1. Catalogs
  2. KOOLAIR S.A
  3. Regulating dampers
video corpo

Regulating dampers

Regulating dampers
1 / 18 PagesView full catalog

Regulating dampers

Product catalog summary
Overview
Circular Regulating Dampers (CRD) are crucial for air installations, used to balance and shut off airflow. Made from galvanized sheet metal, they come in various models with distinct features and applications.
Types of Dampers
  • CRC-M: Equipped with a locking quadrant mechanism for visual position indication and a positive seal.
  • CRC-E: Operated with a simple handle, also providing a positive seal.
  • CCC: Similar to CRC-E but lacks a positive seal.
Product Codes and Dimensions
Dampers are coded by the duct diameter they fit, e.g., CCC 200 for a 200 mm duct. Dimensions vary by model, with specified nominal lengths and diameters.
Technical Data
Includes detailed technical data such as sound pressure levels and noise data for various damper sizes and airflow rates. Sound pressure levels are provided in dB(A) for inlet pressures from 100 to 1000 Pa, assuming a 10 dB/Octave attenuation in the outlet duct, diffuser, and room.
Sound Pressure Levels
Tables provide regenerated and radiated noise levels across octave bands (63 to 8000 Hz) for each damper size and airflow rate, essential for assessing acoustic impact in HVAC systems.
Conclusion
The document offers comprehensive specifications and technical data for selecting and implementing circular regulating dampers in HVAC systems, focusing on acoustic performance and dimensional details.
Introduction
The document details KOOLAIR CRR volume control dampers for flow and pressure control in HVAC installations. These rectangular units are made of galvanized steel and vary by operating mechanisms and air tightness levels.
Models
  • CRR-MT: Features servo drive-based slat operation with options for opened/closed, three-setting, or proportional operation, includes a tightness seal, and operates on 24V or 220V AC.
  • CRR-M: Manually operated with an easy-to-use control section indicating slat opening, includes a tightness seal.
  • CRR-E: Operated by a simple control (handle or wing nut) and includes a tightness seal.
  • CRR: Similar to CRR-E but without a tightness seal.
Technical Data
Includes a sound power and pressure loss chart for dampers with an area of 0.1 m2, providing data on sound power levels and pressure loss based on front air velocity and damper opening percentage. Correction factors are available for different cross-sections.
Dimensions and Identification
Standard dimensions are available, with a coding system for identifying different models and configurations. An example code is provided for clarity.
Contact Information
KOOLAIR, S.A. is located in Móstoles, Madrid, Spain. Contact details include a phone number, fax, email, and website.
See more

Catalog excerpts

Regulating dampers-1

series REGULATING DAMPERS

 Open the catalog to page 1
Regulating dampers-2

CONTENTS Regulating dampers CRC-M, CRC-E and CCC 4 Regulating dampers CRR, CRR-E, CRR-M and CRR-MT 13 Product codes and dimensions 14

 Open the catalog to page 2
Regulating dampers-3

Circular regulating dampers types CRC-M, CRC-E and CCC Description Circular Regulating Dampers are used to balance air installations, also these dampers can be used as shutoff dampers. Circular regulating dampers are manufactured in Galvanised sheet metal. Damper CRC-M Models There are 3 different types of circular regulating dampers; CRC-M: Circular Regulating Dampers made from a steel cylinder made in galvanised sheet metal, it is operated by means of a locking quadrant mechanism, which gives us a visual indication of the damper position, this model provides a positive seal. CRC-E: Circular...

 Open the catalog to page 3
Regulating dampers-4

Type CRC-E NOMINAL

 Open the catalog to page 4
Regulating dampers-5

Executions. Dimensions Type CRC-M and CRC-MT

 Open the catalog to page 5
Regulating dampers-6

Sound Pressure Levels in dB(A)

 Open the catalog to page 6
Regulating dampers-9

Dampers Technical data Damper Regenerated noise

 Open the catalog to page 9
Regulating dampers-10

DampersQuick selection tablesValue of the Sound Power of the regenerated noise (dB) for the circular regulating dampers in the different Octave bands from 63 to 8000 Hz. Damper Radiated noise

 Open the catalog to page 10
Regulating dampers-11

Dampers Quick selection tables Damper Radiated noise

 Open the catalog to page 11
Regulating dampers-12

Volume control dampers, CRR series Description The KOOLAIR CRR volume control dampers are rectangular units to be used for flow and pressure control in HVAC installations. The dampers are fitted with a single slat commanded by a central shaft and are manufactured of galvanized steel sheet. Models There are four types of rectangular volume control dampers, according to the operating mechanism included and the degree of air tightness provided: CRR-MT: Rectangular volume control damper manufactured of galvanized steel sheet, with servo drive-based slat operation (opened/closed, three-setting operation,...

 Open the catalog to page 12
Regulating dampers-13

Dampers Product codes CRR. Dimensions LxH (mm). CRR-E Dimensions LxH (mm). CRR-M Dimensions LxH (mm). CRR-MT Dimensions LxH (mm). Note: Specify servo drive type and power Identification The damper identification will be coded according to the nomenclature listed in the adjacent table. Coding example: CRR-MT, 500x200 with open/closed servo drive, 24V DC power. Executions. Dimensions The dimensions listed below are standard for all damper models in the series. NOMINAL DIMENSIONS (AIR FLOW AREA), in mm

 Open the catalog to page 13
Regulating dampers-14

Executions. Dimensions - CRR-E model NOMINAL HEIGHT NOMINAL LENGTH - CRR-M model MANUAL CONTROL NOMINAL HEIGHT NOMINAL LENGTH

 Open the catalog to page 14
Regulating dampers-15

Executions. Dimensions - CRR-MT model NOMINAL HEIGHT NOMINAL LENGTH Technical data Sound power and pressure loss chart, for % damper opening (20% to 100%) The following chart corresponds to volume control dampers with an area of 0.1 m2. For other cross-sections, please use the correction factor listed in the table on next page. % damper opening Symbols V (m/s): Front air velocity through the damper, in m/s Pest (Pa): Pressure drop in damper, in Pa LWA [dB(A)]: Sound power level, in dB(A)

 Open the catalog to page 15
Regulating dampers-16

DampersTechnical data Technical data table. Sound power level and pressure loss The following table can be used to obtain the sound power level (in dB/octave), from a front air flow velocity and a degree of damper opening (pressure loss, in Pa). The data shown in the following table are for dampers with an area of 0.1 m . For other cross-sections, please use the correction factor listed further below on this page.

 Open the catalog to page 16
Regulating dampers-17

THIS CATALOGUE IS INTELLECTUAL PROPERTY, Reproduction, either partial or total, by any means, including electronic, is prohibited without prior written authorisation from KOOLAIR, S.A. CIN-CRC-0515-00

 Open the catalog to page 17
Regulating dampers-18

KOOLAIR, S.A. Calle Urano, 26 Poligono industrial nº 2 – La Fuensanta 28936 Móstoles - Madrid - (España) Tel: +34 91 645 00 33 Fax: +34 91 645 69 62 e-mail: [email protected]

 Open the catalog to page 18

All KOOLAIR S.A catalogs and technical brochures

  1. series FLOOR

    23  Pages

  2. KOOLCOM

    2  Pages

  3. DFRE-P

    1  Page

  4. PE-45

    1  Page

  5. Acoustic

    2  Pages

  6. 36-STE

    2  Pages

  7. S26

    1  Page

  8. 20-SH/21-SH

    1  Page

  9. 20-DH/21-DH

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.