Catalog excerpts
SEPARATORS A RANGE OF FUEL/OIL SEPARATORS FOR PEACE OF MIND Let us help! Free professional site visit with friendly support and advice. helpingyou@klargester.com to make the right decision or call 028 302 66799 NCED ADVA OULDED M ROTO TRUCTION CONSSELECTED ON ODELS! M
Open the catalog to page 1Get in touch for a FREE professional site visit and a representative will contact you within 5 working days to arrange a visit. helpingyou@klargester.com to make the right decision or call 028 302 66799 Surface water drains normally discharge to a watercourse or indirectly into underground waters (groundwater) via a soakaway. Contamination of surface water by oil, chemicals or suspended solids can cause these discharges to have a serious impact on the receiving water. The standard refers to two ‘classes’ of separator, based on performance under standard test conditions. Bypass separators...
Open the catalog to page 2Is there risk of oil contaminating the drainage from the site? Risk of infrequent light contamination and potential for small spills only, e.g. car park Risk of regular contamination of surface water run off with oil and/or risk of larger spills, e.g. vehicle maintenance area, goods vehicle parking or vehicle manoevering5 Drainage will also contain dissolved oils, detergents or degreasers such as vehicle wash water and trade effluents, e.g. industrial sites Fuel oils are delivered to and dispensed on site, e.g. retail forecourts Very low risk of oil contamination, e.g. roof water Source...
Open the catalog to page 3Bypass APPLICATION Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g. I Lightly contaminated commercial areas. Class II separators are designed to achieve a concentration of 100mg/litre of oil under standard test conditions. PERFORMANCE Klargester were one of the first UK manufacturers to have separators tested to EN 858-1. Klargester have now added the NSB bypass range to their portfolio of certified...
Open the catalog to page 4Full Retention Kingspan Klai Full retention separators are used in high risk spillage areas such as: ■ Fuel distribution depots. Klargester were the first UK manufacturer to have the required range (3-30 l/sec) certified to EN 858-1 in the UK. The NSF number denotes the flow at which the separator operates. The British Standards Institute (BSI) have witnessed the performance tests of the required range of separators and have certified their performance, in relation to their flow and process performance to ensure that they met the effluent quality requirements of EN 858-1. Larger separator...
Open the catalog to page 5Washdown & Silt This unit can be used in areas such as car wash and other cleaning facilities that discharge directly into a foul drain, which feeds to a municipal treatment facility. If emulsifiers are present the discharge must not be allowed to enter an NS Class I or Class II unit. ■ Tool hire depots. ■ Construction compounds cleansing points. Such wash down facilities must not be allowed to discharge directly into surface water but must be directed to a foul connection leading to a municipal treatment works as they utilise emulsifiers, soaps and detergents, which can dissolve and...
Open the catalog to page 6Forecourt APPLICATION The forecourt separator is designed for installation in petrol filling station forecourts and similar applications. The function of the separator is to intercept hydrocarbon pollutants such as petroleum and oil and prevent their entry to the drainage system, thus protecting the environment against hydrocarbon contaminated surface water run-off and gross spillage. The unit should be installed on a suitable concrete base slab and surrounded with a concrete backfill. Structural grade units can also be supplied suitable for installation within a granular backfill (i.e. pea...
Open the catalog to page 7PROFESSIONAL INSTALLERS Klargester Accredited Installers Experience shows that correct installation successful operation of any wastewater treatment product. This is why using an installer with the experience and expertise to install your product is highly recommended. Services include : ■ Site survey to establish ground conditions and soil types ■ Advice on system design and product selection ■ Assistance on gaining environmental consents and building approvals ■ Tank and drainage system installation ■ Connection to discharge point and electrical networks Waste emptying and disposal...
Open the catalog to page 8All Kingspan Environmental catalogs and technical brochures
-
Modular cold rooms
20 Pages
-
Klargester BioFicient
2 Pages
-
Klargester Biodisc® BD-BL
2 Pages
-
Pumpstor Pumping Systems
16 Pages
-
Klargester Septic Tanks
6 Pages
-
Klargester Biosafe 1-4
4 Pages
-
Klargester Biodisc® BA-BC
8 Pages
-
Separators: Brochure
8 Pages
-
Klargester Biotec® 5-7
6 Pages
-
BIOSAFE
4 Pages
-
BioDisc®
8 Pages
-
Klargester Beta+ Septic Tank
2 Pages
-
Klargester Envirosafe
6 Pages
-
Klargester Biodisc® BE-BL
6 Pages
-
Septic Tank
6 Pages
-
PHORS Tank
2 Pages
-
Pumpstor24
6 Pages
-
Grease Traps: Brochure
2 Pages
-
Klargester Holding Tanks
2 Pages
Archived catalogs
-
RAINTRAP
8 Pages
-
BIODISC BA-BD 1-25PE WWTP
8 Pages
-
sludge separator
8 Pages