video corpo
cad

TrendVario 4300

TrendVario 4300
1 / 13 PagesView full catalog

TrendVario 4300

Product catalog summary
Overview: This document outlines the technical specifications, installation guidelines, and maintenance requirements for the TrendVario 4300 parking system, version 04.2019. It details dimensions, load capacities, and environmental conditions for optimal operation, as well as safety features and customization options.
Specifications:
  • Dimensions: The system offers various platform widths and heights, with a maximum recommended platform width of 270 cm for edge parking boxes and those with intermediate walls.
  • Load Capacity: Platforms support loads of 2000 kg and 2600 kg, with forces specified in kN and lbs.
  • Environmental Conditions: Operates in temperatures from -10 to +40°C and a relative humidity of 50% at maximum temperature.
Procedures:
  • Inspection and Maintenance: Annual expert inspections are required for gates with electric drives, following ASR A1.7. A maintenance agreement is recommended.
  • Installation: Requires dowelling to concrete floors and walls, with specific drilling depths. Electrical supply and grounding must comply with DIN EN 60204 standards.
Standards and Compliance:
  • Complies with DIN EN 14010 and EC Machine Directive 2006/42/EC, with TÜV SÜD voluntary conformity testing.
  • Sound insulation requirements per DIN 4109-1, with options for enhanced insulation under VDI 4100.
Recommendations:
  • Wider driveways are recommended for larger vehicles like SUVs, especially for side boxes.
  • Ensure proper ventilation and adhere to cleaning instructions to prevent corrosion.
Additional Information:
  • Building application documents are necessary for approval under LBO and GaVo regulations.
  • Customers must provide suitable electrical supply, drainage systems, and any required wall cuttings or door shields.
Electrical Requirements: Grounding of the steel structure is essential, with customer-provided electrical supply to the control box. The control system includes a hydraulic power unit, motor, and safety devices.
Safety Features: Safety is ensured through locked doors, chain monitoring systems, and locking levers. Platforms move only when doors are locked, with position sensing managed by electric signalers.
Door Specifications: Includes sliding and roller doors, with manual or electric operation options. Door panels come in various materials and colors, with features like ventilation and safety glass.
Installation and Operation: Requires a clear approach lane, with installation using seriated supports and steel pillars. The hydraulic unit and drive systems are designed for low noise and efficiency.
Customization and Updates: KLAUS Multiparking may update specifications and use newer technologies, ensuring no disadvantage to the customer.
See more

Catalog excerpts

TrendVario 4300-1

Page 3 Sliding door width dimensions Free space Detail free space see page 2 Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 7 Approach Free spaces Function Water drainage Clearance profile Height dimensions See page 2 for all pit and height dimensions. Page 10 Technical data Smallest type Standard type Special system: maximum load for extra charge. To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. Car width for platform width 230 cm [7’-7’’]. If wider platforms are used it is also possible to park wider cars. Potential equalization from foundation grounding connection to system (provided by the customer). Slope with drainage channel and sump. These floor areas need to be horizontal and on equal level across the full width of the pit Biggest type For convenient use of your parking space and due to the fact that the cars keep becoming longer we recommend a pit length of 570 cm [18’-8’’]. At the transition section between pit floor and walls no hollow mouldings/coves are possible. If hollow mouldings/coves are required, the systems must be designed smaller or the pits accordingly wider. If sprinklers are required make sure to provide the necessary free spaces during the planning stage. TrendVario 4300 | Code number 585.29.210-015 | Version 04.2019 Page 9 Load plan Standard passenger cars: Limousine, Station Sagon, SUV, Van according to clearance and maximum surface load. Page 8 Load plan Dimensions: cm [ft] Weights: kg [lbs] Forces: kN [lbf] Temperature: °C [°F] Page 6 Roll door width dimensions LF (lower floor) Grounding 5 Single parking spaces can Loadable up to also be upgraded to handle 2600 kg [5730 lbs] heavier loads at a later date! Tolerances for space requirements + 3 [+ 1’’ ] 0 0 Page 2 Height dimensions

 Open the catalog to page 1
TrendVario 4300-2

Page 2 Height dimensions Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Approach Free spaces Function Height dimensions TrendVario 4300 | Code number 585.29.210-015 | Version 04.2019 To be performed by the customer Page 12 Page 10 Technical data Page 9 Load plan Page 8 Load plan

 Open the catalog to page 2
TrendVario 4300-3

TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Sliding door behind columns Page 1 Section Car data Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Approach Free spaces Function Page 8 Load plan Page 9 Load plan Columns per each grid unit Usable platform width Carriageway in t accordance with local regulations No. of grids x RB + 20 [8“] ■ ©According to the ASR A1.7, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning, and...

 Open the catalog to page 3
TrendVario 4300-4

TrendVario 4300 | Code number 585.29.210-015 | Version 04.2019 Garages with sliding doors (standard) | Widths dimensions Sliding door between columns Page 2 Height dimensions Page 4 Sliding door width dimensions Page 8 Load plan Columns per each grid unit Not available! Columns every second grid unit Page 10 Technical data Carriageway in accordance with local regulations According to the ASR A1.7, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning, and then once a year, the gate has to be inspected by an expert and the findings entered in...

 Open the catalog to page 4
TrendVario 4300-5

TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Garages with sliding doors (standard) I Widths dimensions Sliding door in front of columns Page 1 Section Car data Free space Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Approach Free spaces Function Page 8 Load plan Page 9 Load plan Columns per each grid unit Carriageway in accordance with local regulations Usable platform width Columns every second grid unit Usable platform width Page 11 Electrical To be performed by the customer...

 Open the catalog to page 5
TrendVario 4300-6

TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Page 1 Section Car data Garages with roll doors I Widths dimensions Roll door behind columns Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Approach Free spaces Function Page 8 Load plan Columns per each grid unit Usable platform width Page 9 Load plan Carriageway in accordance with local regulations Page 11 Electrical To be performed by the customer ©According to the ASR A1.7, an inspection book is required for the commercial...

 Open the catalog to page 6
TrendVario 4300-7

TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Page 1 Section Car data Approach Page 2 Height dimensions Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions OThe illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility. Page 5 Sliding door width dimensions Longitudinal free space Page 6 Roll door width dimensions Page 7 Approach Free spaces Function Page 8 Load plan 14 RB = Grid unit...

 Open the catalog to page 7
TrendVario 4300-8

TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Page 8 of 13 TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Page 8 of 13 Page 1 Section Car data Load plan Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Approach Free spaces Function Page 8 Load plan Page 9 Load plan Page 11 Electrical To be performed by the customer

 Open the catalog to page 8
TrendVario 4300-9

TrendVario 4300 I Code number 585.29.210-015 I Version 04.2019 Load plan - top view Page 1 Section Car data Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Usable platform width _ RB I5 _ RBI _,RB2_ Page 7 Approach Free spaces Function Page 8 Load plan Page 9 Load plan OThe system is dowelled to floor and walls. The drilling depth in the floor is approx. 15 cm [6'']. The drilling depth in the walls is approx. 12 cm [5'']. Floor and walls are to be made of concrete (grade of concrete min. C20/25)! The...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.