Product catalog summary
System-Specific Corrosion Protection
The document outlines the corrosion protection measures for the ParkBoard PQ parking pallets. Key components such as platform base sections, side members, access plates, cross members, and the rail system are hot galvanized according to DIN EN ISO 1461, with varying layer thicknesses. Additional coatings are applied to certain parts for enhanced protection.

General Information
KLAUS Multiparking systems comply with European safety guidelines and standards, including the Machinery Directive and DIN EN 14010. Corrosion protection follows DIN EN ISO 12944, specifically for corrosion category C 3, suitable for moderate environments. The document emphasizes the importance of assessing local conditions to determine the appropriate corrosion category.

Period of Protection and Maintenance
The protection period is not a warranty but a guideline for maintenance planning, with a medium durability rating of 5-15 years. Maintenance may be required earlier due to environmental factors. The company guarantees a maximum rust level of Ri 3 within 4 years under a service contract, provided proper maintenance is conducted.

Coating System
The coating system adheres to DIN EN ISO 12944-5 standards, with powder coatings tested for compliance. Galvanized surfaces meet DIN ISO 1461 and DIN EN 13326 standards.

Wear and Tear Minimization
Recommendations to minimize damage include keeping the pit dry, ensuring ventilation, regular cleaning, timely repairs, and preventing salt exposure.

Galvanized Platform Base Sections
The document advises on the care of galvanized surfaces, particularly against aggressive winter conditions. Regular washing is recommended to prevent zinc compound build-up and maintain the protective layer.

Cleaning and Maintenance
KLAUS offers cleaning and maintenance plans under their PLUS system service contract.

Claims for Defects
Warranty claims exclude wear and tear from usage, with specific claim periods detailed in the company's offer.
See more

Catalog excerpts

CROSSWISE MOVEABLE PARKING PALLETS-1

HiLine Corrosion Protection Crosswise Moveable Parking Pallets ParkBoard PQ Code number 587.26.190-004 I Version 01.2016 I © KLAUS Multiparking I We reserve the right to make technical changes

 Open the catalog to page 1
CROSSWISE MOVEABLE PARKING PALLETS-2

1. System-specific corrosion protection Platform base sections Side members Platform base sections: StandardGrip: Hot galvanized according to DIN EN ISO 1461, layer thickness approx. 45 µm. Side members: Hot galvanized according to DIN EN ISO 1461, layer thickness approx. 55 µm. Acces plates: Hot galvanized according to DIN EN ISO 1461, layer thickness approx. 55 µm with additional orange powder coating (epoxide/polyester base) RAL 2000, dry film thickness approx. 60 – 80 µm. Access plate Cross members: Hot galvanized according to DIN EN ISO 1461, layer thickness approx. 55 µm. Rail system: Hot...

 Open the catalog to page 2
CROSSWISE MOVEABLE PARKING PALLETS-3

KLAUS Multiparking premium parking systems are subject to the European Parliament’s 2006/42/EG guidelines and the counsel of 17th May 2006 regarding machines (Machinery Directive) as well as DIN EN 14010 – safety of machines – equipment for power-driven parking of vehicles – Safety and EMW requirements regarding design, manufacture, assembly and activation. For the corrosion protection – described in detail below – DIN EN ISO 12944 applies. Individual components were assessed by us according to their functional and technical type and appropriate corrosion protection was specified. In accordance...

 Open the catalog to page 3
CROSSWISE MOVEABLE PARKING PALLETS-4

Galvanized platform base sections: Please note the following points for galvanized surfaces: ■ When using the platform base sections as parking spaces on KLAUS Multiparking Parking Systems, the zinc surface is subject to the extremely aggressive influences of water mixed with melting agents (e.g. road salt), particularly in the winter months. This inevitably leads to the zinc reacting with the melting agent mixtures. ■ This results in white marks made up of various zinc compounds (zinc oxide, zinc hydroxides, zinc chloride, etc.), which, if not removed, become encrusted on the surface and are...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.