Catalog excerpts
40.3 Fixed blades swirl diffusers
Open the catalog to page 1Technical data. Selection tables 14
Open the catalog to page 2Fixed blade swirl diffuser Swirl difuser DFRE Fixed blade swirl diffusers, inserted in square plate, specially designedto be adapted into a false or plasterboard ceilings. Made of sheet steel and finished inwhite RAL 9010, others special finishes are available upon request. The circular plenum incorporates a VCD on the spigot made on perforate plate; it can be accessible from the room upon request. On request, the plenum can be supplied insulating material. DFRE Swirl difuser DFRE-C Circular fixed blade swirl diffuser. These diffusers are inserted in square panels for adaption to to “lay...
Open the catalog to page 3Fixed blade swirl diffuser Swirl difuser DAFC Fixed curved blade swirl diffuser. These diffusers are inserted in square panels for adaption to “lay in” tile replacements ceilings. Made of steel sheet, coated in white RAL 9010. Special finishes available upon request. The plenum box incorporates in the spigot a manually operated volume flow damper made of perforated sheet. Upon request, plenum boxes can be provided with interior isolation. DAFC DV Swirl difuser DAFC-C Circular fixed curved blade swirl diffuser. These diffusers are inserted in square panels for adaption to “lay in” tile...
Open the catalog to page 4Fixed blade swirl diffuser Swirl difuser DAFT Fixed inclined blade swirl diffusers, integrated into square plate, specially designed to be adapted into false or plasterboard ceilings. Made of sheet steel and finished in white RAL 9010, others special finishes are available upon request. The circular plenum incorporates a VCD on the spigot made on perforate plate; it can be accessible from the room upon request. On request, the plenum can be supplied insulating material. DAFT Swirl difuser DAFT-C Fixed inclined blade swirl diffusers integrated into circular plate, specially designed to be...
Open the catalog to page 5r □□□□□! □□□□□□□ =• □□□ «= □□□□□□□ k□□□□□A V uuuS
Open the catalog to page 6Models and dimensions: DFRE-GR-PR DIMENSIONS
Open the catalog to page 9f □□□□□! □□□□□□□ =■ □□□ 1= □□□□□□□ L□□□□□A V nnuS
Open the catalog to page 10Series 40.3 Models and dimensions: DAFC-C DIMENSIONS
Open the catalog to page 11Series 40.3Models and dimensions: HDPR / HDPR-C HDPR
Open the catalog to page 12Series 40.3 Models and dimensions: DAFT DIMENSIONS
Open the catalog to page 13Series 40.3Models and dimensions: DFRT DIMENSIONS
Open the catalog to page 14Series 40.3Technical data. Selection tables: DFRE/Q/C Q velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Lw Sound power level, in
Open the catalog to page 15Series 40.3Technical data. Selection tables: DFRE-GR + PL Q X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Lw Sound power level, in dB(A)
Open the catalog to page 16Series 40.3Technical data. Selection tables: DFRE-GR-PR Q SYMBOLS Ak Effective area in m2 X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Lw Sound power level, in dB(A)
Open the catalog to page 17Series 40.3Technical data. Selection tables: DAFC/Q/C DAFC SYMBOLS Ak Effective area in m2 velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Lw Sound power level, in
Open the catalog to page 18Series 40.3Technical data. Selection tables: HDPR/C HDPR X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Lw Sound power level, in dB(A)
Open the catalog to page 19Series 40.3Technical data. Selection tables: DAFT/C DAFT VZ Velocity in occupied area, in m/s X Distance between diffuser axes, in m. Pt Total pressure drop, in Pa Lw Sound power level, in dB(A)
Open the catalog to page 20Series 40.3Technical data. Selection tables: DFRT/C DIFUSOR DFRT VZ Velocity in occupied area, in m/s X Distance between diffuser axes, in m. Pt Total pressure drop, in Pa Lw Sound power level, in dB(A)
Open the catalog to page 21Series 40.3Product code The product code shown below is used to define both the diffuser as well as the plenum: Example: DFRE-Q- E-0315 RAL 9010 Fixed blade swirl diffuser in plate size 600 x 600 mm, size 315 mm coated in white RAL 9010.
Open the catalog to page 22THIS CATALOGUE IS INTELLECTUAL PROPERTY. Reproduction, either partial or total, by any means, including electronic, is prohibited without prior written authorisation from KOOLAIR, S.A. CEN-40.3-0112-00
Open the catalog to page 23KOOLAIR, S.A. Calle Urano, 26 Poligono industrial nº 2 – La Fuensanta 28936 Móstoles - Madrid - (España) Tel: +34 91 645 00 33 Fax: +34 91 645 69 62 e-mail: info@koolair.com
Open the catalog to page 24All KOOLAIR S.A catalogs and technical brochures
-
series FLOOR
23 Pages
-
series Dampers 100-2
21 Pages
-
FIRE protection
2 Pages
-
KOOLCOM
2 Pages
-
DFRE-P
1 Pages
-
PE-45
1 Pages
-
Acoustic
2 Pages
-
Series 100-200 Dampers
18 Pages
-
VENTILATION HOODS
6 Pages
-
Series SF Fire dampers
35 Pages
-
Series SCDC Smoke dampers
11 Pages
-
36-STE
2 Pages
-
DTP-GT Multi-nozzles diffusers
15 Pages
-
DTP Multi-nozzles diffusers
14 Pages
-
Koolair product range
2 Pages
-
Technical Selection Guide
145 Pages
-
Bypass terminal units – KMSR
15 Pages
-
Terminal units with fan – HVFS
12 Pages
-
Air Volume Boxes – Series KD
7 Pages
-
Measurement Station – EM
6 Pages
-
Passive chilled beams – VPK
9 Pages
-
Induction terminal units – IHK
20 Pages
-
Square diffusers – Series 50
22 Pages
-
Multinozzles diffusers – DF49MT3
20 Pages
-
Long-throw nozzles – DF 89
19 Pages
-
Long-throw nozzles – DF 49
19 Pages
-
Linear grilles – Series 30
19 Pages
-
S26
1 Pages
-
21-DVC/21-DVR
1 Pages
-
21-SVC/21-SVR
1 Pages
-
20-SH/21-SH
1 Pages
-
20-DH/21-DH
1 Pages
-
Circular diffusers – DCL
2 Pages
-
Extract valves – Series GPD
8 Pages
-
Circular diffusers – Series 40.1
31 Pages
-
Security grilles – KSG
12 Pages
-
Return grilles – Series 20.2
19 Pages
-
Supply grilles – Series 26
10 Pages
-
Regulating dampers
18 Pages
-
Silencers – Series SK
25 Pages
-
Linear Diffusers – Series 70.1
26 Pages
-
Circular diffuser – Series 40.1
31 Pages
-
Supply grilles – Series 20.1
19 Pages