Catalog excerpts
PRODUCT DATA Outdoor installation All space requirements are minimum finished dimensions. Tolerances for space 3 1’’ requirements + 0 [+ 0 ] EB (single platform) = 2 vehicles Dimensions: cm [ft] Weights: kg [lbs] Forces: kN [lbf] Temperature: °C [°F] Function Width dimensions Approach Load per parking space Load plan Electrical installation 520 [17‘-1‘‘] for vehicle up to 5.00 m [16‘-5‘‘] long (540 [17‘-9‘‘] for vehicle up to 5.20 m [17‘-1‘‘] long) Technical data Standard passenger cars: Limousine, Station Wagon, SUV, Van according to clearance and maximum surface load. Standard Special 1 190 cm [6‘-3‘‘] 3 190 cm [6‘-3‘‘] 3 see page 4 wheel load see page 4 Clearance profile Height dimensions Smallest type Special system: maximum load for extra charge. To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. Car width for platform width 230 cm [7’-7’’]. If wider platforms are used it is also possible to park wider cars. Potential equalization from foundation grounding connection to system (provided by the customer). Biggest type Three-sided barrier compliant to DIN EN ISO 13857. Depending on location, design also as wind protection. In compliance with DIN EN 14010, 10 cm [4’’] wide yellow-black markings compliant to ISO 3864 must be applied by the customer to the edge of the platform in the access area to mark the danger zone in front of the supporting surface of the upper platform edge (see „Load Plan“ Page 4). For convenient use of your parking space and due to the fact that the cars keep becoming longer we recommend a length of 540 cm [17’-9’’]. SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 See page 2 for all height dimensions. width weight Before lowering
Open the catalog to page 1SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Height dimensions Function Width dim. Approach Load per parking space Load plan Electrical installation Page 2 Height dimensions Car height lower level 160 [5‘-3‘‘] Car height lower level 150 [4‘-11‘‘] To be performed by the customer Description Car height lower level 180 [5‘-11‘‘] Car height lower level 170 [5‘-7‘‘] Technical data Car height lower level 190 [6‘-3‘‘] Car height lower level 200 [6‘-7‘‘] To the extent that the conditions of the construction
Open the catalog to page 2SingleVario 2061 Outdoor installation I Code number 586.50.190-005 I Version 09.2018 System lifted System lowered Page 1 Section Car data Page 4 Load per parking space Load plan Page 5 Electrical installation Page 7 To be performed by the customer Description Width dimensions Single Platform (EB) Usable platform width OFor parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm [8'-10'']. Problems may occur if smaller platform widths are used (depending on car type, access and individual driving behaviour and capability). For larger...
Open the catalog to page 3SingleVario 2061 Outdoor installation I Code number 586.50.190-005 I Version 09.2018 Page 1 Section Car data Load per parking space For countries where snow loads are a crucial factor (weights in kg) For countries where snow loads is no relevant factor (weights in kg) Page 4 Load per parking space Load plan SingleVario 2061 2,0 to. (only EB) parking spaces weight wheel load , upper parking space 1500 kg 375 kg SingleVario 2061 2,6 to. (only EB) - for extra charge parking spaces weight wheel load , upper parking space 2000 kg 500 kg For countries where snow loads are...
Open the catalog to page 4SingleVario 2061 Outdoor installation I Code number 586.50.190-005 I Version 09.2018 Page 1 Section Car data Electrical installation Installation diagram Electrical data (to be performed by the customer) Page 2 Height dimensions Page 4 Load per parking space Load plan Page 5 Electrical installation No. Qunatity Description Position Frequency 1 1 Electricity meter in the supply 3 x fuse 16 A (slow) or circuit breaker 3 x 16 A (tri gger characteristic K or C) 2 x fuse 32 A (slow) or circuit breaker 2 x 32 A (tri gger characteristic K or C) 3 x fuse 25 A (slow) or circuit breaker 3...
Open the catalog to page 5Page 2 Height dimensions Page 3 Function Width dimensions Approach Load per parking space Load plan Electrical installation Technical data To be performed by the customer Description SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 Technical data By default, the system can only be used for a fixed number of users. If different users use the system – only on the upper parking spaces – (e.g. short-time parkers in office buildings or hotels) the Multiparking system needs to be adjusted. If required, would you please contact us. Units Low-noise power units...
Open the catalog to page 6Page 2 Height dimensions Page 3 SingleVario 2061 Outdoor installation | Code number 586.50.190-005 | Version 09.2018 To be performed by the customer Safety fences Constraints according to DIN EN ISO 13857 must be put in place on three sides (all except the entrance side), unless buildings border the traffic ways around the system. Numbering of parking spaces Consecutive numbering of parking spaces. Building services Function Width dimensions Approach Any required lighting, ventilation, fire extinguishing and fire alarm systems as well as clarification and compliance with the relevant regulatory...
Open the catalog to page 7All KLAUS Multiparking GmbH catalogs and technical brochures
-
TrendVario 4300
13 Pages
-
TrendVario 4200
13 Pages
-
TrendVario 4100
13 Pages
-
TrendVario 4000
13 Pages
-
MultiBase 2072i
12 Pages
-
SingleVario 2061
12 Pages
-
MultiBase 2072i outdoor
8 Pages
-
MasterVario S
6 Pages
-
flyers
2 Pages
-
KLAUS Multiparking NEWS
8 Pages
-
HILINE CORROSION PROTECTION
4 Pages
-
MultiBase U10
7 Pages
-
MultiBase U20
7 Pages
-
MultiBase U3
7 Pages
-
ParkBoard PQ
5 Pages
-
ParkBoard PE/PH
6 Pages
-
MultiBase 2078i
7 Pages
-
SingleUp 3015
5 Pages
-
SingleUp 2015
4 Pages
-
MultiBase G63
6 Pages
-
MultiBase 2042
7 Pages
-
MultiBase G63 outdoor
5 Pages
-
MultiBase G82
7 Pages
-
Premium Parking Systems
20 Pages
-
Folder BikeSafe
3 Pages
-
Folder AluLongLife
2 Pages
-
Folder Underfloor
2 Pages
-
MasterVario R3 L
5 Pages
-
MasterVario LS
5 Pages
-
MasterVario R2 L
4 Pages
-
MasterVario R2 C
5 Pages
-
MasterVario F3
5 Pages
-
MasterVario F2
3 Pages
-
MasterVario R3 C
6 Pages
-
ParkDisc D450
4 Pages