Active chilled beams – Series VFK 600

Active chilled beams – Series VFK 600
1 / 42 PagesView full catalog

Active chilled beams – Series VFK 600

Product catalog summary
General Characteristics
The VFK 600 is a ceiling-mounted induction terminal unit, also known as an active chilled beam, designed for air-water systems to enhance comfort in environments with high thermal loads. It includes a primary air plenum, hot or chilled water coil, linear slot diffusers, and a hinged perforated front face for easy cleaning. The system uses water for cooling or heating, offering energy and space savings compared to all-air systems. Room temperature control is possible with 2- or 3-way valves.
Advantages
The VFK 600 offers high energy efficiency, low maintenance costs, low noise levels, and a space-saving design, making it suitable for office buildings, hospitals, and hotels.
Dimensions and Configurations
Available in sizes from 600 to 3000 mm, the VFK 600 features different configurations based on the primary air connection position. Constructed from galvanized steel with a powder-paint finish, the coil is made of copper pipes and aluminum fins. Eurovent certification ensures quality and performance.
Installation
Designed for easy installation in various ceiling types, including lay-in grid, continuous, and tegular ceilings. Hanging brackets and hinged latches facilitate mounting and maintenance.
Nozzle Control Mechanism
An optional nozzle regulation mechanism allows for flexible air discharge configurations, enhancing adaptability to different installation requirements.
Air Deflectors
Optional air deflector slats can adjust the air jet direction, providing flexibility to handle obstacles and ensure an environment free of air currents.
Volume Regulation and Control Components
Includes components for both constant and variable water flow rate systems, such as room controllers, temperature sensors, and valves. Mechanical self-regulators ensure proper air control and balancing.
Specifications
The VFK 600 system operates on a 2-pipe or 4-pipe cooling system, with parameters for primary air flow, sound power level, primary air pressure drop, and water flow rate.
Technical Data
Includes selection tables for different nozzle types and their performance metrics such as air flow rate, sound levels, pressure drops, and cooling capacities.
Performance Metrics
Key indicators include primary air capacity, coil capacity, total capacity, and the throw of the air jet. Correction factors for different water flow rates adjust unit capacity accordingly.
Recommendations
For systems with variable air flow based on occupancy, a minimum inlet pressure of approximately 40 Pa is recommended. Manual balancing is required when using dampers.
Conclusion
The VFK 600 chilled beam system offers flexibility in cooling applications with detailed specifications and performance data to guide selection and installation. Proper configuration and balancing are crucial for achieving desired cooling efficiency.
Customization and Features
The VFK 600 series can be customized with additional services such as lighting, public-address systems, smoke detectors, and sprinklers. Customization at the project's inception is important to meet specific installation needs.
Example Configuration
An example of a VFK 600-MS active chilled beam includes integrated elements like LEDs, a sprinkler, and a speaker.
See more

Catalog excerpts

Active chilled beams – Series VFK 600-1

VFK 600 Active chilled beams

 Open the catalog to page 1
Active chilled beams – Series VFK 600-2

CONTENTS General CharacteristicsVFK 2 Selection in a sample project 33

 Open the catalog to page 2
Active chilled beams – Series VFK 600-3

General Features Description The VFK ceiling-mounted induction terminal units (also known as active chilled beams) for air diffusion are used in air-water systems to provide a high level of comfort in interior environments with high internal thermal loads in cooling operation. The units include the following components: Active Chilled Beam, lateral primary air connection - Primary air plenum, with one or two round duct connections for primary air inlet and a distribution of small nozzles with alternative settings. - Hot or chilled water (two-pipe installation) or hot and chilled water (four-pipe...

 Open the catalog to page 3
Active chilled beams – Series VFK 600-4

General Features Advantages The VFK are terminal units for central air conditioning ins- tallations that provide solutions to meet the needs of the following: - Ventilation achieved with primary air - Cooling, based on the primary air itself and the water circulation coil Heating, based on a water circulation coil - Control. Possibility of individual or combined unit control by room or area, using control and regulation valves in the unit to adjust the water volume and room thermostats. - Air diffusion based on linear slot diffusers that ensure effetive air diffusion. VFK 600 DV O In addition...

 Open the catalog to page 4
Active chilled beams – Series VFK 600-5

General Features VFK 600 Description The VFK 600 ceiling-mounted induction terminal units (also known as active chilled beams) for two-way air diffusion are used in airwater systems to provide a high level of comfort in interior environments with high internal thermal loads in cooling operation. The units include the following components: Active Chilled Beam, lateral primary air connection - Hinged perforated front face, used as access for unit cleaning. Available in different perforation designs. - Nozzle control mechanism, to configure different air discharge patterns in the nozzles. - Integrated...

 Open the catalog to page 5
Active chilled beams – Series VFK 600-6

Sizes 600 to 1800 - 2-pipe system (for 4-pipe system connections, refer to page 7) Five types of configurations are available, defined according to the position of the primary air connection with regard to the water connections (with the water connection viewed from the front), namely: 1. Front face primary air connection, on opposite side to water connections, (-F) type 2. Rear face primary air connection, on same side as water connections, (-FT) type 3. Lateral primary air connection on left side, (-LI) type 4. Lateral primary air connection on right side, (-LD) type 5. Primary...

 Open the catalog to page 6
Active chilled beams – Series VFK 600-7

Dimensions. Configurations VFK 600 Model Sizes 2100 to 3000 - 2-pipe system (for 4-pipe system connections, refer to page 7) Three types of configurations are available, defined according to the location of the primary air connection with regard to the water connections (with the water connection viewed from the front), namely: 3. Lateral primary air connections on left, (-LI) type 4. Lateral primary air connections on right, (-LD) type 5. Primary air connections at top, (-S) type Sizes 2100 to 3000 are manufactured with two LI or LD or S primary air connection inlets. Front air connection...

 Open the catalog to page 7
Active chilled beams – Series VFK 600-8

Dimensions. Configurations 4-PIPE SYSTEM.VFK 600 MODEL CHILLED FLOW & RETURN HOT FLOW & RETURN THREAD CONNECTION Same identification criteria for primary air connections as in a 2-pipe system, except that this system does not include the rear face configuration (-FT), i.e., on the same side as the water connections. PERFORATED INDUCTION RACK DESIGNS The following front induction rack designs are available for standard projects, when the order is placed: - P1H Rectangular perforations along the length of the beam. Rectangular perforations along the width of the beam. Round perforations distributed...

 Open the catalog to page 8
Active chilled beams – Series VFK 600-9

Installation - Chilled beam designs for different types of ceilings All VFK beam sizes are made to be installed in different kinds of false ceilings. The most common are listed below:: - Lay-in grid with T-support section with a width of 25 and 15 mm (1) - Continuous or plasterboard ceiling (2) - Tegular ceiling with drop face tile (3)

 Open the catalog to page 9
Active chilled beams – Series VFK 600-10

Installation - Fastening The VFK 600 units include a series of hanging brackets on the two upper longitudinal sides of the beams, as shown in the following photographs. There are two brackets per side in sizes 600 to 1800 and three in sizes 2100 to 3000. These brackets have a slot hole to hold a Ø6 mm threaded rod, which is first attached to the ceiling slab to hang the unit. Access rack The induction grille or front perforated rack can swing 90º by operating small latches on the side of the rack or by complete removal using the locks. This provides access to the interior of the chilled beam...

 Open the catalog to page 10
Active chilled beams – Series VFK 600-11

Nozzle Control Mechanism As an optional accessory, the unit can include a nozzle regulation mechanism (-SR). In this case, the chilled beams would be fitted with the two nozzle types or sizes, in which different air discharge configurations can be combined, making the installation highly flexible and able to adapt to various changes, situations or applications. The system allows the following nozzle configurations or types: - Position 1: Closure of all nozzles prevents the air from flowing out in one or two directions of the chilled beam. - Position 2: M-type large nozzle opening, to move medium...

 Open the catalog to page 11
Active chilled beams – Series VFK 600-12

Air deflectors As an optional accessory, the VFK 600 chilled beams can be fitted with air deflector slats (-DF) manufactured of M1 plastic, longitudinally built into the diffusers. By modifying the position, the air jet can be adjusted to different directions, making it a highly flexible unit to adapt to different situations in the installation. This makes it possible to handle obstacles, to broaden the width of the air jet and to slow the velocity of the jet over a specific throw, in short, to ensure an environment free of air currents. Several applications are shown below in the following figures:...

 Open the catalog to page 12
Active chilled beams – Series VFK 600-13

VFK 600 Volume Regulation and Control Components - Water According to the system used, type of control, electrical installation, etc., the usual control and regulation components per chilled beam or groups of units of the water system are the following: Constant water flow rate system Basic diagram of 4-pipe installation for constant water flow rate. 1. Active chilled beam 2. Room controller or regulator (on-site installation) Can be individual or integrated in a centralised regulation system. 3. Room temperature sensor (usually integrated 5. Electrical servo drive of the 3-way valve...

 Open the catalog to page 13

All KOOLAIR S.A catalogs and technical brochures

  1. series FLOOR

    23  Pages

  2. KOOLCOM

    2  Pages

  3. DFRE-P

    1  Page

  4. PE-45

    1  Page

  5. Acoustic

    2  Pages

  6. 36-STE

    2  Pages

  7. S26

    1  Page

  8. 20-SH/21-SH

    1  Page

  9. 20-DH/21-DH

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.