MultiBase G63
6Pages

{{requestButtons}}

Catalog excerpts

MultiBase G63 - 1

Page 1 Section Dimensions Car data Page 2 Width dim. without door PRODUCT DATA CONFORM rTY multibase G63 2000 kg 1 Page 3 Width dim. with door Function Approach Page 4 Load plan Installation All space requirements are minimum finished dimensions. Tolerances for space requirements+3. Dimensions in cm. EB (single platform) = 3 vehicles DB (double platform) = 6 vehicles Page 6 To be performed by the customer Description Standard passenger cars: Limousine, station wagon, SUV, van according to clearance and maximal surface load. weight max. 2000 kg max. 2500 kg wheel load max. 500 kg max. 625 kg Clearance profile <1 Standard type <2 Special system: maximum load (only EB) for extra charge. (3 To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. <4 Car width for platform width 230 cm. If wider platforms are used it is also possible to park wider cars. <5 If a higher ceiling height is available higher cars can be parked. <6 For dividing walls: cutting through 10 x 10 cm. <7 Potential equalization from foundation grounding connection to system (provided by the customer). <8 In compliance with DIN EN 14010, 10 cm wide yellow-black markings compliant to ISO 3864 must be applied by the customer to the edge of the pit in the entry area to mark the danger zone (see „load plan“ page 4). <9 Slope with drainage channel and sump. 10 At the transition section between pit floor and walls no hollow mouldings/coves are possible. If hollow mouldings/coves are required, the systems must be designed smaller or the pits accordingly wider. 11 For convenient use of your parking space and due to the fact that the cars keep becoming longer we recommend a pit length of 540 cm. 12 Must be at least as high as the greatest car height + 5 cm. MultiBase G63 I Code number 583.91.490-008 I Version 12.2016

Open the catalog to page 1
MultiBase G63 - 2

MultiBase G63 I Sach-Nummer 583.91.490-008 I Ausgabe 12.2016 Page 1 Section Dimensions Car data Width dimensions for garage without door (basement garage) Dividing walls Page 2 Width dim. without door Page 3 Width dim. with door Function Approach Page 4 Load plan Installation usable platform width 230 240 250 260 270 usable platform width 460 470 480 490 500 Single and Double Platform (EB + DB) - Example Single and Double Platform (EB + DB) - Example Page 6 To be performed by the customer Description usable platform width 230 240 250 260 270 Columns outside pit Singl e Platform (EB) usable...

Open the catalog to page 2
MultiBase G63 - 3

MultiBase G63 | Sach-Nummer 583.91.490-008 | Ausgabe 12.2016 Garage with door Free space for roller shutter Width dimensions for garage with door Width dim. without door Headroom according to door specifications Page 3 Width dim. with door Function Approach Load plan Electrical installation Technical data Dimensions A1, A2 and A3 must be coordinated with the door supplier (provided by the customer). Slope with drainage channel and sump. Seat-engaging surface (dimensions require coordination with door supplier.) Allround door dimensions require coordination between door supplier and local...

Open the catalog to page 3
MultiBase G63 - 4

MultiBase G63 | Sach-Nummer 583.91.490-008 | Ausgabe 12.2016 Load plan Width dim. without door Page 3 Width dim. with door Function Approach Load plan Electrical installation platform load Technical data Units are dowelled to the floor. Drilling depth: approx. 15 cm. Floor and walls below the drive-in level are to be made of concrete (quality minimum C20/25)! The dimensions for the points of support are rounded values. If the exact position is required, please contact KLAUS Multiparking. Marking compliant to ISO 3864 (colors used in this illustration are not ISO 3864 compliant) Installation...

Open the catalog to page 4
MultiBase G63 - 5

MultiBase G63 | Sach-Nummer 583.91.490-008 | Ausgabe 12.2016 Electrical installation Installation diagram Foundation earth connector Supply line 5 x 2.5 mm2 (3 PH + N + PE) with marked wire and protective conductor Equipotential bonding in accordance with DIN EN 60204 from foundation earth connector to the system Lockable main switch Supply line 5 x 2,5 mm2 (3 PH + N + PE) with marked wire and protective conductor Operating device Electrical data (included in delivery of KLAUS Multiparking) Technical data Load plan Main fuse: 3 x fuse 20 A (slow) or circuit breaker 3 x 20 A (trigger...

Open the catalog to page 5
MultiBase G63 - 6

Width dim. without door Page 3 Width dim. with door Function Approach Page 4 Load plan Electrical installation Technical data To be performed by the customer Description Safety fences Any constraints that may be necessary according to DIN EN ISO 13857 in order to provide protection for the park pits for pathways directly in front, next to or behind the unit. This is also valid during construction. Railings for the system are included in the series delivery when necessary. Numbering of parking spaces Consecutive numbering of parking spaces. Building services Any required lighting,...

Open the catalog to page 6