Overview: The LAARS® Mighty Therm® Copper-Finned Gas-Fired Volume Water Heaters are designed for high efficiency and space-saving applications, achieving energy efficiencies up to 82%. Suitable for both indoor and outdoor installations, they can operate on natural or propane gas. The document also covers models VW, PW, and IW, designed for large volume hot water applications in residential complexes, hotels, schools, and hospitals.
Specifications: The heaters are certified by IAS under ANSI Standard Z21.13 and comply with ASME Boiler and Pressure Vessel Code Section IV. They have a working pressure of 160 psi and feature integral finned copper tubes for efficient heat transfer. Model VW ranges from 175,000 to 5,000,000 BTU/hr, Model PW includes a factory-mounted pump with inputs from 175,000 to 1,825,000 BTU/hr, and Model IW is designed for instantaneous hot water delivery without a storage tank, available in sizes from 500,000 to 1,825,000 BTU/hr.
Construction: The units feature a lightweight cast refractory combustion chamber, stainless steel burners, and a galvanized steel chassis with an acrylic finish. The heat exchanger is replaceable without disassembling the burners or combustion chamber.
Controls and Safety: Control systems meet ANSI and Canadian Gas Association standards, including ignition safeguard, manual reset high limit, and gas pressure regulator. Standard control systems operate on 24 VAC power.
Standard Features: Key features include no fire-side gasketing, slide-out burner tray, flanged connections, and electronic flame supervision. Available firing modes include on/off, two-stage, and modulating options.
Optional Equipment: Options include enhanced gas train components, advanced control systems, and energy management monitors.
Dimensional and Sizing Data: Detailed dimensions and sizing data are provided for both indoor and outdoor models, including input/output ratings and recovery tables for different temperature rises.
Installation Notes: Specific clearance requirements are outlined for maintenance accessibility, and installation on non-combustible floors is required for certain models. The heaters are fully assembled at the factory for ease of installation, with emphasis on selecting the correct pump size to accommodate pressure drop through the heat exchanger and additional piping.
Pump Requirements: A suitable pump must be provided to ensure adequate temperature rise and correct flow based on water hardness, accounting for 30 ft. of piping and normal fittings.
Contact Information: Laars Heating Systems provides contact details for customer service and applications engineering support.
See more

Catalog excerpts

Mighty Therm Volume Water Heaters-1

LAARS MIGHTY THERM ® Copper-Finned Gas-Fired Volume Water Heaters

 Open the catalog to page 1
Mighty Therm Volume Water Heaters-2

LAARS MIGHTY THERM ® QUIET, EFFICIENT, SPACE-SAVING Greater energy efficiencies as Integral finned copper tubes Controls meet requirements of meeting ASME specification SB through state-of-the-art design. 75 are rolled directly into Efficient heat transfer and headers. Heat exchanger baffles standards and include ignition reduced standby losses result in safeguard, manual reset high lower operating costs. tubing configuration extract limit, operating temperature combustion heat with maximum control, gas pressure regulator, (International Approval Services, redundant electric gas valve a joint...

 Open the catalog to page 2
Mighty Therm Volume Water Heaters-3

STANDARD FEATURES • • • • • • • • • • • • • • • • • No fire-side gasketing Slide-out burner tray (sizes 175-1825) Flanged connections 160 PSI working pressure Constructed to Section IV, ASME Boiler and Pressure Vessel Code Factory mounted pump (sizes 175-1825, Models IW & PW) Design certified and tested by I.A.S. (A.G.A. & C.G.A.) Meets requirements of ASHRAE Standard 90.1 Electronic flame supervision Natural or propane gas Electronic ignition, standard on sizes 500 and above Pilot gas regulator On/off switch with indicator light Over-current circuit protection Non-combustible base - standard...

 Open the catalog to page 3
Mighty Therm Volume Water Heaters-4

DIMENSIONAL AND SIZING DATA INDOOR MODELS Indoor Size Water Conn. Size inches NPT OUTDOOR MODELS Outdoor Size Water Conn. Size inches NPT Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude. Dimensions are nominal. Units with pumps: Add 20 lbs. (9 kg) to sizes 175-400 and 55 lbs. (25 kg) to sizes 500-1825. When two gas connection sizes are shown, the smaller applies to the standard gas train, while the larger applies to optional trains, such as four stage or motorized gas valves. Consult factory for exact specifications.

 Open the catalog to page 4
Mighty Therm Volume Water Heaters-5

DIMENSIONAL DIAGRAMS Inlet Outlet * Cast Iron 5%, Bronze 23A INDOOR OUTDOOR Dimensions shown are inches cm.

 Open the catalog to page 5
Mighty Therm Volume Water Heaters-6

RECOVERY TABLES INDOOR MODELS Required Water Temperature Rise Indoor Size Outdoor Size Required Water Temperature Rise Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude. Dimensions are nominal. Units with pumps: Add 20 lbs. (9 kg) to sizes 175-400 and 55 lbs. (25 kg) to sizes 500-1825. When two gas connection sizes are shown, the smaller applies to the standard gas train, while the larger applies to optional trains, such as four stage or motorized gas valves. Consult factory for exact specifications.

 Open the catalog to page 6
Mighty Therm Volume Water Heaters-7

PUMP REQUIREMENTS GUIDE A suitable pump must be field-provided for circulation of water between Model VW heater and the storage tank(s). The pump must be sized to provide adequate temperature rise through the heater, while producing correct flow for prevailing water hardness conditions. Specifications in this table include allowance for 30 ft. (9.1 m) of piping and normal fittings between heater and tank. This allowance is based on flange connection size (see chart). Flow Rate Size Indoor Outdoor Head Loss Flow Rate Head Loss Water Conn. Size Temp. Rise Across Heater ˚F Sizes 1200, 1430, 1670...

 Open the catalog to page 7
Mighty Therm Volume Water Heaters-8

MODELS AVAILABLE Model VW Volume Water Heater Volume Water Heater with Pump Instantaneous Volume Water Heater Completely assembled at the factory and simple to install. Sizes 175,000 to 400,000 BTU/hr. (51.3 to 117.2 kW) are combination indoor/ outdoor. Sizes 500,000 to 5,000,000 BTU/hr. (146.5 to 1465.0 kW) can be ordered either indoor or outdoor. Both series are used in conjunction with storage wherever a large volume of hot water is required, such as apartments/condominiums, hotels, schools, hospitals and laundries. The addition of a factory mounted and matched pump provides installation and...