Hybrid lifting stations
1 / 20Pages

Catalog excerpts

Hybrid lifting stations - 1

Hybrid lifting stations

Open the catalog to page 1
Hybrid lifting stations - 2

Backwater pumping station Pumpfix F Hybrid lifting stations 2 Hybrid lifting stations For private and commercial applications. For gravity-fed wastewater pipes within or outside buildings. Backwater lifting station Ecolift XL For private and commercial applications. For gravity-fed pipes within or outside buildings.

Open the catalog to page 2
Hybrid lifting stations - 3

Scan this QR code to directly view the corresponding product video. Hybrid Lifting Stations Everything specialists need to know Hybrid lifting stations Constant running of a standard lifting station even with gravity sloped drainage. Why ? Lifting stations are often installed as a safety measure even though gravity sloped drainage is available. The disadvantage is that these systems must pump every single litre of collected wastewater. This leads to constant operation of the pumps, high energy usage, wear and tear on the system as well as nuisance noise - with the new KESSEL Hybrid Lifting...

Open the catalog to page 3
Hybrid lifting stations - 4

Hybrid Lifting Stations Everything specialists need to know Hybrid lifting stations Installation possibilities Example for installation in an exposed wastewater pipe Example for installation in a concrete slab/floor Example for underground installation Exposed installation Installation in a concrete floor Underground installation Ideal for the renovation of old buildings which are in danger of backwater - the low-cost, clean and standard-conform solution for retrofitting backwater units ! To avoid the complete wastewater pipes having to be rerouted in expensive construction work, we...

Open the catalog to page 4
Hybrid lifting stations - 5

KESSEL-Product information Backwater pumping stations Pumpfix F for domestic applications Scan this QR code to directly view the corresponding product video. Hybrid lifting stations SmartSelect simply makes planning easier - calculation tool for lifting stations at smartselect.kessel.com Backwater valve and lifting station in one Backwater pumping station Pumpfix F Installation in the concrete slab/floor COVERS CAN BE INDIVIDUALLY TILED No open pump sump or maintenance space required per EN 12056, Part 4 -means more living space VENTILATION Integrated ventilation eliminates the requirement...

Open the catalog to page 5
Hybrid lifting stations - 6

Hybrid lifting stations Backwater pumping stations Pumpfix F Installation in an exposed wastewater pipe PLUG & PLAY COMFORT CONTROL UNITS INTEGRATED DRAIN FUNCTION TO DRAIN SURFACE WATER with self-diagnosis system SDS and multilingual display (EN, DE, FR, IT, PL, NL) - can be connected without a qualified electrician. Continual drainage even in the event of a basement flooding TeleControl telemetric system for relaying full text messages to mobile phones available as accessory. NEW COMFORT VERSION FOR Ecolift XL AND Pumpfix F with multilingual (EN, DE, FR, IT, PL, NL) digital display for...

Open the catalog to page 6
Hybrid lifting stations - 7

Hybrid Lifting Stations for wastewater with or without sewage Pumpfix F Komfort Installation in a concrete slab/floor Hybrid lifting stations Illustration and dimensioned drawing Article description Products Outer diameter Ø (mm) Backwater pumping station Pumpfix F Komfort 1 for wastewater with or without sewage made of polymer, with telescopic upper section for continuous height- and level adjustment For installation in a concrete slab/floor 2 for installation depth (D) from 486 - 640 mm 1 with recessed cover for on-site tiling and drain (X) 2 with black cover and drain (S) With surface...

Open the catalog to page 7
Hybrid lifting stations - 8

Hybrid Lifting Stations for wastewater with or without sewage Installation example Pumpfix F Komfort Professional advantages Plug & play Comfort control unit with self-diagnosis system SDS for maximum safety. Integrated drain function to drain surface water. Installation in waterproof concrete. Gasket set to prevent groundwater infiltration. ቢ Backwater pumping station ባ Control unit Installation body with only 9 mm gradient. Ideal for renovation work. ቤ Sealing gasket set Pumpfix F pumps against backwater and discharges surface water. It protects drainage fixtures such as shower, sink,...

Open the catalog to page 8
Hybrid lifting stations - 9

Hybrid Lifting Stations Pumpfix F Extension section with flange and counter flange for connection to an on-site sealing sheet made of polymer, incl. screws max. extension 140 mm Extension section made of polymer, max. extension 180 mm, incl. gasket for article numbers: 24 100 X/S, 24 125 X/S, 24 150 X/S, 24 200 X/S Gasket set for installation in waterproof concrete consisting of: Counter flange made of polymer, incl. screws, elastomer waterproof membrane in NK/SBR Ø 800 mm for article numbers: 24 100 X/S, 24 125 X/S, 24 150 X/S, 24 200 X/S Potential-free contact Change-over contact 42 V /...

Open the catalog to page 9
Hybrid lifting stations - 10

Hybrid Lifting Stations Pumpfix F with integrated grating, black for article numbers: 24 100 S, 24 125 S, 24 150 S, 24 200 S Multistop odour, foam, rodent and insect stop for article numbers: 83 045 and 83 046 Hair filter made of polymer for article numbers: 83 045 and 83 046 Upper section made of polymer, max. extension 180 mm, height adjustable Cover plate, surface water tight Class A 15 With drain Ø 75, includes Multistop odour, foam, rodent and insect stop incl. gasket 1 recessed for on-site tiling, grey, for tile thicknesses of 18 mm for article numbers: 24 100 X, 24 125 X, 24 150 X,...

Open the catalog to page 10
Hybrid lifting stations - 11

KESSEL-Product informations Hybrid lifting station Ecolift XL for commercial / industrial applications Hybrid lifting stations SmartSelect simply makes planning easier - calculation tool for lifting stations at smartselect.kessel.com The new hybrid lifting station Ecolift XL Scan this QR code to directly view the corresponding product video. Hybrid lifting station Ecolift XL For free standing installation - Page 68 ENGINEERING SYSTEM BASE For indoor / free standing installation, for installation in a concrete floor, or outdoor underground installation in combination with the engineering...

Open the catalog to page 11
Hybrid lifting stations - 12

Hybrid lifting stations Hybrid lifting station Ecolift XL For minimum installation depth - Page 66 For installation depths up to 5 m - Page 68 Hybrid lifting station Ecolift XL ENGINEERING SYSTEMS CHAMBER For use in combination with the Ecolift XL Hybrid Lifting Station for installation in the concrete slab or outdoors underground PRESSURE OUTLET CONNECTION Quick-release, no tools required INLET / OUTLET Standard size Ø 160 mm (OD) CHAMBER COVERS Available in a stainless steel class A/L15 (tileable or not tileable) or in load classes B and D Available with up to two motorized backwater...

Open the catalog to page 12

All KESSEL catalogs and technical brochures

  1. Tailor-made

    24 Pages

  2. Separators

    57 Pages

  3. Catalogue3.2

    326 Pages

  4. Catalogue 3.1

    310 Pages

  5. Separators

    30 Pages

Archived catalogs