1. Catalogs
  2. KESSEL
  3. Backwater protection

Backwater protection

Backwater protection
1 / 36 PagesView full catalog

Backwater protection

Product catalog summary
Backwater Protection Overview
Backwater protection is crucial for preventing flooding in buildings during heavy rain or sewage system failures. The document outlines solutions such as premium and classic backwater valves, and installation options for both new constructions and renovations.
Understanding Backwater
Backwater occurs when sewage systems cannot handle heavy rainfall, leading to potential flooding in basements. Causes include blockages, pump failures, and high water levels in nearby streams or rivers. Effective protection involves using backwater valves or lifting stations to prevent wastewater from entering buildings.
Product Selection and Installation
Choosing the right backwater protection depends on the type of wastewater (black or grey water) and the building's drainage system. Options include installing backwater valves inside buildings or in external chambers to save space. Retrofitting is possible for older buildings to enhance protection.
Standards and Regulations
Compliance with EN standards is crucial for backwater protection systems. The document details various types of backwater valves as per EN 13564, highlighting their applications and installation requirements.
Premium Backwater Valves
Premium valves, such as Pumpfix F and Staufix FKA, offer advanced features like motor-driven flaps and integrated pumps for effective wastewater management during backwater events. These systems are designed for easy installation and maintenance.
Installation Examples
Illustrations provide guidance on installing backwater protection systems in different scenarios, including exposed pipes, concrete floors, and underground setups.
Additional Solutions
KESSEL offers comprehensive systems, including lifting and pumping stations, to complement backwater valves. These solutions ensure reliable protection against backwater in various building types.
Specifications
The Pumpfix F and Staufix FKA systems are equipped with a Comfort control unit featuring a self-diagnosis system (SDS) for enhanced safety. They are suitable for installation in both concrete slabs and exposed wastewater pipes. The systems are compliant with EN 13564 standards, ensuring reliable performance.
Installation and Functionality
The Pumpfix F Komfort system is designed for easy installation, especially when wastewater pipes are exposed across basement floors. It operates by discharging wastewater through gravity under normal conditions and activating a pump during backwater events. The Staufix FKA Komfort features a motorized backwater valve that seals during backwater events and reopens automatically. Both systems include a sealing gasket set for installation in waterproof concrete.
Product Features
Key features include a plug-and-play control unit, integrated drain function, variable upper section for height adjustment, and a fully open pipe passage during normal conditions. The systems are designed for renovation work with a minimal gradient of 9 mm.
Accessories
The document lists various accessories, including gasket sets, extension sections, optical probes, and alarm systems, which enhance the functionality and installation flexibility of the backwater protection systems.
Professional Advantages
These systems offer a cost-effective solution for backwater protection, preventing potential property damage from basement flooding. The integrated SDS ensures regular and automatic functional testing, providing peace of mind for users.
Specifications
The document outlines the specifications for different backwater valves, including the Pumpfix F, Staufix FKA, and Staufix SWA models. These valves are designed for installation in concrete slabs or exposed pipes and are available in various diameters ranging from Ø50 to Ø200 mm. The valves are made of polymer, ensuring corrosion-free operation.
Procedures
Installation procedures are highlighted, emphasizing the ease of retrofitting and tool-free maintenance. The valves can be installed in both new constructions and renovations, with minimal drop between inlet and outlet for easy installation.
Standards and Compliance
The valves comply with EN 13564 standards, ensuring they meet the necessary requirements for backwater protection. The document advises checking local regulations for specific certification needs.
Recommendations
The document recommends using these backwater valves for protecting individual drainage fixtures like showers, sinks, and washing machines below the backwater level. It also suggests using the valves for wastewater systems without sewage to prevent flooding and rodent intrusion.
Conversion Kits
Several conversion kits are available, allowing for the upgrade of existing systems to include motorized backwater valves with pumps or twin flap systems. These kits enhance the flexibility and functionality of the installed systems.
Key Features
The valves feature self-closing flaps, stainless steel rodent protection, and are designed for easy maintenance. The modular design allows for straightforward installation and adaptation to various ground levels.
Applications
The valves are suitable for use in residential, public, municipal, and industrial sectors, providing protection against backwater and additional security against vermin.
Specifications and Installation Guidelines for Backwater Inspection Chambers
The document provides detailed specifications and installation guidelines for backwater inspection chambers designed for wastewater management. These chambers are constructed from polyethylene, ensuring durability and resistance to aggressive wastewater and root infiltration. They are suitable for underground installation and come with a 20-year warranty.
Specifications
The chambers are available in various heights (H1 to H5) and diameters (Ø 1000 and Ø 800). They feature a monolithic design with integrated access steps and are watertight. The chambers include triple 160 mm hub type gasketed inlets and spigot type outlets (Ø 160 mm and Ø 200 mm) compatible with PVC and PE-HD pipes.
Installation and Accessories
The chambers are designed for easy assembly with lightweight components and a simple connection technique. They can handle groundwater depths up to 2000 mm. Accessories include conversion kits for backwater valves (KESSEL Staufix SWA, FKA, and Pumpfix F), upper sections for height adjustment, and various cover plates (Class A/B/D).
Backwater Protection
The chambers are equipped with cleaning openings for the installation of KESSEL backwater valves. They ensure backwater-proof and gravity-fed wastewater flow from buildings to sewers. The document also describes hybrid lifting stations for sewage-free wastewater and rainwater, featuring motorized backwater flaps and optional gate valves for enhanced protection.
Professional Advantages
The system offers long-term reliability with resistance to sedimentary deposits and aggressive media. It includes standard connections for basement and roof drains, and the cover for garden installation is part of the supply scope.
See more

Catalog excerpts

Backwater protection-1

Backwater protection

 Open the catalog to page 1
Backwater protection-2

Backwater protection 1 Backwater protection Premium backwater valves with mechanical or motor-driven backwater flap and pump for draining wastewater with sewage, even during backwater. Classic backwater valves with mechanical backwater flaps for protection against backwater. Backwater valves in chamber for underground installation Frees up basement space by moving backwater protection to outside the house. Individual Solutions

 Open the catalog to page 2
Backwater protection-3

Backwater protection Backwater protection – Everything specialists need to know What is backwater ? All the outlet pipes from drainage fixtures in buildings (washing machines, showers, toilets etc.) are connected to the sewer, forming a linked pipe system. If the wastewater cannot flow freely through the sewer e.g. after heavy rainfall or due to blockages in the sewer pipes, it is pushed back into the connected outlet pipes and can flood all the areas of the house which are below the backwater level, including any fixtures and furnishings etc. Backwater is always possible For economic reasons,...

 Open the catalog to page 3
Backwater protection-4

The right product selection Heavy rainfalls more common Backwater protection Backwater protection – Everything specialists need to know The problem of backwater has always existed, because for economic and technical reasons, sewage pipes are designed for average rainfall. This means the storm sewage pipe can fill up very quickly in the event of a cloudburst. What is new is that meteorologists predict that heavy rainfalls will increase in future. The reason: global warming leads to more evaporation from the earth’s surface. This fills rain clouds which then discharge torrential rain. The selection...

 Open the catalog to page 4
Backwater protection-5

Installation possibilities Backwater protection Backwater protection – Everything specialists need to know Example for installation in an exposed wastewater pipe Example for installation in a concrete slab/floor Example for underground installation Exposed installation Installation in a concrete floor Underground installation Ideal for the renovation of old buildings which are in danger of backwater - the low-cost, clean and standard-conform solution for retrofitting backwater units ! To avoid the complete wastewater pipes having to be rerouted in expensive construction work, we recommend installing...

 Open the catalog to page 5
Backwater protection-6

Backwater protection Backwater protection – Everything specialists need to know Standards and regulations INFORMATION Which standards must be taken into account ? Do you require more detailed information ? Our Service Centre will be happy to help. Description Gravity drainage systems inside buildings and performance requirements Gravity drainage systems inside buildings. Wastewater lifting plants - layout and calculation. Gravity drainage systems outside buildings. Anti-flooding devices for buildings - requirements Gullies for buildings - closures for light liquids The six product types of EN...

 Open the catalog to page 6
Backwater protection-7

KESSEL-Product information Premium backwater valves and clean outs within buildings Backwater protection Scan this QR code to directly view the corresponding product video. Tried-andtrusted backwater protection re-defined Pumpfix F backwater valve with integrated pump SELECTION CRITERIA PREMIUM-BACKWATER VALVES Controlfix Installation in a concrete floor ? Exposed installation ? Central protection of several drains possible ? For wastewater containing raw sewage? For commercial apllication ? Wastewater disposal during backwater event ? Conversion (Upgrade) Products see page Premium backwater...

 Open the catalog to page 7
Backwater protection-8

Backwater protection 1 Staufix FKA motorised backwater valve VARIABLE UPPER SECTION Rotatable, tiltable and height adjustable Staufix SWA twin flap backwater valve PLUG & PLAY COMFORT CONTROL UNITS with self-diagnosis system SDS and multilingual display (EN, DE, FR, IT, PL, NL) - can be connected without a qualified electrician. TeleControl telemetric system for relaying full text messages to mobile phones available as accessory. INSTALLATION IN WATERPROOF CONCRETE Option, gasket set to prevent groundwater infiltration Installation body with only 9 mm gradient. Ideal for renovation work STAINLESS...

 Open the catalog to page 8
Backwater protection-9

Backwater pumping stations for wastewater with or without sewage Pumpfix F Komfort Installation in a concrete slab/floor Backwater protection Illustration and dimensioned drawing Article description Products Outer diameter Ø (mm) Backwater pumping station Pumpfix F Komfort 1 for wastewater with or without sewage made of polymer, with telescopic upper section for continuous height- and level adjustment For installation in a concrete slab/floor 2 for installation depth (D) from 486 - 640 mm 1 with recessed cover for on-site tiling and drain (X) 2 with black cover and drain (S) With surface water...

 Open the catalog to page 9
Backwater protection-10

Backwater pumping stations for wastewater with or without sewage Installation example Pumpfix F Komfort Professional advantages Backwater protection Plug & play Comfort control unit with self-diagnosis system SDS for maximum safety. Integrated drain function to drain surface water. Variable upper section rotatable, tiltable and height adjustable Installation in waterproof concrete. Gasket set to prevent groundwater infiltration. Installation body with only 9 mm gradient. Ideal for renovation work. ቢ Backwater pumping station ባ Control unit Pumpfix F pumps against backwater and discharges surface...

 Open the catalog to page 10
Backwater protection-11

Motorised backwater valve for wastewater with or without sewage Staufix FKA Komfort Installation in a concrete slab/floor Backwater protection Illustration and dimensioned drawing Products Outer diameter Ø (mm) Article description Backwater valve Staufix FKA Komfort for wastewater with or without sewage made of polymer, with telescopic upper section for continuous height- and level adjustment For installation in a concrete slab/floor for installation depth (D) from 486 - 640 mm 1 with recessed cover for on-site tiling (X) 2 with black cover (S) With surface water tight cover plate class A 15...

 Open the catalog to page 11
Backwater protection-12

Motorised backwater valve for wastewater with or without sewage Installation example Staufix FKA Komfort Professional advantages Backwater protection Plug & play Comfort control unit with self-diagnosis system SDS for maximum safety. Variable upper section rotatable, tiltable and height adjustable ቢ Backwater valve ባ Control unit Installation in waterproof concrete. Gasket set to prevent groundwater infiltration. Backwater protection even during construction phase thanks to 3-stage flap Freely suspended flap in the construction phase position. Backwater valve Staufix FKA as central backwater...

 Open the catalog to page 12

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.