Catalog excerpts
Page 1 Dimensions Car data Page 2 Examples Drive S Evenness tolerances Page 3 Example Drive U Rail system PRODUCT DATA parkboardPE parkboardPH longitudinally shifting 2000 kg 1 / 2300 kg 2 Page 5 Electrical installation Technical data Page 6 To be performed by the customer Description Top edge finished floor Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 18202, chart 3, line 3. Dimensions All space requirements are minimum finished dimensions. Tolerances for space requirements + 3. 3 Dimensions in cm. Type L B Travel path Travel path Suitable for Standard passenger cars: Limousine, station wagon, SUV, van, according to specifications in the table and maximal surface load. width length height weight wheel load Standard Special 2 max. 190 cm max. 190 cm max. 500 cm max. 500 cm 10 cm less than headroom max. 2000 kg max. 2300 kg max. 500 kg max. 575 kg ParkBoard PEParkBoard PH O Building law requirements According to the German Building Code parking spaces on longitudinally shifting parking pallets are only permitted if the following requirements are met: - Next to the ParkBoards a remaining driving lane width of 275 cm minimum must be maintained. - ParkBoards must not be installed before power-driven parking systems. - In case of two-way traffic in the driving lane no through traffic is permitted. - The ParkBoards must be traversable on all sides. - Walkable areas must provide headroom of 200 cm. Make sure to observe the ventilation systems, bearers or other installations. The ParkBoards have a height of 9,5 cm. Standard type 3 To follow the minimum finished dimensions, make sure 2 Special system: maximum load (PE-245/PH-245) to consider the tolerances according to VOB, part C for extra charge. (DIN 18330 and 18331) and the DIN 18202. ParkBoard PE/PH I Code number 584.16.990-007 I Version 10.2017
Open the catalog to page 1ParkBoard PE/PH I Code number 584.16.990-007 I Version 10.2017 Page 1 Dimensions Car data Page 2 Examples Drive S Evenness tolerances Page 3 Example Drive U Rail system At a length of 40 m up to 5 pallets can be arranged as group should their shifting path overlap. In this case the operating elements must be within a distance of 10 m of a possible point of contact between two pallets. <4 Recommendation of KLAUS Multiparking. Cover marked with yellow/black stripes MM Evenness and tolerances (abstract from DIN 18 202, table 3) The distance between the lower flange of the ParkBoards and the...
Open the catalog to page 2Evenness tolerances ParkBoard PE/PH | Code number 584.16.990-007 | Version 10.2017 Example: Longitudinal Pallets with Underfloor Drive (Drive U) If the drive axis cannot be placed in front of a support the drive will be designed as underfloor drive. Precondition: Drive axis located in parking space axis; recess in floor. For arrangement of longitudinal pallets, see example. 2 x ParkBoard PH Conduit EN 40 (M40) with taut wire to nearest support or to wall Rail system Underfloor Drive (Drive U) Parking space border Technical data Electrical installation To be performed by the customer Description...
Open the catalog to page 3ParkBoard PE/PH | Code number 584.16.990-007 | Version 10.2017 Parking space border Evenness tolerances Rail system Page 4 Incline Notes Electrical installation Technical data in this area the same level is necessary 260 (290) Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 18202, chart 3, line 3. No expansion joints are permitted within the area of the rail system. Accessing standard parking spaces (for example No. 6) 1 Operating element for ParkBoard 21 Operating element for ParkBoard 20 If ParkBoard...
Open the catalog to page 4Evenness tolerances Rail system Page 4 Incline Notes ParkBoard PE/PH | Code number 584.16.990-007 | Version 10.2017 Electrical installation Electrical supply / Control system The customer must provide a supply of 5 x 2,5 mm2 (3 PH +N+ PE) to the electric cabinet (larger systems may require larger cross sections). Proposals for position of control box and operating element are specified in the floor plans provided by KLAUS Multiparking. Technical data By default, the system can only be used for a fixed number of users. If different users use the system (e.g. short-time parkers in office...
Open the catalog to page 5Evenness tolerances Rail system Page 4 Incline Notes Electrical installation Technical data To be performed by the customer Description ParkBoard PE/PH | Code number 584.16.990-007 | Version 10.2017 To be performed by the customer Numbering of parking spaces Consecutive numbering of stationary parking spaces and longitudinal shifting ParkBoards. Building services Any required lighting, ventilation, fire extinguishing and fire alarm systems as well as clarification and compliance with the relevant regulatory requirements. Marking Any additional yellow-black markings on the platform edges...
Open the catalog to page 6All KLAUS Multiparking GmbH catalogs and technical brochures
-
TrendVario 4300
13 Pages
-
TrendVario 4200
13 Pages
-
TrendVario 4100
13 Pages
-
TrendVario 4000
13 Pages
-
MultiBase 2072i
12 Pages
-
SingleVario 2061
12 Pages
-
SingleVario 2061 outdoor
7 Pages
-
MultiBase 2072i outdoor
8 Pages
-
MasterVario S
6 Pages
-
flyers
2 Pages
-
KLAUS Multiparking NEWS
8 Pages
-
HILINE CORROSION PROTECTION
4 Pages
-
MultiBase U10
7 Pages
-
MultiBase U20
7 Pages
-
MultiBase U3
7 Pages
-
ParkBoard PQ
5 Pages
-
MultiBase 2078i
7 Pages
-
SingleUp 3015
5 Pages
-
SingleUp 2015
4 Pages
-
MultiBase G63
6 Pages
-
MultiBase 2042
7 Pages
-
MultiBase G63 outdoor
5 Pages
-
MultiBase G82
7 Pages
-
Premium Parking Systems
20 Pages
-
Folder BikeSafe
3 Pages
-
Folder AluLongLife
2 Pages
-
Folder Underfloor
2 Pages
-
MasterVario R3 L
5 Pages
-
MasterVario LS
5 Pages
-
MasterVario R2 L
4 Pages
-
MasterVario R2 C
5 Pages
-
MasterVario F3
5 Pages
-
MasterVario F2
3 Pages
-
MasterVario R3 C
6 Pages
-
ParkDisc D450
4 Pages