REGULATION & CONTROL - 1

,r.^REGULATION AND CONTROL GEISER INOX "i'-. ' "lapesa" control panels are integrated into the different types of tanks in the "GEISER INOX" series. They are supplied fully wired and mounted on the tank. The panels include all the necessary components to control the temperature of the DHW stored in the tank and for the thermostatic control of the installation's heating equipment. Any of the standard control panels fitted in tanks can be replaced by another type of control panel, if the installation so requires. CONTROL PANEL COMPONENTS: • [Te° ] Thermometer: 0 - 120°C • [TL°] Control thermostat: 0 - 75°C • [TL°] Safety thermostat: 90°C • ®/o Switch: winter - summer • Power on LED: green • Primary pump LED: amber • Electric heating element LED: red • [P] Analog time switch: electric heating element. COMPONENTS ON CONTROL PANELS CONTROL PANEL INCORPORATED COMPONENTS Regulation Safety thermostat thermostat SWITCH SUMMER/ WINTER Analog time switch Standard installed on tank models "GEISER INOX" S" PANEL ST" PANEL E" PANEL K" PANEL KP1" PANEL BC" PANEL hydraulic primary circuit electric heating element hydraulic primary circuit / electric heating element hydraulic primary circuit / electric heating element with time programming hydraulic primary circuit with heat pump