MultiBase 2078i - 1

Standard Special 3 190 cm 4 190 cm 4 max. 2000 kg max. 2600 kg wheel load max. 500 kg max. 650 kg width weight car height lower upper 150 (L) 190 (L+S) 150 (L+S) 190 (L+S) 190 (L) 190 (L+S) 190 (L+S) 190 (L+S) car height upper lower 150 (L) 200 (L+S) 150 (L+S) 200 (L+S) 200 (L) 200 (L+S) 200 (L+S) 200 (L+S) car height upper lower 150 (L) 205 (L+S) 150 (L+S) 205 (L+S) 205 (L) 205 (L+S) 205 (L+S) 205 (L+S) Standard type Special system: maximum load for extra charge (maximum load for EB up to 3000 kg per place for extra charge). To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. Car width for platform width 230 cm. If wider platforms are used it is also possible to park wider cars. If a higher ceiling height is available higher cars can be parked. For dividing walls: cutting through 10 x 10 cm. Potential equalization from foundation grounding connection to system (provided by the customer). 190 car height upper lower 150 (L) 170 (L+S) 150 (L+S) 170 (L+S) 170 (L) 170 (L+S) 170 (L+S) 170 (L+S) car height upper lower 150 (L) 180 (L+S) 150 (L+S) 180 (L+S) 180 (L) 180 (L+S) 180 (L+S) 180 (L+S) 185 car height upper lower 150 (L) 165 (L+S) 150 (L+S) 165 (L+S) 165 (L) 165 (L+S) 165 (L+S) 165 (L+S) car height upper lower 150 (L) 155 (L+S) 150 (L+S) 155 (L+S) 155 (L) 155 (L+S) 155 (L+S) 155 (L+S) car height height upper lower 290 150 (L) 150 (L+S) 305 150 (L+S) 150 (L+S) car height upper lower 150 (L) 215 (L+S) 150 (L+S) 215 (L+S) 215 (L) 215 (L+S) 215 (L+S) 215 (L+S) In compliance with DIN EN 14010, 10 cm wide yellow-black markings compliant to ISO 3864 must be applied by the customer to the edge of the pit in the entry area to mark the danger zone (see „load plan“ page 4). Slope with drainage channel and sump. At the transition section between pit floor and walls no hollow mouldings/coves are possible. If hollow mouldings/coves are required, the systems must be designed smaller or the pits accordingly wider. For convenient use of your parking space and due to the fact that the cars keep becoming longer we recommend a pit length of 550 cm. Must be at least as high as the greatest car height + 5 cm. MultiBase 2078i | Code number 587.41.450-003 | Version 07.2017 Clearance profile Station wagon (S) 530 for vehicle up to 5.00 m = 16ʼ4ʼʼ long (550 for vehicle up to 5.20 m 17ʼ long) 11 Technical data Water drainage Electrical installation Clearance profile Limousine (L) Load plan Standard passenger cars: Limousine, station wagon, SUV, van according to clearance and maximal surface load. All space requirements are minimum finished dimensions. 3 Tolerances for space requirements + 0 . Dimensions in cm. EB (single platform) = 2 vehicles DB (double platform) = 4 vehicles Free space Cutting through Page 3 Width dim. with door Function Free space Width dim. without door Headroom according 12 to local regulations Garage without door (basement garage) PRODUCT DATA

Open the catalog to page 1
MultiBase 2078i - 2

MultiBase 2078i I Code number 587.41.450-003 I Version 07.2017 Page 1 Section Dimensions Car data Width dimensions for garage without door (basement garage) Dividing walls Page 2 Width dim. without door Page 3 Width dim. with door Function Page 4 Approach Load plan usable platform width 230 240 250 260 270 usable platform width 460 470 480 490 500 510 520 530 540 Single and Double Platform (EB + DB) - Example Single and Double Platform (EB + DB) - Example usable platform width 460 470 480 490 500 510 520 530 540 Carriageway in accordance with usable platform width B4 B5 local...

Open the catalog to page 2
MultiBase 2078i - 3

Page 1 Section Dimensions Car data Page 2 Width dim. without door Page 3 Width dim. with door Function Page 4 Approach Load plan Page 7 To be performed by the customer Description Carriageway in accordance with local regulations door entrance width B6 13 Dimensions A1, A2 and A3 must be coordinated with the door supplier (provided by the customer). 14 Slope with drainage channel and sump. 15 Seat-engaging surface (dimensions require coordination with door supplier.) Allround door dimensions require coordination between door supplier and local agency of KLAUS Multiparking. Carriageway in...

Open the catalog to page 3
MultiBase 2078i - 4

MultiBase 2078i I Code number 587.41.450-003 I Version 07.2017 Page 1 Section Dimensions Car data Approach Page 2 Width dim. without door Page 3 Width dim. with door Function Page 4 Approach Load plan OThe illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking accepts no responsibility. Page 7 To be performed by the customer Description EB 2000 kg EB 2600 kg EB 3000 kg DB 2000 kg DB 2600 kg Units are dowelled to the floor. Drilling depth:...

Open the catalog to page 4
MultiBase 2078i - 5

Page 1 Section Dimensions Car data Page 2 Width dim. without door Page 3 Width dim. with door Function Page 4 Approach Load plan __- Free space for horizontal ducting Example for ventilation branch canal and/or vertical pipelines. Page 7 To be performed by the customer Description ^ Free space only applicable if vehicle is parked forwards = FRONT FIRST and driver's door on the left side. Electrical installation Installation diagram Electrical data (to be performed by the customer) No. Qunatity Description Position Frequency 3 x fuse 16 A (slow)) in the supply 1 pe r (trigge r...

Open the catalog to page 5
MultiBase 2078i - 6

Width dim. without door MultiBase 2078i | Code number 587.41.450-003 | Version 07.2017 Technical data By default, the system can only be used for a fixed number of users. If different users use the system – only on the upper parking spaces – (e.g. short-time parkers in office buildings or hotels) the Multiparking system needs to be adjusted. If required, would you please contact us. Units Page 3 Width dim. with door Function Low-noise power units mounted to rubber-bonded-to metal mountings are installed. Nevertheless we recommend that parking system’s garage be built separately from the...

Open the catalog to page 6
MultiBase 2078i - 7

Width dim. without door Page 3 Width dim. with door Function Page 4 Load plan Installation Electrical installation Technical data To be performed by the customer Description Safety fences Any constraints that may be necessary according to DIN EN ISO 13857 in order to provide protection for the park pits for pathways directly in front, next to or behind the unit. This is also valid during construction. Railings for the system are included in the series delivery when necessary. Numbering of parking spaces Consecutive numbering of parking spaces. Building services Any required lighting,...