LAMILUX DAYLIGHT SYSTEMS RENOVATION
24Pages

{{requestButtons}}

Catalog excerpts

LAMILUX DAYLIGHT SYSTEMS RENOVATION - 1

LAMILUX DAYLIGHT SYSTEMS RENOVATION Dem Kunden dienen als Programm

Open the catalog to page 1
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 2

LAMILUX RENOVATION “Upkeep is an important topic in construction, as we cannot only think in terms of new buildings. Renovation, refurbishment and upgrading of buildings and parts of buildings is the clear future of the industry and even the present. It is an issue construction specialists will be addressing on an ever more frequent basis. We are therefore constantly working on solutions that bring daylight, fresh air and safety into existing buildings of any age from above. " Alexander Strunz Executive Manager LAMILUX Heinrich Strunz GmbH The LAMILUX CI Philosophy Customer value is the...

Open the catalog to page 2
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 3

Renovation of Flat Roofs Renovation with LAMILUX Fall-through Proofing LAMILUX Renovation Solutions Rooflight and Glass Skylight References - Rooflight and Glass Skylight Continuous Rooflight and Glass Roof References - Continuous Rooflight and Glass Roof ihn Page 4 Page 6 Page 8 Page 10 Page 10 Page 12 Page 16 Page 18

Open the catalog to page 3
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 4

In order to maintain the function of a roof, the flat roof needs to be checked for damage on a regular basis. Undetected leaks can quickly become very expensive. The consequences of longterm damage can often only become apparent in your skylights when it is too late, for example porous sealing or weather-related damage to skylights. To ensure that you have an intact and functional flat roof in the future and are also on the safe side from a legal point of view, you should make appropriate provisions. Are you aware of the condition of your daylight elements and SHEV systems? Is the thermal...

Open the catalog to page 4
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 5

RENOVATION OF FLAT ROOFS Would you like some assistance from a LAMILUX expert? Scan here and find your local contact person.

Open the catalog to page 5
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 6

Renovation requires expertise - so it’s good to have a competent partner like LAMILUX by your side. Statutory regulations, health regulations and industrial requirements call for customised and tailor-made solutions, especially on business premises. For this reason, take advantage of our decades of experience and receive comprehensive and optimum service. We will find you not only the most efficient, but also the most economical solution for your rooflights, glass skylights, continuous roof-lights or even for your glass roofs. In addition, we are able to install on any on-site supporting...

Open the catalog to page 6
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 7

RENOVATION WITH LAMILUX

Open the catalog to page 7
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 8

FALL-THROUGH PROTECTION Fall-through protection is an issue of ever greater importance on flat roofs. If a person falls from the roof, the operator of the building is responsible and also personally liable. For this reason, we recommend: Equip your roof with fall-through protection. LAMILUX offer various fall-through protection solutions on and in the glazing, under the glazing as well as on and in the roof opening – for all our daylight elements such as rooflights, glass skylights, continuous rooflights and glass roofs. Accidents involving falls do not only happen because untrained...

Open the catalog to page 8
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 9

FALL-THROUGH PROTECTION

Open the catalog to page 9
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 10

Here you can access the checklists for renovation on LAMILUX and all on-site upstands. LAMILUX RENOVATION SOLUTIONS ROOFLIGHT AND GLASS SKYLIGHT We offer you made-to-order solutions for the renovation of your circular and square rooflight domes and flat roof windows. With our renovation frames we are able to mount on any onsite upstand to ensure easy exchange. If the roof is also renovated in terms of energy efficiency, the roof system is usually heightened. In such cases, our heightening elements, which are mounted on the on-site upstand, are the right choice. Glass is a profitable,...

Open the catalog to page 10
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 11

LAMILUX RENOVATION SOLUTIONS LAMILUX Glass Skylight F100 or LAMILUX Glass Skylight FE LAMILUX Glass Skylight Optional Heightening Element Existing on-site upstand 1 LAMILUX Glass Skylight F100 2 LAMILUX Glass Skylight FE 5 Existing on-site upstand LAMILUX Rooflight F100 or LAMILUX Glass Skylight FE 3° LAMILUX Rooflight / Glass Skylight Optional Heightening Element Existing on-site upstand 2 LAMILUX Glass Skylight FE 3° 5 Existing on-site upstand

Open the catalog to page 11
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 12

RENOVATION EXAMPLE ROOFLIGHT F100 BATTENFELD, MEDEBACH The roof and skylights were starting to show their age. This was noticeable both from the lack of daylight, as the windows had become cloudy, and from the energy values of the hall. 57 thermally separated LAMILUX Rooflights F100 free of thermal bridges with double opal glazing in lockable ventilation design GRP Heightening Elements implemented in smoke and heat exhaust ventilation units for connecting the rooflights to the upstands existing on-site 46 fall-through protection grids under the glazing

Open the catalog to page 12
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 13

LAMILUX RENOVATION SOLUTIONS RENOVATION EXAMPLE GLASS SKYLIGHT F100 CARITAS, HAGEN Dirt deposits on the daylight elements and the ageing of such elements had significantly reduced the daylight intake. 54 LAMILUX Glass Skylights F100 Nine LAMILUX Glass Skylights FE Fall-through protection provided by the glazing as per GS-Bau 18 or DIN 18008-6 Flush-mounted glazing in the border frame to ensure planar water drainage for preventing dirt dep

Open the catalog to page 13
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 14

RENOVATION EXAMPLE GLASS SKYLIGHT FE 3° VOGEL CONVENTION CENTRE, WÜRZBURG The yellowed rooflights as well as the old wired glass shed roofs did not do justice – neither in terms of energy efficiency or visually – to the showpiece building of the event centre and publishing house. 23 LAMILUX Glass Skylights FE 3° as an energy-efficiency upgrade and fall-through protection thanks to real glass, 16 of which in ventilated design Three LAMILUX Glass Roofs PR60 as shed roof with 60° inclination and each one 40 metres in length including heat-insulated base point with circumferential secondary...

Open the catalog to page 14
LAMILUX DAYLIGHT SYSTEMS RENOVATION - 15

LAMILUX RENOVATION SOLUTIONS RENOVATION EXAMPLE GLASS SKYLIGHT FE 3° PAULUSKIRCHE, TRAUNREUT Before the renovation The chancel provides a unique view of the bell tower thanks to the skylights. However, the yellowed plastic glazing obstructed this view when it came down to it and also made it difficult for daylight to enter the church. Eight LAMILUX Glass Skylights FE 3° and a sound insulation value of 38 dB Mounted on eight LAMILUX Renovation Frames 11 to ensure safe installation on the existing supporting struct

Open the catalog to page 15

All LAMILUX Heinrich Strunz GmbH catalogs and technical brochures

  1. Anti Slip

    2 Pages

  2. ROOFS OF LIGHT