GEISER INOX DOUBLE WALL
8Pages

{{requestButtons}}

Catalog excerpts

GEISER INOX DOUBLE WALL - 1

GEISER INOX - STAINLESS STEEL The water contained in the surrounding tank or primary tank is heated by an external energy source (boiler, heat pump, solar collectors, etc.) that passes through this vessel and transmits its thermal energy to the water contained in the inner tank or DHW storage tank. DOUBLE-WALL TANKS: This is the star product of the "GEISER INOX" series thanks its many advantages over conventional DHW production systems. The DOUBLE-WALL system basically consists of a combination of two tanks, one inside the other. DHW production takes place by the exchange of heat from the external or primary tank to the internal or secondary tank (DHW), throughout the whole of the tank's surface. The water contained in the surrounding tank or primary tank is heated by an external energy source (boiler, heat pump, solar collectors, etc.) that passes through this vessel and transmits its thermal energy to the water contained in the inner tank or DHW storage tank.

Open the catalog to page 1
GEISER INOX DOUBLE WALL - 2

DHW PRODUCTION/STORAGE TANKS GEISER INOX - DOUBLE WALL LONG-LASTING PRODUCT: Nickel-chromium-molybdenum STAINLESS STEEL DHW storage tank, highly resistant to pitting caused by halogen elements such as chlorine in drinking water. This is the material used to manufacture all of the models in our “GEISER INOX” series. SELF-CLEANING EFFECT: Corrugated design of the DHW storage tank, in constant vertical movement depending on the fluctuations in the internal pressure, which helps to detach any limescale from the walls. ANTI LEGIONELLA DESIGN: Totally uniform DHW storage temperature, with no cold...

Open the catalog to page 2
GEISER INOX DOUBLE WALL - 3

DHW PRODUCTION/STORAGE TANKS GEISER INOX - DOUBLE WALL GEISER INOX "S" - DOUBLE-WALL storage tank for the production of DHW by heat exchange between the surrounding tank (primary circuit) and the internal tank (DHW), via an external energy source (boiler, solar panels, heat pump, etc.). Finish: RAL 9016 white external lining and RAL 7021 grey cover. For VERTICAL or HORIZONTAL installation. Designed for wall mounting, up to GX6 S190 model. EQUIPMENT: DHW thermometer on top cover. Brackets for wall mounting, up to GX6 S190 model. c - inspection hole d - DHW tank e - heating chamber f -...

Open the catalog to page 3
GEISER INOX DOUBLE WALL - 4

DHW PRODUCTION/STORAGE TANKS GEISER INOX - DOUBLE WALL GEISER INOX "TS"- DOUBLE-WALL storage tank for the production of DHW by heat exchange between the surrounding tank (primary circuit) and the internal tank (DHW), via an external energy source (boiler, solar panels, heat pump, etc.). Specifically designed for HORIZONTAL INSTALLATION. Finish: RAL 9016 white external lining and black covers. Able to withstand the weight of a boiler of up to 700 kg on top. EQUIPMENT: Thermometer & DHW regulation thermostat on front cover. GENERAL CHARACTERISTICS c - inspection hole d - DHW tank e - heating...

Open the catalog to page 4
GEISER INOX DOUBLE WALL - 5

DHW PRODUCTION/STORAGE TANKS GEISER INOX - DOUBLE WALL GEISER INOX "D" - DOUBLE-WALL storage tank for the production of DHW by means of heat exchange between the surrounding tank (primary circuit) and the internal tank (DHW), via an external energy source (boiler, solar panels, heat pump, etc.). Equipped with side hole in primary circuit for optional incorporation of electric heating element. Finish: RAL 9016 white external lining and RAL 7021 grey cover. Designed for wall mounting, up to GX6 D190 model. EQUIPMENT: "K" control panel, wired and mounted, with thermometer, dual safety and...

Open the catalog to page 5
GEISER INOX DOUBLE WALL - 6

DHW PRODUCTION/STORAGE TANKS GEISER INOX - DOUBLE WALL GEISER INOX "DE" - DOUBLE-WALL storage tank for the production of DHW by means of heat exchange between the surrounding tank (primary circuit) and the internal tank (DHW), via an external energy source (boiler, solar panels, heat pump, etc.). Equipped with side threaded connection in primary circuit for optional incorporation of an "RI"-type THREADED electric heating element. Finish: RAL 9016 white external lining and RAL 7021 grey cover. Designed for wall mounting, up to GX6 DE190 model. EQUIPMENT: "K" control panel, wired and mounted,...

Open the catalog to page 6
GEISER INOX DOUBLE WALL - 7

DHW PRODUCTION/STORAGE TANKS GEISER INOX - DOUBLE WALLGEISER INOX "DEC"- DOUBLE-WALL storage tank for the production of DHW by means of heat exchange between the surrounding tank (primary circuit) and the internal tank (DHW), via an external energy source (boiler, solar panels, heat pump, etc.). Equipped with side hole in primary circuit, with factory-mounted electric heating element. Finish: RAL 9016 white external lining and RAL 7021 grey cover. EQUIPMENT: Full electric heating unit, factory-mounted and wired, comprising electric heating element and "K" control panel, with thermometer,...

Open the catalog to page 7
GEISER INOX DOUBLE WALL - 8

nothing but advantages! Models DOUBLE WALL • STAINLESS STEEL STORAGE TANK • LARGE DHW PRODUCTION CAPACITY • SELF-CLEANING EFFECT • ANTI-LEGIONELLA DESIGN STAINLESS STEEL TANKS • MAXIMUM STORAGE CAPACITY • MAINTENANCE-F

Open the catalog to page 8