Overview: The document provides comprehensive information on wastewater lifting stations, including specifications, installation procedures, and product options for various applications. It covers systems for wastewater with and without sewage, submersible pumps, and control units.
Specifications: Key specifications include particle size requirements for pumps (maximum 10 mm for grey water and 40 mm for black water), pressure connection options, pumping height, voltage, and certification standards such as EN 12050. The document also highlights the importance of pumping volume and explosion protection.
Installation Options: Lifting stations can be installed indoors or outdoors, with options for free-standing, concrete floor, or underground installations. The choice of installation impacts space usage, noise levels, and maintenance access.
Pump Types: The document distinguishes between non-chokable pumps for solid and fibrous materials and macerator pumps for long fibers and solid bodies.
Control and Monitoring: KESSEL offers a TeleControl system for remote monitoring of pump activity via GSM, providing updates to operators, facility managers, and plumbers.
Level Measurement: Various sensors and probes are discussed, including float switches, hydrostatic sensors, optical probes, pressure sensors, and conductance probes, each with specific applications and limitations.
Standards: Relevant standards include EN 12056, EN 752, EN 13564, EN 1253-5, and EN 12050, covering drainage systems, backwater valves, and lifting stations.
Product Range: The document lists various KESSEL products, such as Aqualift F and S series, Minilift, and Ecolift, with specifications on power, pressure pipe diameter, and maximum pumping height.
Innovations: The Ecolift system is highlighted as an alternative to standard lifting stations, offering gravity-sloped drainage.
Individual Solutions: KESSEL provides custom solutions based on project-specific requirements, leveraging polyethylene technology.
Installation and Design: Lifting stations are designed for free-standing installation in frost-protected rooms, featuring a compact design suitable for renovation work and installation in existing pump sumps.
Control and Safety Features: Systems are equipped with a Comfort control unit with a self-diagnosis system (SDS) for maximum safety, integrated drain functions, and a TeleControl telemetric system for remote monitoring.
Accessories and Additional Features: Various accessories are available, including extension sections, gasket sets, and pressure pipe sets. Systems offer additional inlets for on-site connections and are designed to be odour-tight with integrated non-return valves.
Applications: Lifting stations are suitable for industrial, municipal, and private use, handling wastewater with or without sewage, ideal for basement drainage and installation in waterproof concrete.
Performance and Capacity: Different models offer varying tank volumes (50 to 450 liters) and pump capacities (1,400 to 5,500 Watts), designed to fit through standard doorways with modular components for flexibility.
Control Units: Mono and Duo control units are designed for wastewater level measurement, equipped with float switches, pressure sensors, and optical probes for alarm level measurement, available in 230 V and 400 V versions, with ATEX-certified models for explosive environments.
Pumping Stations: The Aqualift F Duo pumping station handles wastewater with or without sewage, featuring a polyethylene chamber, odour-tight cover, and twin pumping system with submersible pumps, designed for frost-free installation with a backwater valve for protection against sewer backflow.
Lifting Stations: The Aqualift F XL lifting station has a 900-liter tank volume, suitable for free-standing installation, with twin pumps and a comfort control unit with multilingual digital display, designed for continuous duty with a pressure sensor for level control.
Installation and Safety: Installation guidelines emphasize anchoring in groundwater-endangered areas and safety measures for drop heights over 5 meters, specifying the use of reinforced corrugated chambers and access ladders compliant with safety standards.
Accessories: Various accessories enhance functionality and adaptability, including telemetric systems for remote monitoring, compressor sets for pressure control, and cable extension sets.
See more

Catalog excerpts

lifting stations-1

Wastewater lifting stations

 Open the catalog to page 1
lifting stations-2

3 Wastewater lifting stations Lifting stations for wastewater containing raw sewage Page Complete range for free-standing installation and for installation in a concrete floor Submersible pumps Lifting stations for free standing installation and for installation in a concrete floor Lifting stations for wastewater without sewage for fixed or mobile use, for residential, commercial, public and industrial applications Warning and control units Convenient monitoring and control of lifting stations and pumps Individual Solutions

 Open the catalog to page 2
lifting stations-3

Wastewater lifting stations – Everything the specialist needs to know Water flows upwards ? It often happens that wastewater cannot be drained with gravity because the sewer is higher than the drainage point in the basement. In this case a lifting station or pump must be used. Lifting stations pump the wastewater via pressure pipes into the sewer. Backwater level Particle size: The particle size of a pump specifies how many millimetres of free passage through the pump are available. According to the construction and testing regulations (EN 12050-2) for wastewater lifting stations for wastewater...

 Open the catalog to page 3
lifting stations-4

Wastewater lifting stations – Everything the specialist needs to know Installation options Example for installation in a concrete slab/floor Example for underground installation Lifting stations Example for installation in an exposed wastewater pipe Installation in a concrete floor Underground installation Free-standing lifting stations can be installed very easily and without a great deal of expenditure, and are suitable for single-family homes all the way up to larger commercial / industrial applications. Smaller systems can easily be placed in an existing basement room. Larger systems are...

 Open the catalog to page 4
lifting stations-5

Wastewater lifting stations – Everything the specialist needs to know General information and standards Level sensors / probes and alarm probes Lifting stations Level sensors and probes measure the level of the pumping medium in the collecting tank of a lifting station and trigger the pumping process of one or several pumps from a specified filling level onward. If the level in the collecting tank continues to rise, an acoustic warning signal can be give via an alarm probe (which also measures the level of the pumping medium). Pressure sensor The closed air volume within a pressure sensor is...

 Open the catalog to page 5
lifting stations-6

Wastewater lifting stations – Everything the specialist needs to know Selection criteria - lifting stations FOR WASTEWATER CONTAINING RAW SEWAGE AP 501 Ø 800/1000 Pressure pipe diameter Interior installation Exterior installation Input power Max. pumping height Lifting stations FOR WASTEWATER WITHOUT SEWAGE Aqualift S Ø 1000 Pressure pipe diameter Minilift Interior installation Exterior installation Input power Max. pumping height SmartSelect simply makes planning easier - calculation tool for lifting stations at smartselect.kessel.com

 Open the catalog to page 6
lifting stations-7

KESSEL-Product information Wastewater lifting stations Aqualift F Compact SmartSelect simply makes planning easier - calculation tool for lifting stations at smartselect.kessel.com Compact and powerful lifting stations Scan this QR code to directly view the corresponding product video. Single- / Twin station 40 liter tank volume Wastewater lifting stations Aqualift F Compact for installation in a concrete floor Lifting stations CHAMBER READY FOR UNDERGROUND INSTALLATION The telescopic upper section makes flexible adaptation to the required installation depth possible. Upper section can be turned,...

 Open the catalog to page 7
lifting stations-8

Single station 40 liter tank volume Twin station 40 liter tank volume Lifting station for wastewater disposal in a single toilet Small lifting station Minilift F Wastewater lifting stations Aqualift F Compact for free-standing installation in frost protected rooms for free standing installation The drain contained in the cover drains all surface water. Even in the event of a pipe burst or flooding, the pump discharges water out of the house and into the sewer. Lifting stations INTEGRATED DRAIN FUNCTION MAXIMUM SAFETY THANKS TO CONTROL UNIT WITH SDS The intelligent control unit with integrated...

 Open the catalog to page 8
lifting stations-9

Lifting stations for wastewater with or without sewage Aqualift F Compact Mono Installation in a concrete slab/floor Illustration and dimensioned drawing Illustration shows Lifting stations Illustration shows Products Input power Article description Lifting station Aqualift F Compact Mono / Duo for installation in a concrete slab/floor, with recessed cover for on-site tiling and drain Installation depth (D) 490 to 600 mm With odour trap, sealing water height 50 mm With lateral inlet Ø 110 With telescopic upper section for free height and level adjustment, recessed cover for on-site tiling, made...

 Open the catalog to page 9
lifting stations-10

Lifting stations for wastewater with or without sewage Installation example Aqualift F Compact Professional advantages Plug & play Comfort control unit with self-diagnosis system SDS for maximum safety. Integrated drain function to drain surface water. Continual drainage even in the event of incoming flood water or a pipe burst. Variable upper section rotatable, tiltable and height adjustable Installation in waterproof concrete. Gasket set (Art. # 83 023) to prevent groundwater infiltration. ቢ Lifting station ባ Pressure pipe set (Art. # 28 040) ቤ Extension section ብ Gasket set ቦ Control unit...

 Open the catalog to page 10
lifting stations-11

Lifting stations Aqualift F Compact Accessories Outer diameter Ø (mm) Extension section with centre flange with elastomer sealing sheet made of NK/SBR Ø 800 mm, incl. screws for article numbers: 28 701-C, 28 704-C Extension section with flange and counter flange for connection to an on-site sealing sheet made of polymer, incl. screws max. extension 140 mm Illustration and dimensioned drawing Article description For models made on or after Jan 2011 Cover plate, surface water tight Class A 15 With drain Ø 75, includes Multistop odour, foam, rodent and insect stop incl. gasket 1 recessed for on-site...

 Open the catalog to page 11
lifting stations-12

Lifting stations Aqualift F Compact When multiple extension sections are used make sure that access to valve is still possible ! Extension section made of polymer, max. extension 180 mm, incl. gasket for article numbers: 28 701-C, 28 704-C Gasket set for installation in waterproof concrete Illustration and dimensioned drawing Audible alarm 20 m cable length suitable for all control units Potential-free contact suitable for all control units 230 V: Wastewater station Aqualift F, Wastewater station Aqualift F Compact, Lifting station Aqualift F Mono 230 V Compressor set for use in combination with...