1. Catalogs
  2. KILZ
  3. KILZ HIGH BUILD® INTERIOR WATER-BASED PRIMER

KILZ HIGH BUILD® INTERIOR WATER-BASED PRIMER

KILZ HIGH BUILD®  INTERIOR WATER-BASED  PRIMER

KILZ HIGH BUILD® INTERIOR WATER-BASED PRIMER

Product catalog summary
Product Overview: KILZ High Build® Interior Water-Based Primer is designed for thicker application than most primers, providing a finish similar to a level 5 skim coat when sprayed. It incorporates KILZ® Premium's stainblocking technology and is suitable for all interior ceilings and walls, including paperless drywall.
Where to Use: Suitable for properly prepared interior surfaces such as brick, painted metal, glossy surfaces, drywall, paneling, stucco, masonry, plaster, and wood.
Compliance and Certifications: Complies with SCAQMD, CARB, OTC, LADCO, AIM, and LEED® standards. It does not meet MPI, GREENGUARD, GREEN SEAL™, CHPS, or NAHB/ICC NGBS certifications.
Product Specifications:
  • Composition: Acrylic Polymer
  • Weight Solids: 56.2% (+/-) 2%
  • Volume Solids: 39.8% (+/-) 2%
  • VOC: 90 g/L
  • Coverage: 100-200 sq. ft. per gallon
  • Recommended Film Thickness: Wet: 8.0-16.0 mils; Dry: 3.2-6.4 mils
Application Instructions:
  • Use eye protection and apply with a brush, roller, or sprayer.
  • Do not thin for stainblocking; a small amount of water may be added for other spray applications.
  • Apply at temperatures between 50°-90°F (10°-32°C).
  • Prime the entire surface for uniform topcoat appearance.
  • Dry Time: To touch in 30 minutes; recoat/topcoat in 1 hour.
Surface Preparation: Ensure surfaces are clean and free of dust, grease, and peeling paint. Special preparation is required for glossy surfaces, mold/mildew, and masonry.
Safety and First Aid: Contains ethylene glycol; harmful if swallowed. Use with adequate ventilation and avoid contact with eyes. In case of ingestion or difficulty breathing, seek medical attention immediately.
Warranty: Limited warranty offering replacement or refund if the product is found defective. Excludes labor costs and incidental damages.
Environmental and Disposal Information: Clean equipment with warm, soapy water. Dispose of waste according to local regulations and consider donating unused product.
See more

Catalog excerpts

KILZ HIGH BUILD®  INTERIOR WATER-BASED  PRIMER-1

HIGH BUILD AS OF 6/1/2011 COMPLIES OR IS CERTIFIED WITH: "Product may help projects qualify for LEED credits. Please see www.usgbc.org/LEED for additional details. TECHNICAL DATA SHEET KILZ HIGH BUILD® INTERIOR WATER-BASED KILZ High Build® primer Is a unique formulation that can be applied much thicker than most primers, and creates a finish equivalent to a fully prepared skim coat / level 5 finish when sprayed. As an added benefit, KILZ High Build utilizes the superior stalnblocklng technology behind KILZ® Premium primer. It can be used on all Interior ceilings and walls Including paperless drywall. Use on properly prepared Interior surfaces, such as: • Brick • Drywall • Painted Metal • Paneling Properly Prepared Glossy Surfacest FILL/MAX TINT "Tinting is not recommended for stainblocking Sheen levels depend on porosity and various surface Vehicle: Acrylic Polymer The addition of colorants may add VOCs. COVERAGE RATE gallon, depending on the surface texture, porosity and application method. Does not Include the loss of material from spraying, RECOMMENDED FILM THICKNESS PREMIUM APPLICATION TOOLS Airless Spray: Rough / Porous Surfaces: 1/2" - 3/4" nap Brush: Nylon/Polyester Blend SURFACE PREPARATION! •The surface must be clean, free of dust, grease, wax, peeling paint, mold, mildew and wallpaper paste. If washing Is necessary, use a non-soapy detergent or a TSP substitute. Rinse • Peeling or Checked Paint: Scrape off loose paint and sand to a smooth surface. Sanding or removal of paint containing lead Is • Glossy Surfaces: For maximum adhesion, scuff sand the surface thoroughly before prlmlng.f • Mold or Mildew Covered Surfaces: Wash the area with a mildew remover, rinse with water and allow to dry before priming. • Masonry, Brick, Stucco and Plaster: KILZ HIGH BUILD primer may be used on clean, dry, aged masonry surfaces. New masonry must be allowed to cure (dry) at least 30 days before applying KILZ HIGH BUILD primer. • Fire Restoration: It Is critical to clean smoke damaged surfaces thoroughly before priming. Primary Recommendation: KILZ COMPLETE®, KILZ ODORLESS® or KILZ® ORIGINAL primers, •Apply as supplied using a brush, roller or • Do not thin for stainblocking applications. A small amount of water may be added for other spray applications. • Only apply If surface, air and product tempera- • Stir thoroughly before and occasionally during • Prime the entire surface to ensure a uniform • Stainblocking: After priming, test for stain bleed-through by applying the topcoat to a small section. If the stain bleeds through the topcoat, apply a second coat of primer and test again before topcoatlng the entire area. If bleeding continues, a longer dry time Is needed before topcoatlng. • Tinting: Not recommended for stainblocking applications. KILZ HIGH BUILD primer may be tinted with up to 2 ounces of universal colorant per gallon for non-stalnblocklng projects. Tinting to a lighter shade than the • When using an airless sprayer, backrolling Is not required and will cause surface defects, Application at lower temperatures, high humidity or poor ventilation will affect dry time. This information is provided "as is" and no representations or warranties, either express or implied, of merchantability, fitness for a particular purpose or of any other nature are made with respect to this information or to any product referred to in this information. For MSDS or to consult with a technical service representative, call 1-866-PRIMER-1.

 Open the catalog to page 1
KILZ HIGH BUILD®  INTERIOR WATER-BASED  PRIMER-2

TECHNICAL DATA SHEET KILZ HIGH BUILD® INTERIOR WATER-BASED • Clean equipment and paint spatters with warm, soapy water. • If spilled, contain material and remove with an inert absorbent. Dispose of contaminated absorbent, container and unused product in accordance with all current federal, state and local regulations. • Do not dispose of this product down a drain, • Please consider donating any unused product. • For recycling or disposal Information, contact your local household refuse collection service, LIMITED WARRANTY If this product is found to be defective upon inspection by its representative,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.