Product catalog summary
Specification and Design: The Multideck 50-V2 is a 'dovetail' profile deck with a depth of 50mm, capable of spanning up to 4 meters without temporary supports. It offers design efficiency with various gauge thicknesses, quicker installation, and technical support via Kingspan Toolkit software.
Material Specification: The steel complies with BS EN 10143 and BS EN 10326: 2004, with a minimum yield strength of 350N/mm2 and a coating mass of 275g/m2.
Concrete Specification: Load/span tables are based on Grade C25/30 concrete with a design strength of 30N/mm2. Normal weight concrete has a density of 2400kg/m3, while lightweight concrete is 1900kg/m3.
Reinforcement: Reinforcement is required to control cracking, following BS 5950: Part 4 1994, with options including mesh, bar reinforcement, and Dramix Steel Fibres.
Load Tables: Detailed load/span tables are provided for different gauges and slab depths, considering unpropped and propped conditions. Key factors include support width, construction stage load, and reinforcement requirements.
Fire Performance: Fire performance details are not included in the provided text but are likely covered in the full document.
Recommendations: Engineers should consult the Steel Construction Institute and MCRMA Technical Paper 13 for best practices in design and construction.
Overview: The document provides technical specifications and performance data for the Multideck 50-V2, a composite steel deck slab system, including load tables, fire resistance ratings, and acoustic performance predictions.
Specifications: Span capabilities and total applied load capacities are listed for different slab gauges (0.9mm, 1.0mm, and 1.2mm) and depths, indicating structural performance under various scenarios.
Fire Resistance: The Multideck 50-V2 offers fire resistance ratings of 1 hour, 1.5 hours, and 2 hours with normal weight concrete, applicable for unpropped spans, with specific software advised for propped spans.
Acoustic Performance: Predicted acoustic performance for airborne and impact sound is detailed, with DnT,w + Ctr ratings for airborne sound and L’nT,w ratings for impact sound. Performance varies based on slab depth and additional treatments.
Recommendations: Use Multideck Design software for single span lengths and Kingspan Toolkit Software for propped spans. Proper junction detailing is crucial to minimize flanking sound.
Additional Notes: Acoustic performance values are based on a minimum concrete density of 2350 kg/m3. Lightweight concrete may reduce acoustic performance by 2 to 3 dB.
See more

Catalog excerpts

Multideck 50-V2-1

Multideck 50-V2 Multideck 50-V2 is a ‘dovetail’ profile deck with a depth of 50mm providing spans up to 4m unpropped. Key benefits include: • Greater Design Efficiency The larger range of Multideck gauge thicknesses allow much closer matching of design requirements and deck performance. • Quicker Installation Contents Specification and Design 9 No temporary supports required under most conditions. A wide range of accessories allows for easy installation of ceilings and services. • Technical Support Load Tables 11 Fire Performance 17 Dramix® Load Tables 20 Kingspan Toolkit software includes comprehensive composite floor design software which allows the user to easily select the right Multideck solution. The design software is available for download from the web site www.kingspanstructural.com. The Multideck design department provides a comprehensive engineering and advisory service to specifiers and end users on the use of the Multideck range of composite decks. Two Towers, Arnhem, Netherlands. Photo Courtesy of MSW (UK) Ltd. 8

 Open the catalog to page 1
Multideck 50-V2-2

Multideck 50 Multideck 50-V2 Specification and Design Profile and Dimensions (mm) 600mm nominal 150mm 20mm 40mm 5mm 51mm 17mm gauge Gauge = 0.9mm, 1.0mm, 1.2mm Maximum length: 12 metres 15mm Section Properties per Metre Width Normal Thickness (mm) (kg/m2) 12.89 14.36 17.29 Sagging 0.126 0.141 0.170 Second Moment of Area (cm4/m) Steel Area (mm2/m) Sagging Hogging 16.7 mm 17.0 mm 17.4 mm (kN/m2) 0.90 1.00 1.20 Height to Neutral Axis Self Weight Ultimate Moment Capacity (kNm/m) 67.68 74.26 95.55 1605 1792 2165 6.50 7.50 9.10 6.30 7.40 8.90 Material Specification – 350N/mm2 Steel Reinforcement Steel...

 Open the catalog to page 2
Multideck 50-V2-4

Multideck 50 Multideck 50-V2 Load Tables When using load tables for Multideck 50-V2 please take into consideration the following notes: 1 The table shows the maximum span in meters of the Multideck product for the applied loads and slab depths shown. Values are shown for each gauge where the deck is single span or double spans, plus values for propped spans during construction. 12 Deflection under construction loading (wet concrete etc) has been limited to that stipulated in BS5950 Part 4 1994. At the composite stage the suggested maximum ratio of slab span to slab depth are 35 for NWC and 30...

 Open the catalog to page 4
Multideck 50-V2-8

Load Tables Lightweight Concrete Unpropped - Load / Span Table (Steel - 350N/mm2) Span Type (Support Condition) Depth Mesh Total Applied Load (kN/m2) SLS Total Applied Load (kN/m2) SLS Propped - Load / Span Table (Steel - 350N/mm2) Span Type Depth Mesh (Support Condition) (mm) Size Total applied load referred to in the above table is a working load based on combinations of live loads, finishes, ceilings, services and partitions (excluding slab self weight) Figures in red are maximum permissible spans in situations where there is one stud per trough. Permanent Support Temporary Support 1^.

 Open the catalog to page 8
Multideck 50-V2-9

Kingspan Multideck was used in the construction of the Meadowhall Extension in Sheffield, UK. Photo Courtesy of MSW (UK) Ltd. 16

 Open the catalog to page 9
Multideck 50-V2-10

Multideck 50 Multideck 50-V2 Fire Performance – Mesh 1 The fire resistance tables for Multideck 50-V2 on the following pages are based upon fire test data from full scale tests performed at the Warrington Fire Research Centre UK, May 1998. 2 All stated slab depths comply with the minimum fire insulation criteria of BS 476: Part 20 1987. 3 The composite slab is assumed to be continuous over one or more intermediate supports. i.e. minimum double span. 4 The fire resistance load tables are for continuous spans only with no propping. For propped and single span conditions use the Kingspan Toolkit...

 Open the catalog to page 10
Multideck 50-V2-13

Fire Resistance Dramix® Reinforced Concrete 20kg/m3 RC-80/60-BN Load Tables (see pages 101-103) 1 Hour Fire Rating - Normal Weight Concrete Total Applied Load (kN/m2) Total Applied Load (kN/m2) 1.5 Hour Fire Rating - Normal Weight Concrete 2.0 Hour Fire Rating - Normal Weight Concrete These tables are not applicable to slabs where the deck is supplied in single span lengths (use Multideck Design software to determine suitable bottom bar requirements). These values are for unpropped spans only. For cases where the deck is propped please use the Kingspan Toolkit Software.

 Open the catalog to page 13
Multideck 50-V2-15

Multideck 50-V2 Sound Attenuation Kingspan Structural Products have undertaken extensive testing on the acoustic performance of the Multideck range of composite steel deck slabs The testing was carried out on behalf of Kingspan Structural Products by the Steel Construction Institute and resulted in a comprehensive report ‘Acoustic Performance of Kingspan Composite Floors’ copies of which can be obtained from Kingspan Structural Products technical Department. Predicted Site Acoustic Performance of Floors with Multideck 50-V2 Slab depth (mm) Slab on deck with no ceiling and no floor treatment 120...