This document provides comprehensive technical specifications, installation guidelines, operational procedures, and compliance requirements for the TrendVario 4000 automated parking system by KLAUS Multiparking GmbH. It is intended for planners, installers, and operators to ensure safe, functional, and durable system deployment.

1. Vehicle and Load Specifications

  • Vehicle Dimensions: Recommended pit lengths are 560 cm for vehicles up to 5.00 m and 580 cm for vehicles up to 5.20 m. Maximum vehicle width is 190 cm.
  • Weight Limits: Standard passenger cars up to 2000 kg with wheel loads up to 500 kg; special systems support up to 2600 kg and wheel loads up to 650 kg.

2. Dimensional Tolerances and Standards

  • All dimensions follow German Industrial Standards DIN 18202 (floor evenness) and VOB part C (DIN 18330/18331).
  • Platform widths typically 230 cm, with recommendations up to 270 cm for edge parking boxes to accommodate larger vehicles.
  • Strict adherence to grid unit widths (RB) between 230 cm and 290 cm is critical for system functionality.

3. Door Systems and Width Dimensions

  • Sliding doors are standard; configurations include doors behind, between, or in front of columns.
  • Door widths vary with grid unit widths; electrically driven doors require minimum 35 cm free space.
  • Electrically driven gates must undergo expert inspections per ASR A1.7 before commissioning and annually thereafter, with documented records.

4. Structural and Free Space Requirements

  • Minimum clearances specified for upper and ground floors, including around doors and platforms.
  • Customer must provide grounding and potential equalization for safety compliance.
  • Sprinkler system planning must consider required free spaces.

5. Load Plans and Platform Configurations

  • Load capacities can be upgraded for heavier vehicles.
  • Wider platforms (up to 270 cm) recommended for edge parking boxes and those with intermediate walls to prevent operational issues.
  • Wider driveways needed for larger vehicles, especially in side boxes due to limited maneuvering radius.

6. Height Dimensions

  • Vehicle heights range from 150 cm to 215 cm, with platform heights adjusted accordingly for both upper and ground floors.

7. Grid Arrangement and Carriageway

  • Grid unit widths (RB) must be strictly followed for proper door and platform operation.
  • Carriageway widths comply with local regulations, ranging from 230 cm to 290 cm.

8. Regulatory and Safety Recommendations

  • Compliance with DIN standards and ASR A1.7 for gate inspections is mandatory.
  • Inspection books for electrically driven gates must be maintained independently of maintenance schedules.
  • Customers are responsible for electrical installations, grounding, and safety fencing per DIN EN ISO 13857.

9. System Description and Mechanical Components

  • The TrendVario 4000 is a multi-level automated parking system with horizontally moving ground floor platforms and vertically moving upper floor platforms.
  • Steel framework includes supports, pillars, rails, and platform bases; platforms are suspended on four points with plastic sliding bearings.
  • Drive systems use gear motors, chain drives, and limit switches; lifting devices employ low-noise rollers and chains.

10. Door Systems Details

  • Sliding doors approx. 2500 mm wide and 2000 mm high, with frames made from anodized aluminum profiles.
  • Door panels available in various materials including perforated steel/aluminum, beaded steel plates, wood, laminated safety glass, and wire grating.
  • Doors run on adjustable twin-pair rolling gadgets; standard actuation is manual with optional electric motor drive.
  • Door panels and suspensions are optional extras, not included in the standard package.

11. Electrical Data and Installation Requirements

  • Control box dimensions approx. 100 x 100 x 30 cm, must be externally accessible.
  • Electrical supply varies by system size: up to 2 rows require 5 x 2.5 mm² cable with 3 x 20 A fuse; 3 rows require 5 x 4 mm² cable with 3 x 25 A fuse.
  • Grounding of steel structure mandatory per DIN EN 60204, with grounding points max 10 m apart.
  • Customer responsible for electrical supply, grounding, and wall cuttings for wiring.
  • On-site functionality monitoring requires coordination between fitters and electricians; customer must arrange electrician if needed.

12. Flooring and Rails

  • Concrete floors and walls must meet minimum grade C20/25 and evenness tolerances per DIN 18202.
  • Rail systems embedded fully in cement floor; no expansion joints allowed within rail area.
  • Floor pavement installation is required.

13. Safety and Control Features

  • Platforms move only behind locked doors for user safety.
  • Safety devices include chain monitoring, locking levers for upper platforms, and electric position sensors for door status.
  • Central control panel enables parking space selection.
  • Doors are manually operated by default; motorized doors available optionally.

14. Environmental and Sound Insulation Requirements

  • System designed for ambient temperatures between -10°C and +40°C, relative humidity up to 50%.
  • Sound insulation complies with DIN 4109-1 and VDI 4100, requiring sound protection packages and minimum building sound insulation (R’w = 57 dB or 62 dB for enhanced insulation).
  • User-generated noise is excluded from sound insulation requirements.

15. Compliance and Certification

  • System complies with DIN EN 14010 and EC Machine Directive 2006/42/EC.
  • Voluntary conformity testing by TÜV SÜD completed.
  • Documentation includes wall recess plans, maintenance offers, declarations of conformity, and sound test sheets.

16. Critical Notes and Customer Responsibilities

  • Strict adherence to specified dimensions, especially grid unit widths and platform widths, is essential.
  • Floor and wall construction must meet concrete grade and evenness tolerances.
  • Annual inspections and maintenance contracts for electrically driven doors are mandatory for commercial use.
  • Customer must provide electrical supply, grounding, safety fencing, building services, and obtain necessary approvals.
  • Additional costs for final technical approvals and optional components are borne by the customer.

17. Manufacturer Contact Information

KLAUS Multiparking GmbH
Hermann-Krum-Straße 2, D-88319 Aitrach
Phone: +49 (0) 7565 508-0
Fax: +49 (0) 7565 508-88
Email: [email protected]
Website: www.multiparking.com

Summary

The TrendVario 4000 automated parking system requires precise adherence to dimensional, load, electrical, and safety specifications to ensure reliable operation and compliance with German and European standards. The document serves as a detailed technical guide covering mechanical design, electrical installation, door systems, safety protocols, environmental conditions, and maintenance requirements. Customer responsibilities include providing electrical infrastructure, grounding, safety fencing, and coordinating inspections. Optional equipment and additional services are available at extra cost. Strict compliance with these guidelines is critical for system safety, functionality, and longevity.

See more

Catalog excerpts

TrendVario 4000-1

PRODUCT DATA Free space Detail free space see page 3 to 6 Page 5 Sliding door width dimensions Tolerances for space 3 requirements + 0 [+ 1’’ ] 0 Dimensions: cm [ft] Weights: kg [lbs] Forces: kN [lbf] Temperature: °C [°F] Standard passenger cars: Limousine, Station Sagon, SUV, Van according to clearance and maximum surface load. Standard 190 cm [6‘-3‘‘] Rail system see page 9 Clearance profile Page 7 Grid arrang. Approach Free spaces Function Page 6 Roll door width dimensions Page 8 Load plan Single parking spaces can Loadable up to also be upgraded to handle 2600 kg [5730 lbs] heavier loads at a later date! Page 4 Sliding door width dimensions Detail doors see page 3 to 6 Page 3 Sliding door width dimensions Page 2 Height dimensions Height dimensions See page 2 for all pit and height dimensions. Standard type Special system: maximum load for extra charge. To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. Car width for platform width 230 cm [7’-7’’]. If wider platforms are used it is also possible to park wider cars. Potential equalization from foundation grounding connection to system (provided by the customer). Tolerances for the evenness of the carriageway (floor) must be strictly complied with in accordance with DIN (=German Industrial Standard) No. 18202, chart 3, line 3. For convenient use of your parking space and due to the fact that the cars keep becoming longer we recommend a pit length of 580 cm [19’-0’’]. If sprinklers are required mak

 Open the catalog to page 1
TrendVario 4000-2

TrendVario 4000 I Code number 585.84.710-012 I Version 04.2019 Page 1 Section Car data Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Car height Car height Height UF GF Car height Car height Height UF GF Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Grid arrang. Approach Free spaces Function Page 8 Load plan Car height Car height Height UF GF Car height Car height Height UF GF Page 11 Electrical To be performed by the customer Car height Car height Height UF GF Ca r height Ca r height Height UF GF...

 Open the catalog to page 2
TrendVario 4000-3

TrendVario 4000 | Code number 585.84.710-012 | Version 04.2019 Garages with sliding doors (standard) | Widths dimensions Sliding door behind columns Page 2 Height dimensions Columns per each grid unit Page 8 Load plan Columns every second grid unit Carriageway in accordance with local regulations Carriageway in accordance with local regulations Page 10 Technical data Page 7 Grid arrang. Approach Free spaces Function Page 4 Sliding door width dimensions Page 6 Roll door width dimensions Free space Page 3 Sliding door width dimensions Page 5 Sliding door width dimensions According to the ASR A1.7...

 Open the catalog to page 3
TrendVario 4000-4

TrendVario 4000 | Code number 585.84.710-012 | Version 04.2019 Garages with sliding doors (standard) | Widths dimensions Sliding door between columns Page 2 Height dimensions Page 4 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Grid arrang. Approach Free spaces Function Columns every second grid unit Carriageway in accordance with local regulations According to the ASR A1.7 , an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning, and then once a year, the gate has to be inspected by an expert and the findings entered...

 Open the catalog to page 4
TrendVario 4000-5

TrendVario 4000 | Code number 585.84.710-012 | Version 04.2019 Sliding door in front of columns Free space Type 4000 Page 2 Height dimensions Page 4 Sliding door width dimensions Columns per each grid unit Page 7 Grid arrang. Approach Free spaces Function Carriageway in accordance with local regulations Page 8 Load plan Columns every second grid unit Page 10 Technical data Page 6 Roll door width dimensions Page 3 Sliding door width dimensions Page 5 Sliding door width dimensions Garages with sliding doors (standard) | Widths dimensions Carriageway in accordance with local regulations According...

 Open the catalog to page 5
TrendVario 4000-6

Garages with roll doors | Widths dimensions Roll door behind columns Page 3 Sliding door width dimensions Carriageway in accordance with local regulations According to the ASR A1.7 , an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning, and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has to be carried out independent of any maintenance work. Page 10 Technical data Columns per each grid unit Page 8 Load plan Page 7 Grid arrang. Approach Free spaces Function Page...

 Open the catalog to page 6
TrendVario 4000-7

TrendVario 4000 I Code number 585.84.710-012 I Version 04.2019 Page 1 Section Car data Grid arrangement For 2 rows max. 6 grids Page 3 Sliding door width dimensions Operating device ±===u Page 4 Sliding door width dimensions Approach Page 5 Sliding door width dimensions Page 6 Roll door width dimensions Page 7 Grid arrang. Approach Free spaces Function OThe illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility. Page...

 Open the catalog to page 7
TrendVario 4000-8

Page 2 Height dimensions Page 3 Sliding door width dimensions Page 4 Sliding door width dimensions Page 5 Sliding door width dimensions Load plan TrendVario 4000 | Code number 585.84.710-012 | Version 04.2019 Load plan – top view F2 Page 6 Roll door width dimensions Page 7 Grid arrang. Approach Free spaces Function Page 8 Load plan Page 10 Technical data Page 11 To be performed by the customer Page 12 Platform load in kg Platform load 2000 kg 2600 kg Platform load in lbs Platform load 4400 lbs 5730 lbs The system is dowelled to floor and walls. The drilling depth in the floor is approx. 15 cm [6’’]....

 Open the catalog to page 8
TrendVario 4000-9

Rail load by moving traffic load: – For surface load 2000 kg [4400 lbs]: 6,5 kN [1,461lbf] per wheel – For surface load 2600 kg [5730 lbs]: 8 kN [1,798 lbf] per wheel Laying on finished floor Direction of parking Guide rail 1,5 [0,6‘‘] Top edge of finished floor Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 18202, chart 3, line 3. No expansion joints are permitted within the area of the rail system. 1 We do not recommend mastic asphalt. Evenness and Tolerances (abstract from DIN 18 202, table 3) The distance...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.