A Range of Fuel/Oil Separators for Peace of Mind Pollution Control Separators klargester.com A member of the
Open the catalog to page 12 Introduction Surface water drains normally discharge to a watercourse or indirectly into underground waters (groundwater) via a soakaway. Contamination of surface water by oil, chemicals or suspended solids can cause these discharges to have a serious impact on the receiving water. The Environment Regulators, Environment Agency, England and Wales, SEPA, Scottish Environmental Protection Agency in Scotland and Department of Environment & Heritage in Northern Ireland, have published guidance on surface water disposal, which offers a range of means of dealing with pollution both at source...
Open the catalog to page 23 Source control SUDS should be considered where possible The use of SUDS should be considered at all sites and they should be incorporated where suitable. SUDS can be used to polish the effluent from these separators before it enters the environment6 Yes Yes Yes Yes No Is there risk of oil contaminating the drainage from the site? Risk of infrequent light contamination and potential for small spills only, e.g. car park Source control SUDS must be considered and incorporated where suitable Risk of regular contamination of surface water run off with oil and/or risk of larger spills, e.g....
Open the catalog to page 34 Bypass Separator NSBD Range Nominal Flow Peak Drainage Silt Oil Length Dia. Access Base to Base to Standard Min. Standard Size (l/s) Flow Area (m2) Storage Storage Shaft Inlet Outlet Fall Inlet Pipework Rate PPG3 Capacity Capacity Diameter Invert Across Invert Diameter (l/s) (0.0018) Litres Litres Unit NSBD3 3 30 1670 300 45 1765 1225 750 1450 1350 100 500 160 NSBD4 4.5 45 2500 450 68 1765 1225 750 1450 1350 100 500 200 NSBD6 6 60 3335 600 90 1765 1225 750 1450 1350 100 500 200 NSBD8 8 80 4445 800 120 3065 1225 750 1450 1350 100 500 250 NSBD10 10 100 5560 1000 150 3065 1225 750 1450 1350...
Open the catalog to page 45 Full Retention Separator NS Range Features • Light and easy to install • 3-30 l/sec range independently tested and performance sampled, certified by the BSI • Class I and Class II designs • Inclusive of silt storage volume • Fitted inlet/outlet connectors • Oil alarm system available • Vent points within necks • Extension access shafts for deep inverts • Maintenance from ground level To specify a nominal size Full Retention Separator, the following information is needed:- • The calculated flow rate for the drainage area served. Our designs are based on the assumption that any...
Open the catalog to page 56 Washdown & Silt Separator Range Car Wash Silt Trap Ref. Total Max. Max. Length Diameter Access Base to Base to Standard Min. Standard Approx Capacity Rec. Flow Shaft Inlet Outlet Fall Inlet Pipework Empty (Litres) Silt Rate Dia. Invert Invert Across Invert Diameter (Kg.) (l/s) Unit W1/012 1200 600 3 1310 1225 460 1150 1100 50 500 160 60 W1/020 2000 1000 5 2210 1225 460 1150 1100 50 500 160 120 W1/030 3000 1500 8 3060 1225 460 1150 1100 50 500 160 150 W1/040 4000 2000 11 3910 1225 460 1150 1100 50 500 160 180 W1/060 6000 3000 16 4530 1440 600 1360 1310 50 500 160 320 W1/080 8000 4000 22...
Open the catalog to page 67 Sizes & Specifications: Enviroceptor Backfill Total Drainage Max. Length Diameter Access Base to Base to Std. Min. Std. Empty Class Type Cap. Area Flow Shaft Inlet Outlet Fall Inlet Pipe- Weight (L) (M2) Rate Dia. Invert Invert Across Invert work (Kg.) (l/s) Unit I Concrete 10000 720 15 3915 2020 600 2180 2130 50 600 160 620 II Concrete 10000 720 15 3915 2020 600 2180 2130 50 600 160 620 • Oil storage volume • Coalescer (Class I unit only) • Automatic closure device • Oil alarm system available Installation The unit should be installed on a suitable concrete base slab and surrounded with...
Open the catalog to page 7Issue No. 4: September 2007 Heading Sub-heading Klargester Off-Mains Solutions • BioDisc® Sewage Treatment Plants • Aeroclere 6 Treatment Plants • AirFlow Sewage Treatment Plants • Sigma SuperSeptic Sewage Treatment Plants • HillMaster Package Pump Systems • Pumpstor24 Pumping Systems • Septic Tanks • Attenuation Systems • Cesspools • Grease & Silt Traps • Oil/Water Separators • Silage Effluent Tanks • Reed Beds • Rainwater Harvesting • Garden Watering Systems Certified Installers Strategically located throughout Ireland, Klargester Certified Installers are appointed following rigorous...
Open the catalog to page 8All Kingspan Environmental catalogs and technical brochures
-
Modular cold rooms
20 Pages
-
Klargester BioFicient
2 Pages
-
Klargester Biodisc® BD-BL
2 Pages
-
Pumpstor Pumping Systems
16 Pages
-
Klargester Septic Tanks
6 Pages
-
Separators Brochure
8 Pages
-
Klargester Biosafe 1-4
4 Pages
-
Klargester Biodisc® BA-BC
8 Pages
-
Klargester Biotec® 5-7
6 Pages
-
BIOSAFE
4 Pages
-
BioDisc®
8 Pages
-
Klargester Beta+ Septic Tank
2 Pages
-
Klargester Envirosafe
6 Pages
-
Klargester Biodisc® BE-BL
6 Pages
-
Septic Tank
6 Pages
-
PHORS Tank
2 Pages
-
Pumpstor24
6 Pages
-
Grease Traps: Brochure
2 Pages
-
Klargester Holding Tanks
2 Pages
Archived catalogs
-
RAINTRAP
8 Pages
-
BIODISC BA-BD 1-25PE WWTP
8 Pages
-
sludge separator
8 Pages