Displacement diffusers
Open the catalog to page 1Displacement Diffuser Units LADES Long-Throw Displacement Diffuser Unit 29-30 Selection Examples, Results and Correction Factors 31-32
Open the catalog to page 2S-90 Series S-90 Series Displacement Diffusers S-90 Series Overview The S-90 diffusers are displacement units for floor installation. The unit includes upper and lower covers and a perforated air distribution face plate. Connections can be made through the upper or lower cover. The units are of galvanised steel sheet construction with aluminium sections and include an air equalising plate (painted in black) inside, as well as static pressure measurement to obtain the supply flow rate. The standard finish is RAL 9010 white paint, although any RAL colour is available upon...
Open the catalog to page 3S-90-C Model - Round Dimensions The S-90-C diffuser is a cylindrical displacement unit that supplies air at a low velocity to the habitable area. Optional accessories include a plinth and trim. UPPER COVER BAND FASTENER FOR DECORATIVE SECTION LOWER COVER REMOVABLE TRIM SECTION PRESSURE SENSOR DECORATIVE PLINTH DIMENSIONS Size
Open the catalog to page 4S-90-C Model - Round Technical data Quick selection table S-90-C QUICK SELECTION TABLE The air flow, pressure drop and horizontal throw of the air jet are listed below for a velocity of 0.20 m/s in the occupied area, based on a specific sound level. S-90-C These charts allow the sound level and pressure drop data to be obtained from the supply flow rate. S-90-C Symbols: Q (m3/h) Air flow per displacement unit LwA(dBA) Sound power level
Open the catalog to page 5S-90-C Model - Round Throw data The selection charts shown allow the horizontal throw of the air jet to be obtained from the supply flow rate, when the velocity in the occupied area is 0.20 m/s. Selection charts. Air flow per displacement unit X0.20(m) Horizontal throw of the air jet, when the velocity in the occupied area is 0.20 m/s for a temperature difference of T = -3 ºC
Open the catalog to page 6S-90-SC Model - Semicircular Dimensions The S-90-SC diffuser is a semicircular displacement unit that supplies the air at low velocity to the habitable area. Optional accessories include a plinth and trim.
Open the catalog to page 7S-90-SC Model - Semicircular Technical data Quick selection table The air flow, pressure drop and horizontal throw of the air jet are listed below for a velocity of 0.20 m/s in the occupied area, based on a specific sound level. Pressure drop and sound level selection charts S-90-SC 25 These charts allow the sound level and pressure drop data to be obtained from the supply flow rate. Symbols: Q (m3/h) Air flow per displacement unit ΔP (Pa) Pressure drop LwA(dBA) Sound power level
Open the catalog to page 8S-90-SC Model - Semicircular Selection charts. Throw data S-90-SC Ø 160 The selection charts shown allow the horizontal throw of the air jet to be obtained from the supply flow rate, when the velocity in the occupied area is 0.20 m/s. Air flow per displacement unit X0.20(m) Horizontal throw of the air jet, when the velocity in the occupied area is 0.20 m/s for a temperature difference of T = -
Open the catalog to page 9S-90-CC Model - Quadrant Dimensions The S-90-CC diffuser is a quadrant displacement unit that supplies the air at low velocity to the habitable area. Optional accessories include a plinth and trim. UPPER COVER BAND FASTENER FOR DECORATIVE SECTION LOWER COVER REMOVABLE TRIM SECTION PRESSURE SENSOR DECORATIVE PLINTH
Open the catalog to page 10S-90 Series S-90-CC Model - Quadrant Technical data Quick selection table S-90-CC QUICK SELECTION TABLE The air flow, pressure drop and horizontal throw of the air jet are listed below for a velocity of 0.20 m/s in the occupied area, based on a specific sound level. S-90-CC These charts allow the sound level and pressure drop data to be obtained from the supply flow rate. S-90-CC Symbols: Q (m3/h) Air flow per displacement unit Lw^(dBA) Sound power level
Open the catalog to page 11S-90-CC Model - Quadrant Selection charts. Throw data S-90-CC The selection charts shown allow the horizontal throw of the air jet to be obtained from the supply flow rate, when the velocity in the occupied area is 0.20 m/s. Air flow per displacement unit X0.20(m) Horizontal throw of the air jet, when the velocity in the occupied area is 0.20 m/s for a temperature difference of T = -3 ºC
Open the catalog to page 1212 S-90 Series S-90-R Model - Rectangular Dimensions The S-90-R diffuser is a rectangular displacement unit that supplies the air at low velocity to the habitable area. Optional accessories include a plinth and trim.
Open the catalog to page 13S-90 SeriesS-90-R Model - RectangularTechnical data Quick selection table The air flow, pressure drop and horizontal throw of the air jet are listed below for a velocity of 0.20 m/s in the occupied area, based on a specific sound level. These charts allow the sound level and pressure drop data to be obtained from the supply flow rate. Symbols: Q (m3/h) Air flow per displacement unit Lw^(dBA) Sound power level
Open the catalog to page 14S-90-R Model - Rectangular Pressure drop and sound level selection charts (continuation) These charts allow the sound level and pressure drop data to be obtained from the supply flow rate. Air flow per displacement unit Pressure drop Sound power l
Open the catalog to page 15S-90-R Model - Rectangular Selection charts. Throw data S-90-R The selection charts shown allow the horizontal throw of the air jet to be obtained from the supply flow rate, when the velocity in the occupied area is 0.20 m/s. Air flow per displacement unit X0.20(m) Horizontal throw of the air jet, when the velocity in the occupied area is 0.20 m/s for a temperature difference of T = -3 ºC
Open the catalog to page 16S-90 Series S-90-R3 Model - 3-Way Rectangular Dimensions The S-90-R-3 diffuser is a rectangular displacement unit that supplies the air at low velocity to the habitable area in three directions. Optional accessories include a plinth and trim. DIMENSIONS Size
Open the catalog to page 17S-90 SeriesS-90-R3 Model - 3-Way RectangularTechnical data Quick selection table The air flow, pressure drop and horizontal throw of the air jet are listed below for a velocity of 0.20 m/s in the occupied area, based on a specific sound level. These charts allow the sound level and pressure drop data to be obtained from the supply flow rate. Symbols: Q (m3/h) Air flow per displacement unit Lw^(dBA) Sound power level
Open the catalog to page 18All KOOLAIR S.A catalogs and technical brochures
-
series FLOOR
23 Pages
-
series Dampers 100-2
21 Pages
-
FIRE protection
2 Pages
-
KOOLCOM
2 Pages
-
DFRE-P
1 Pages
-
PE-45
1 Pages
-
Acoustic
2 Pages
-
Series 100-200 Dampers
18 Pages
-
VENTILATION HOODS
6 Pages
-
Series SF Fire dampers
35 Pages
-
Series SCDC Smoke dampers
11 Pages
-
36-STE
2 Pages
-
DTP-GT Multi-nozzles diffusers
15 Pages
-
DTP Multi-nozzles diffusers
14 Pages
-
Koolair product range
2 Pages
-
Technical Selection Guide
145 Pages
-
Bypass terminal units – KMSR
15 Pages
-
Terminal units with fan – HVFS
12 Pages
-
Air Volume Boxes – Series KD
7 Pages
-
Measurement Station – EM
6 Pages
-
Passive chilled beams – VPK
9 Pages
-
Induction terminal units – IHK
20 Pages
-
Square diffusers – Series 50
22 Pages
-
Multinozzles diffusers – DF49MT3
20 Pages
-
Long-throw nozzles – DF 89
19 Pages
-
Long-throw nozzles – DF 49
19 Pages
-
Linear grilles – Series 30
19 Pages
-
S26
1 Pages
-
21-DVC/21-DVR
1 Pages
-
21-SVC/21-SVR
1 Pages
-
20-SH/21-SH
1 Pages
-
20-DH/21-DH
1 Pages
-
Circular diffusers – DCL
2 Pages
-
Extract valves – Series GPD
8 Pages
-
Circular diffusers – Series 40.1
31 Pages
-
Security grilles – KSG
12 Pages
-
Return grilles – Series 20.2
19 Pages
-
Supply grilles – Series 26
10 Pages
-
Regulating dampers
18 Pages
-
Silencers – Series SK
25 Pages
-
Linear Diffusers – Series 70.1
26 Pages
-
Circular diffuser – Series 40.1
31 Pages
-
Supply grilles – Series 20.1
19 Pages