Supply grilles – Series 26
10Pages

{{requestButtons}}

Catalog excerpts

Supply grilles – Series 26 - 2

Example of grille selection 8

Open the catalog to page 2
Supply grilles – Series 26 - 3

Curvilinear Blade Supply Air Grilles Description The Series 26 curved blade grilles are especially designed for providing any type of discharge: from the absolute horizontal airstream to the complete vertical airstream, regardless of whether they are ceiling or wall mounted. The grilles can be used in cooling as well as heating systems, given the great discharge airstream control flexibility of their blades. The curvilinear blade supply air grille is especially recommended for rooms with a difficult air distribution. Its curvilinear blades reduce air currents and even ensure air spreading....

Open the catalog to page 3
Supply grilles – Series 26 - 4

Arrangements Arrangement

Open the catalog to page 4
Supply grilles – Series 26 - 7

The data listed in the selection tables have been determined using arrangement (a) as a baseline (refer to page 3). For other arrangements, apply the correction factors in Table 1. All these values correspond to a temperature gradient between the supply and room air of 10 C. During the cooling process, the throw will slightly decrease while the drop will increase. On the contrary, in the heating process, the throws will slightly increase. Maximum: It is the distance in m (measured in a plane parallel to the grille) from the centre of the grille to a point in which the residual velocity is...

Open the catalog to page 7
Supply grilles – Series 26 - 8

Applications Wall applications In heating operation, it is recommended that the discharge velocity does not exceed 1.5 m/sec. In cooling operation, the maximum throws must be equal or greater than the distance from the grille to the ceiling. Free space: The grille is considered to be located in a free space when the maximum throw is reached at a point between 3/4 and the total distance to the nearest wall. The airstream drop in cooling operation will not be excessive if the supply air flow is less than what is indicated in Table 3. When the grille is installed detached from the ceiling, e....

Open the catalog to page 8
Supply grilles – Series 26 - 9

THIS CATALOGUE IS INTELLECTUAL PROPERTY. Partial or complete reproduction of its contents is prohibited without the written and certified consent of KOOLAIR, S.A

Open the catalog to page 9
Supply grilles – Series 26 - 10

KOOLAIR, S.A. Calle Urano, 26 Poligono industrial nº 2 – La Fuensanta 28936 Móstoles - Madrid - (España) Tel: +34 91 645 00 33 Fax: +34 91 645 69 62 e-mail: info@koolair.com

Open the catalog to page 10

All KOOLAIR S.A catalogs and technical brochures

  1. series FLOOR

    23 Pages

  2. KOOLCOM

    2 Pages

  3. DFRE-P

    1 Pages

  4. PE-45

    1 Pages

  5. Acoustic

    2 Pages

  6. 36-STE

    2 Pages

  7. S26

    1 Pages

  8. 20-SH/21-SH

    1 Pages

  9. 20-DH/21-DH

    1 Pages