Catalog excerpts
POLYUREA RAYSTON Pure polyurea membrane for waterproofing in spray applications. DESCRIPTION TECHNICAL DATA Polyurea Rayston is a 2-component polyurea system for elastic membrane application with crackbridging capability. It is an extra fastcuring system that can only be applied by hot mechanical spraying equipment. Polyurea Rayston can be combined with different geotextiles to obtain on site applied, seamless INFORMATION ON THE PRODUCT BEFORE APPLICATION Packaging Note: Pigment is delivered in a third container. See Pigment Spray data sheet for specific details. Waterproofing of foundations, especially those designed as barriers to Radon gas. Roof Lead content Aromatic isocyanate prepolymer Component C (pigment paste) Metal can (4 kg or 0.4 kg) Non-volatile content Physical state Component A Chemical description Flash point Colour Yellow (without pigment) (may darken along wastewater treatment structures. On-site applied liners, totally seamless, for secondary containment applications, ponds, landfills, tunnels, canals, dam repairing. Protective coating for metallic structures Polyurea Rayston can be completed with an aliphatic polyurethane topcoat to ensure UV protection. Crack-bridging capability. Highly elastic membrane. Very fast curing, using twocomponent spraying equipment. Fast polymerization (see pot life data) Dark yellow, but component A is pigmented by addition of pigment paste (Pigment Spray) delivered with each kit of Polyurea Rayston. Curing performance Gel time mixture A+B (20 g): 4 s at 25ºC 3 s at 60ºC Tack free time: 30 s at 70ºC CERTIFICATIONS CE marking according to EN 1504-2: 0370-CPR-2247 ETA (ETAG005): European Technical Assessment, Nº 16/0148 BBA certificate (UK) for roofing, nº18/5582 Radon diffusion coefficient according to ISO 11665-13 Applus (Independent laboratory): 12 months after manufacturing date. INFORMATION ON THE FINAL PRODUCT Drinking water certification (Migration test): nº 928/09/8505 Contact with alcoholic beverages. Simulation C as per regulation EU 10/2011 (EN 1186): pass. Certificate 928/11/4106 M1 Dynamic and Static indentation test according to EOTA. 11/2855-1315 Contact with fuel products (UNE 48307:2011) Exp 13/6620-457 Hardness (Shore) • External fire resistance EN 13501-5:2005+A1 :2010 AITEX (Independent laboratory): • Static indentation/CBR UNE-EN-ISO 12236:2007. • Tear, according to UNE-EN ISO 34-1:2011 Water Regulations Advisory Scheme LTD. (WRAS) Material Approval (United Kingdom, contact with water intended for human consumption). Approval number 1709541 Final state Colour Elastomeric solid membrane Available Pigment Spray pastes are blue RAL 5015, Gray RAL 7011. Tile red, Beige RAL 1001. Other pastes are available under request. 80-85% 87A/35D (ISO 868) Tear strength Polyurea Rayston is an aromatic isocyanate-based product. A colour change is to be expected under sunlight. This change does not affect its mechanical properties. An additional UV protection can be provided with an Impertrans/Colodur topcoat. KRYPTON CHEMICAL SL C/ Martí iFranquès, 12 - Pol. Ind. les Tàpies 43890 - l'Hospitalet de l'Infant - Spain Tel: +34 977 822 245 - Fax: +34 977 823 977 www.kryptonchemical.com – rayston@krypt
Open the catalog to page 1POLYUREA RAYSTON Pure polyurea membrane for waterproofing in spray applications. Abrasion resistance Adhesion strength Concrete (with epoxy primer) Plywood (with epoxy primer) 1.6 (cohesive wood failure) μ = 31419. Sd > 50 (if coating thickness larger than 1,6 mm (EN ISO 7783:2012) Steel (PU primer) High density PU foam Stable up to 200ºC (6-hour test). According to low temperature tests, (UNE_EN 495- (150kg/m3) Fibrous cement (with 2001), the membrane can be folded at -45ºC without cracking or breaks. Water vapour Adhesion strength resistance factor Liquid water permeability Carbon dioxide...
Open the catalog to page 2POLYUREA RAYSTON Pure polyurea membrane for waterproofing in spray applications. Use 1 kg/m2 minimum. APPLICATION AND RECOMMENDED QUANTITIES Polyurea Rayston must be applied using 2-component hot spraying equipment. The use of a compressed air dryer (refrigeration dryer) or compressed air- drying filters is recommended. hiding power Gray colour darkens upon Pressure should be at least 140 bar while spraying. Mix and homogenize pigment in component A before spraying Apply an aliphatic topcoat Impertrans, Colodur) During spraying, check coating thickness to ensure curing evolution is correct....
Open the catalog to page 3POLYUREA RAYSTON Pure polyurea membrane for waterproofing in spray applications. they do not constitute any product guarantee for the installer, who must consider them as simple information. We recommend to study deeply all information provided before proceeding to the use or application of any of our products, and strongly advise to conduct tests “on-site” to determine their convenience for a specific project. Our recommendations do not exempt of the obligation of installers to deeply study the right application method for these systems before use, as well as to conduct as many preliminary...
Open the catalog to page 4All KRYPTON CHEMICAL catalogs and technical brochures
-
EP COAT 100
2 Pages
-
COLODUR ECO
3 Pages
-
IMPERMAX POLYUREA H FLEX
3 Pages
-
IMPERMAX POLYUREA H
3 Pages