MultiBase U3
7Pages

{{requestButtons}}

Catalog excerpts

MultiBase U3 - 1

PRODUCT DATA Width dimensions Page 3 Approach Load plan Standard passenger cars: Limousine, station wagon, SUV, van according to clearance and maximal surface load. Electrical installation Technical data To be performed by the customer Page 7 Standard Special 2 190 cm 4 190 cm 4 max. 2000 kg max. 2600 kg wheel load max. 500 kg max. 650 kg width weight Clearance profile Water drainage 100 530 for vehicle up to 5.00 m = 16’4’’ long (550 for vehicle up to 5.20 m 17’ long) All space requirements are minimum finished dimensions. Tolerances for space requirements + 3 . 0 Dimensions in cm. EB (single platform) = 3 vehicles DB (double platform) = 6 vehicles Standard type Special system: maximum load for extra charge. To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. Car width for platform width 230 cm. If wider platforms are used it is also possible to park wider cars. Potential equalization from foundation grounding connection to system (provided by the customer). Slope with drainage channel and sump see page 3. In compliance with DIN EN 14010, 10 cm wide yellow-black markings compliant to ISO 3864 must be applied by the customer to the edge of the pit in the entry area to mark the danger zone (see „load plan“ page 4). At the transition section between pit floor and walls no hollow mouldings/coves are possible. If hollow mouldings/coves are required, the systems must be designed smaller or the pits accordingly wider. If necessary, protective gratings are installed at the back area The upper platform is a frame construction. Flooring can be provided by the customer (e.g. soil/turf, sandbed/turfblock, sandbed/marble, etc.). Maximum weight of customer coating 250 kg/m2 – please contact KLAUS Multiparking. The upper platform is at ground level and is traversible when in lowered position (vehicle load: 2600 kg maximum, wheel load: 650 kg maximum). A separate maintenance manhole must be installed by the customer (with manhole cover, ladder and a connecting passage to the pit). A save maintenance access with a door has to be provided by the customer – please contact KLAUS Multiparking. The hydraulic power unit and ventilation system are also housed in the maintenance manhole After operation, the system must always be run into the lowest final position (key interlock). MultiBase U3 | Code number 586.65.850-003 |

Open the catalog to page 1
MultiBase U3 - 2

MultiBase U3 I Code number 586.65.850-003 I Version 03.2018 Page 1 Section Dimensions Car data Page 3 Approach Load plan +-B B-17^-B-175-B-+ Page 6 Tec. data To be performed by the customer Shaft for maintenance Door (performed by the customer) Usable platform width Platform width parking levels top platform All sidewalls must be in a rectangular angel. Max. tolerances are 1 cm! Warning: If the side or backside is freely accessible these areas must be safeguarded (railing, marking etc.). Measures to be taken according to project. End parking spaces are generally more difficult to...

Open the catalog to page 2
MultiBase U3 - 3

MultiBase U3 | Code number 586.65.850-003 | Version 03.2018 Width dimensions Page 3 Approach Load plan maximum descending slope 3 % maximum ascending slope 10 % Electrical installation Technical data The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility. Load plan Upper platform with sheet metal plates usable platform width Upper platform with stone layer usable platform width usable platform width + 25 Units...

Open the catalog to page 3
MultiBase U3 - 4

MultiBase U3 | Code number 586.65.850-003 | Version 03.2018 Circular drainage channel Width dimensions Floor drain Page 3 Approach Load plan Electrical installation Base plate Technical data Base plate Base plate Base plate On-site coating of the uppermost platform Maximum weight of customer coating 250 kg/m2. Coating with asphalt or concrete Edge stripping Edge stripping Before filling the trough with concrete or asphalt, edge stripping must be placed around the edges on site. Before filling, the trough must be lined with a water-impermeable foil by a specialist company on site. Dimensions...

Open the catalog to page 4
MultiBase U3 - 5

MultiBase U3 I Code number 586.65.850-003 I Version 03.2018 Page 1 Section Dimensions Car data Electrical installation Electrical data (to be performed by the customer) Page 2 Width dimensions Page 3 Approach Load plan Page 6 Tec. data To be performed by the customer 1 Elect ricity meter 3 x fuse 32 A (slow) o r circuit breake r 3 x 32 A (tr ig ger characteristic K or C) 1 Sup p ly line 5 x 6 mm 2 (3 PH + N + PE) wit h ma rked wire and protect ive conductor 1 Separate supply line (230 V) with lig ht ing and power outlet every Foundation earth connector 10 m Equipotential bo nd ing...

Open the catalog to page 5
MultiBase U3 - 6

Width dimensions Page 3 Approach Load plan Page 4 Pit Electrical installation Technical data To be performed by the customer Page 7 MultiBase U3 | Code number 586.65.850-003 | Version 03.2018 Technical data Sound insulation According to DIN 4109 (Sound insulation in buildings), para. 4, annotation 4, KLAUS Multiparkers are part of the building services (garage systems). Normal sound insulation: DIN 4109, para. 4, Sound insulation against noises from building services. Table 4 in para. 4.1 contains the permissible sound level values emitted from building services for personal living and...

Open the catalog to page 6
MultiBase U3 - 7

Width dimensions Page 3 Approach Load plan Page 4 Pit Electrical installation Technical data To be performed by the customer Page 7 MultiBase U3 | Code number 586.65.850-003 | Version 03.2018 Description Single platform (EB) and Double platform (DB) General description: Multiparking system providing independent parking spaces for 3 cars (EB), 2 x 3 cars (DB) one on top of the other each. Dimensions are in accordance with the underlying dimensions of parking pit, height and width. The parking bays are accessed horinzotally (installation deviation ± 1 %). Vehicles are positioned on each...

Open the catalog to page 7