Open the catalog to page 2Description The circular constant volume regulator type RCCK is a control element which works independently of the pressure without an external power supply. It can be regarded as a self-actuating duct damper, as it delivers a required volume of air regardless of changes in system pressure. In consequence, the controller overcomes the need for system balancing and ensures constant air flow in service.The RCCK incorporates an adjustment device that allows to modify manually on site the air-flow pre-adjusted at the factory. 1. Adjusting box 2. Casing 3. Regulation blade 4. Indicator of adjusted...
Open the catalog to page 3Dimensions Dimensions The RCCK are designed to pressure connection directly to the duct, as its diameters are standardized as per ISO Norms, they can be installed either in vertical or horizontal position. DIMENSIONS EN mm. RCCK, without insulation Uninsulated constant air volume regulator with silencer ASK-1 RCCK-D, with insulation
Open the catalog to page 4Insulated constant air volume regulator with silencer ASK-1 MM Con MM Para MM Selection tables TABLE 1 (Regenerated noise) and TABLE 3 (Radiated noise) In these tables the following values are showed for each size with different air-flow and static pressure at the inlet of the regulator. LA. Sound pressure level in the room expressed in dB(A).We have considered an attenuation of duct, diffuser as well as the room´s one of 8 dB(A)/Octave. TABLE 2 (Regenerated noise Spectrum) In this table the following values are showed for each size with different air-flow and static pressure at the inlet of...
Open the catalog to page 5Selection tables Table 2
Open the catalog to page 7Selection tables Table 3
Open the catalog to page 9Series RCC Selection tables Table 4
Open the catalog to page 11Series RCCRadiated noise. Correction factors for versions with external insulation. PRESSURE, ACCURACY AND REGULATING BAND The regulator RCCK operates reliably from a minimum pressure difference, which depends on the air velocity (see diagram below), to a maximum pressure difference of 1000 Pa. The accuracy of the adjusted air-flow is within a tolerance of +-10%. Accuracy will be lower than indicated if the air flow profile is not uniform or is distorted by bends, sharp edges or bottlenecks that can disturb the air flow uniformity in the duct. We recommended, therefore to optimized the work condition...
Open the catalog to page 12Adjustment and installation Adjustment 1 - Control damper box setting control 2 - Part marking 3 - Label airflow graduation 4 - Mechanism box Steps to set the flowrate on the control damper: Turn the setting control (1) on the mechanism box side (4) until the marking part (3) is set to the required air flowrate (2). The RCCK are designed to pressure connection directly to the duct, as its diameters are standardized as per ISO Norms, they can be installed either in vertical or horizontal position. The tightness is getting by means of rolling rubbers ring seals in both ends. The adjustment device...
Open the catalog to page 13Series RCCConstant air volume regulator RCQK 1. Adjusting box 2. Scale 3. Indicator of adjustedair flow 4. Casing 5. Control damper box setting control 6. Regulation blade Description The rectangular constant volume regulator type RCQK is a control element which works independently of the pressure without an external power supply. It can be regarded as a self-actuating duct damper, as it delivers a required volume of air regardless of changes in system pressure. In consequence, the controller overcomes the need for system balancing and ensures constant air flow in service. The RCQK incorporates...
Open the catalog to page 1414 Series RCC Dimensions Dimensions The RCQK are designed to fit standard rectangular duct. Flange connection 20 mm with 4 holes in the corners. Upon request can be made in other sizes. Type 1 Uninsulated constant air volume regulator with silencer PAK with central baffle
Open the catalog to page 15Dimensions Uninsulated constant air volume regulator with silencer PAK without central baffle Insulated constant air volume regulator with silencer PAK with central baffle
Open the catalog to page 16Dimensions Insulated constant air volume regulator with silencer PAK without central baffle Selection tables TABLE 5 (Regenerated noise) and TABLE 7 (Radiated noise) In these tables the following values are showed for each size with different air-flow and static pressure at the inlet of the regulator. LA. Sound pressure level in the room expressed in dB(A).We have considered an attenuation of duct, diffuser as well as the room´s one of 8 dB(A)/Octave. TABLE 6 (Regenerated noise Spectrum) In this table the following values are showed for each size with different air-flow and static pressure at...
Open the catalog to page 17Selection tables Table 5 RCQK
Open the catalog to page 18Selection tables RCQK
Open the catalog to page 19Series RCCSelection tables Table 6
Open the catalog to page 20Series RCC Selection tables Table 6
Open the catalog to page 21Series RCCSelection tables Table 6
Open the catalog to page 22Series RCC Selection tables Table 6
Open the catalog to page 2323 Selection tables Table 7 RCQK
Open the catalog to page 24Selection tables RCQK
Open the catalog to page 25Series RCCSelection tables Table 8
Open the catalog to page 26Series RCC Selection tables Table 8
Open the catalog to page 27Series RCCSelection tables Table 8
Open the catalog to page 28Series RCC Selection tables Table 8
Open the catalog to page 29Series RCCRadiated noise. Correction factors for versions with external insulation. RCQK-D PRESSURE, ACCURACY AND REGULATING BAND OPERATING TEMPERATURE The regulator RCQK operates reliably from a minimum The standard regulator RCQK operates within a pressure difference, which depends on the air velocity (see temperature range from -20° C y + 80° C. diagram below), to a maximum pressure difference of 1000 Pa. The accuracy of the adjusted air-flow is within a tolerance of +-10%. Accuracy will be lower than indicated if the air flow profile is not uniform or is distorted by bends, sharp edges...
Open the catalog to page 30Adjustment and installation Adjustment 1 - Control damper box setting control 2 - Part marking 3 - Label airflow graduation 4 - Mechanism box Steps to set the flowrate on the control damper: Turn the setting control (1) on the mechanism box side (4) until the marking part (3) is set to the required air flowrate (2). The RCQK are designed to fit standard rectangular duct. Upon request can be made in other sizes. Flange connection 20 mm with 4 holes in the corners. They can be installed either in vertical or horizontal position. The adjustment device can be located over, below or in a horizontal...
Open the catalog to page 3123 Pages
21 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
18 Pages
6 Pages
35 Pages
11 Pages
2 Pages
15 Pages
14 Pages
2 Pages
145 Pages
15 Pages
12 Pages
7 Pages
6 Pages
9 Pages
20 Pages
22 Pages
20 Pages
19 Pages
19 Pages
19 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
8 Pages
31 Pages
12 Pages
19 Pages
10 Pages
18 Pages
25 Pages
26 Pages
31 Pages
19 Pages