Catalog excerpts
series KD Dual duct terminal units
Open the catalog to page 1Selection tables and Coding 6
Open the catalog to page 2Dual duct box, type KD Description The Koolair dual duct box, KD is utilised in systems where the accurate regulation of the air temperature is made by the actuation of a single spindle controlling both the heated and cooled air supplied into the mixing box. The box can be fitted with a constant flow regulator. The dual duct box has two spigot inlet connections for introduction of cold and hot air, spigots are circular or oval, depending on the size of the unit. Inlet duct dampers are interconnected and mounted at 90 degrees, with the control being carried out either electrically or...
Open the catalog to page 3Selection table. Description Regenerated noise (air flow). Sound pressure level in dB (A) for different static pressures of air intake ducts considering attenuation and local characteristic of -10 dB. Ps min: minimum static pressure (air inlet) Sample selection: Input data: Total airflow required out of KD dual duct box of 1300 m3 / h, operating with a maximum static pressure difference of 250 Pa. Sound pressure permissible at the site of 40 dB (A) with an attenuation characteristic in the area and ductwork system of -10 dB (A). Result: Model KD-RCQK-1000, with a regenerated noise level of...
Open the catalog to page 5THIS CATALOGUE IS INTELLECTUAL PROPERTY. Reproduction, either partial or total, by any means, including electronic, is prohibited without prior written authorisation from KOOLAIR, S.A. CIN-KD-0712-00
Open the catalog to page 6KOOLAIR, S.A. Calle Urano, 26 Poligono industrial nº 2 – La Fuensanta 28936 Móstoles - Madrid - (España) Tel: +34 91 645 00 33 Fax: +34 91 645 69 62 e-mail comercial: comercial@koolair.com e-mail Koolair: info@koolair.com
Open the catalog to page 7All KOOLAIR S.A catalogs and technical brochures
-
series FLOOR
23 Pages
-
series Dampers 100-2
21 Pages
-
FIRE protection
2 Pages
-
KOOLCOM
2 Pages
-
DFRE-P
1 Pages
-
PE-45
1 Pages
-
Acoustic
2 Pages
-
Series 100-200 Dampers
18 Pages
-
VENTILATION HOODS
6 Pages
-
Series SF Fire dampers
35 Pages
-
Series SCDC Smoke dampers
11 Pages
-
36-STE
2 Pages
-
DTP-GT Multi-nozzles diffusers
15 Pages
-
DTP Multi-nozzles diffusers
14 Pages
-
Koolair product range
2 Pages
-
Technical Selection Guide
145 Pages
-
Bypass terminal units – KMSR
15 Pages
-
Terminal units with fan – HVFS
12 Pages
-
Measurement Station – EM
6 Pages
-
Passive chilled beams – VPK
9 Pages
-
Induction terminal units – IHK
20 Pages
-
Square diffusers – Series 50
22 Pages
-
Multinozzles diffusers – DF49MT3
20 Pages
-
Long-throw nozzles – DF 89
19 Pages
-
Long-throw nozzles – DF 49
19 Pages
-
Linear grilles – Series 30
19 Pages
-
S26
1 Pages
-
21-DVC/21-DVR
1 Pages
-
21-SVC/21-SVR
1 Pages
-
20-SH/21-SH
1 Pages
-
20-DH/21-DH
1 Pages
-
Circular diffusers – DCL
2 Pages
-
Extract valves – Series GPD
8 Pages
-
Circular diffusers – Series 40.1
31 Pages
-
Security grilles – KSG
12 Pages
-
Return grilles – Series 20.2
19 Pages
-
Supply grilles – Series 26
10 Pages
-
Regulating dampers
18 Pages
-
Silencers – Series SK
25 Pages
-
Linear Diffusers – Series 70.1
26 Pages
-
Circular diffuser – Series 40.1
31 Pages
-
Supply grilles – Series 20.1
19 Pages