pages

  24. Arqui

    8  Pages

  25. Alex

    8  Pages

  26. Villa

    8  Pages

  27. Polis

    2  Pages

  28. Unic

    8  Pages

  29. Mateo

    8  Pages

  30. Ludwig

    8  Pages

  31. Lótus

    8  Pages

  32. IP6

    8  Pages

  33. Embondeiro

    8  Pages

  34. Elegance

    8  Pages

  35. Degrau

    8  Pages

  36. Corten

    8  Pages

  37. Comendador

    8  Pages

  38. Cais

    8  Pages

  39. Bussaco

    8  Pages

  40. Boomerang

    8  Pages

  41. Balarés

    8  Pages

  42. Axis

    8  Pages

  43. Ária

    8  Pages

  44. ARC

    8  Pages

  45. Africa Life

    15  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.