SCDC Smoke dampers
Open the catalog to page 1Series SCDC SCDC Smoke Evacuation Damper CONTENTS Description 2
Open the catalog to page 2Series SCDC SCDC Smoke Evacuation Damper Description KOOLAIR’s SCDC rectangular smoke evacuation damper is composed of a single body of heat-resistant material, with steel flanges on either side (optional) to facilitate mounting in rectangular ducts, and a single heat resistant closing blade. Tunnel type damper for in-line installation in horizontal ducts for use with both supply and extract, certified according to EN 136610, classified according to EN 13501-4; EI 120 (ved i o) S 1500 AA multi. The SCDC smoke damper has the 0370 - CPR - 2600 certificate of constancy of performance according...
Open the catalog to page 3Series SCDC SCDC Smoke Evacuation Damper Connections Operating mechanism electrical connections FCU: safety position (end of run) one-pole contact. DCU: waiting position (start of run) one-pole contact. FCB: safety position (end of run) two-pole contact. DCB: waiting position (start of run) two-pole contact. - Manual reset, activated by electric coil (CE and NF marking). 24 V DC. electric shunt release coil. 48V DC electric shunt release coil 24V AC electric shunt release coil 48V AC electric shunt release coil COIL (Supply type) Option to incorporate two start of run limit switches (DCU,...
Open the catalog to page 4Series SCDC SCDC Smoke Evacuation Damper Connections - Automatic activation and reset by servomotor (CE Marking): SCDC smoke extract dampers are activated and reset by means of a servomotor with a supply voltage of 24 V AC/DC (model BLE24) or 230 V AC (model BLE230). These motors include start and end of run limit switches to monitor the opening/closing status of the damper. • Activated by shunt release coil and reset with electric servomotor (CE and NF marking): 24 V DC electric shunt release coil. 48V DC electric shunt release coil 24V AC electric shunt release coil 48V AC electric shunt...
Open the catalog to page 5Series SCDC SCDC SMOKE DAMPER FREE AREA TABLE dm2
Open the catalog to page 6Series SCDC SCDC Smoke Evacuation Damper Selection Chart SCDC Vp-ΔPest 100 90 80 70 Key Vp= damper air velocity in m/s. ΔPest= static pressure loss across the damper in Pa. Selection example: To calculate the static pressure loss across a damper for a given flow rate Q(m3/h) the air velocity Vp(m/s) is calculated in relation to the free area Al (dm2) of the damper as set out in the above table “Free area table in dm2” using the formula Vp=(Q/Al)/36. By entering this velocity in the previous table, the static pressure loss is obtained ΔPest. Example: for a flow rate of 2500 m3/h in a 500x300...
Open the catalog to page 7Series SCDC SCDC Smoke Evacuation Damper Installation The approval and the certification requirements for the installation of the damper are shown below. DAMPER BODY DUCT SCREW SPAX ABC Ø5.5X50 SCDC damper application in installations which employ ductwork different from that which has been submitted for certification testing: SCDC smoke control dampers, for use in multi-compartment systems (multi), are applicable in ducts that are tested in accordance with EN1366-8 as appropriate for each particular case or manufactured from materials with the same density or greater thickness than those...
Open the catalog to page 8Series SCDC SCDC Smoke Evacuation Damper Coding Damper model (see table p. 5 Declared Performance) Activation. Components f + MOTOR-BLE24 + MOTOR-BLE230 + SHUNT RELEASE 24 V DC + ER/SR LS + SHUNT RELEASE 48 V DC + ER/SR LS + SHUNT RELEASE 24 V AC + FC/PC + SHUNT RELEASE 48 V AC + FC/PC + SHUNT RELEASE 24 V DC + FC/PC + MOTOR RESET-BL24/48 + SHUNT RELEASE 48 V DC + FC/PC + MOTOR RESET-BL24/48 + SHUNT RELEASE 24 V AC + FC/PC + MOTOR RESET-BL24/48 + SHUNT RELEASE 48 V AC + FC/PC + MOTOR RESET-BL24/48 Accessories r - C1+C2 (rectangular collars on both sides of damper) - C1 (rectangular collar...
Open the catalog to page 9Series SCDC THIS CATALOG IS INTELLECTUAL PROPERTY. The partial or total reproduction of its contents is forbidden without the express and authoritative authorisation of KOOLAIR, S.A. CEN-SCDC-1117-00
Open the catalog to page 10KOOLAIR, S.A. Calle Urano, 26 Poligono industrial nº 2 – La Fuensanta 28936 Móstoles - Madrid - (España) Tel: +34 91 645 00 33 Fax: +34 91 645 69 62 e-mail: info@koolair.com
Open the catalog to page 11All KOOLAIR S.A catalogs and technical brochures
-
series FLOOR
23 Pages
-
series Dampers 100-2
21 Pages
-
FIRE protection
2 Pages
-
KOOLCOM
2 Pages
-
DFRE-P
1 Pages
-
PE-45
1 Pages
-
Acoustic
2 Pages
-
Series 100-200 Dampers
18 Pages
-
VENTILATION HOODS
6 Pages
-
Series SF Fire dampers
35 Pages
-
36-STE
2 Pages
-
DTP-GT Multi-nozzles diffusers
15 Pages
-
DTP Multi-nozzles diffusers
14 Pages
-
Koolair product range
2 Pages
-
Technical Selection Guide
145 Pages
-
Bypass terminal units – KMSR
15 Pages
-
Terminal units with fan – HVFS
12 Pages
-
Air Volume Boxes – Series KD
7 Pages
-
Measurement Station – EM
6 Pages
-
Passive chilled beams – VPK
9 Pages
-
Induction terminal units – IHK
20 Pages
-
Square diffusers – Series 50
22 Pages
-
Multinozzles diffusers – DF49MT3
20 Pages
-
Long-throw nozzles – DF 89
19 Pages
-
Long-throw nozzles – DF 49
19 Pages
-
Linear grilles – Series 30
19 Pages
-
S26
1 Pages
-
21-DVC/21-DVR
1 Pages
-
21-SVC/21-SVR
1 Pages
-
20-SH/21-SH
1 Pages
-
20-DH/21-DH
1 Pages
-
Circular diffusers – DCL
2 Pages
-
Extract valves – Series GPD
8 Pages
-
Circular diffusers – Series 40.1
31 Pages
-
Security grilles – KSG
12 Pages
-
Return grilles – Series 20.2
19 Pages
-
Supply grilles – Series 26
10 Pages
-
Regulating dampers
18 Pages
-
Silencers – Series SK
25 Pages
-
Linear Diffusers – Series 70.1
26 Pages
-
Circular diffuser – Series 40.1
31 Pages
-
Supply grilles – Series 20.1
19 Pages