SingleUp 2015
4Pages

{{requestButtons}}

Catalog excerpts

SingleUp 2015 - 1

Page 1 Section Dimensions Car data Page 2 Width dim. Function Approach Load plan Page 3 Electrical installation Technical data Page 4 To be performed by the customer Description All space requirements are minimum finished dimensions. Tolerances for space requirements+0 . 1 Dimensions in cm. EB (single platform) = 2 vehicles Suitable for Standard passenger cars: Limousine, station wagon, SUV, van according to clearance and maximal surface load. width 190 cm weight max. 2500 kg wheel load max. 625 kg Before lowering the platform, the vehicle parked on the lower parking space must be driven off! Version 1: above backward; below forward 2015-155 190! car height car height height above (L) 7 below (L+S) 305 150 150cqZIc^ <1 To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. <2 If a higher ceiling height is available higher cars can be parked. (3 If the total length is greater, the max. vehicle length for the lower parking space increases accordingly. (4 For dividing walls: cutting through 10 x 10 cm. <5 Potential equalization from foundation grounding connection to system (provided by the customer). <6 In compliance with DIN EN 14 010, 10 cm wide yellow-black markings compliant to ISO 3864 must be applied by the customer with a distance of 90 cm to the edge of the platform in the access area to mark the danger zone in front of the supporting surface of the upper platform edge (see „Load Plan' Page 2). <7 L = Limousine / S = Station wagon <8 Must be at least as high as the greatest car height + 5 cm. SingleUp 2015 I Code number 583.91.470-010 I Version 12.2016

Open the catalog to page 1
SingleUp 2015 - 2

SingleUp 2015 | Code number 583.91.470-010 | Version 12.2016 Width dimensions Technical data To be performed by the customer Description usable platform width 210 220 230 System lifted System lowered Before lowering the platform, the vehicle parked on the lower parking space must be driven off! maximum descending slope 4 % The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility. Load plan Electrical...

Open the catalog to page 2
SingleUp 2015 - 3

SingleUp 2015 I Code number 583.91.470-010 I Version 12.2016 Page 1 Section Dimensions Car data Electrical installation Electrical data (to be performed by the cu sto mer) Page 2 Width dim. Function Approach Load plan Page 4 To be performed by the customer Description No. Qunatity Description Position Frequency 1 1 E lectricity meter in the supply 2 1 Main fuse: 3 x fuse 16 A (slow) in the supply 1 per unit or circuit b reake r 3 x 16 A line (t rig ger cha racteristic K or C) 3 1 Supply line 5 x 2.5 mm2 to mai n switch 1 per unit (3 PH + N + PE)...

Open the catalog to page 3
SingleUp 2015 - 4

Page 2 Width dim. Function Approach Load plan Page 3 Electrical installation Technical data To be performed by the customer Description Safety fences Any constraints that may be necessary according to DIN EN ISO 13857 in order to provide protection, for pathways directly in front, next to or behind the unit. This is also valid during construction. Numbering of parking spaces Consecutive numbering of parking spaces. Operating device Cable conduits and recesses for operating device (for double wing doors: please contact the local agency of KLAUS Multiparking). Operating device exposed...

Open the catalog to page 4

All KLAUS Multiparking GmbH catalogs and technical brochures

  1. flyers

    2 Pages

  2. MultiBase U3

    7 Pages

  3. ParkBoard PQ

    5 Pages

Archived catalogs