Catalog excerpts
DTP-GT Multi-nozzles diffusers
Open the catalog to page 1v. Description The DTP-GT, multi-nozzles diffuser is designed to solve any diffusion problem, either conventional or specific, capable of being adapted to the multiple and different problems generated by a right air diffusion installation. We are facing a versatile product with a different aesthetic and interior design needs, with low noise and excellent performance in the air diffusion. Composed of small nozzles individually adjustable in all directions. The fact of being adjustable, allows to adjut them on site, solving those little situations that sometimes occur, in which the excess or...
Open the catalog to page 3Fixing the diffuser to the plenum is made by a single central screw, in the case of rem
Open the catalog to page 4Fixing the diffuser to the plenum is made by a single central screw, in the case of removable plenum (dimensions shown).
Open the catalog to page 5Fixing the diffuser to the plenum is made by a single central screw, in the case of removable plenum (dimensions shown).
Open the catalog to page 6Fixing the diffuser to the plenum is made by mounting clips, in the case of removable plenum (dimensions shown). There is also the possibility of fixed plenum (for dimensions see the sales department).
Open the catalog to page 7For the technical data, both supply and return, please use the technical data appearing in the DTP-GT-Q tables.
Open the catalog to page 8X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Sound power level, in dB(A)
Open the catalog to page 9X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Sound power level, in dB(A)
Open the catalog to page 10Series DTP-GTSelection tables: DTP-GT-C / DTP-GT-C-Q DTP-GT-CQ/DTP-GT-C X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Sound power level, in dB(A)
Open the catalog to page 11Series DTP-GTSelection tables: DTP-GT-L DTP-GT-L 1D v.f \SYMBOLS Vk Effective velocity in m/s X Throw for maximum velocity in occupied area of 0,25 m/s, AT= 0 K and an installation height of 3 m, considering Coanda effect, in m Pt Total pressure drop, in Pa Sound power level, in dB(A)
Open the catalog to page 12Series DTP-GT Product code The product code shown below is used to define both the diffuser as well as the plenum: Multi-nozzles diffuser Square platte Square platte 594 x 594 Circular platte Linear Square platte 594 x 594 in circular distribution Supply / Return One direction Two directions Three directions Four directions Radial --- Without plenum PF Fixed plenum without damper PD Removable plenum without damper PF-C Fixed plenum with damper PD-C Removable plenum with damper PFA Insulated fixed plenum without damper PDA Insulated removable plenum without damper PFA-C...
Open the catalog to page 13Series DTP-GT THIS CATALOGUE IS INTELLECTUAL PROPERTY. Reproduction, either partial or total, by any means, including electronic, is prohibited without prior written authorisation from KOOLAIR, S.A. CIN-DTP-GT-0516-00
Open the catalog to page 14KOOLAIR, S.A. Calle Urano, 26 Poligono industrial nº 2 – La Fuensanta 28936 Móstoles - Madrid - (España) Tel: +34 91 645 00 33 Fax: +34 91 645 69 62 e-mail: info@koolair.com
Open the catalog to page 15All KOOLAIR S.A catalogs and technical brochures
-
series FLOOR
23 Pages
-
series Dampers 100-2
21 Pages
-
FIRE protection
2 Pages
-
KOOLCOM
2 Pages
-
DFRE-P
1 Pages
-
PE-45
1 Pages
-
Acoustic
2 Pages
-
Series 100-200 Dampers
18 Pages
-
VENTILATION HOODS
6 Pages
-
Series SF Fire dampers
35 Pages
-
Series SCDC Smoke dampers
11 Pages
-
36-STE
2 Pages
-
DTP Multi-nozzles diffusers
14 Pages
-
Koolair product range
2 Pages
-
Technical Selection Guide
145 Pages
-
Bypass terminal units – KMSR
15 Pages
-
Terminal units with fan – HVFS
12 Pages
-
Air Volume Boxes – Series KD
7 Pages
-
Measurement Station – EM
6 Pages
-
Passive chilled beams – VPK
9 Pages
-
Induction terminal units – IHK
20 Pages
-
Square diffusers – Series 50
22 Pages
-
Multinozzles diffusers – DF49MT3
20 Pages
-
Long-throw nozzles – DF 89
19 Pages
-
Long-throw nozzles – DF 49
19 Pages
-
Linear grilles – Series 30
19 Pages
-
S26
1 Pages
-
21-DVC/21-DVR
1 Pages
-
21-SVC/21-SVR
1 Pages
-
20-SH/21-SH
1 Pages
-
20-DH/21-DH
1 Pages
-
Circular diffusers – DCL
2 Pages
-
Extract valves – Series GPD
8 Pages
-
Circular diffusers – Series 40.1
31 Pages
-
Security grilles – KSG
12 Pages
-
Return grilles – Series 20.2
19 Pages
-
Supply grilles – Series 26
10 Pages
-
Regulating dampers
18 Pages
-
Silencers – Series SK
25 Pages
-
Linear Diffusers – Series 70.1
26 Pages
-
Circular diffuser – Series 40.1
31 Pages
-
Supply grilles – Series 20.1
19 Pages