Catalog excerpts
Kalzip® Roof Anchors Technical data sheet 10/06-3-004 Kalzip® roof anchor Kalzip® tapered roof anchor The products Areas of application The Kalzip roof anchors for straight and tapered Kalzip® roof anchors are only authorised for personal Kalzip sheets have been specially designed as a safety systems (they are not suitable for attaching Class A individual fixing device in accordance with loads) and depending on specification can be used DIN EN 795 for use with personal fall arrest systems. for straight and tapered Kalzip® sheets Kalzip® roof anchors can also be used as external and • with straight Kalzip® sheets: ® intermediate anchors for Class C design-approved fixing devices in accordance with DIN EN 795. On grounds of technical safety they are recommended for all buildings, in particular for recurrent main- suitable for all approved construction widths between 305 and 434 mm • with tapered Kalzip® sheets with a seam spacing of max. 600 mm (tested only up to 434 mm) tenance work (e.g. for building facilities services). Kalzip® roof anchors must only be attached onto When used as an external anchor the maximum load Kalzip® aluminium sheets. must not exceed 6.5 kN.
Open the catalog to page 1Technical data sheet 10/06-3-004 Technical Data stainless steel/aluminium Product advantages • Tested in accordance with DIN EN 795 (DMT) • High level of safety due to large load bearing • Large safety reserves • Versatile, depending on specification can be used for straight and tapered sheets • Quick and simple assembly • Penetration-free attachment The Kalzip® roof anchors have been tested by EXAM (for straight Kalzip® sheets) (for tapered Kalzip® sheets) The test report is available on request (only in German). Installation of the Kalzip® roof anchor and Kalzip® tapered roof anchor The...
Open the catalog to page 2All Kalzip catalogs and technical brochures
-
Kalzip® Solar Systems
12 Pages
-
Kalzip® systems
64 Pages
-
Kalzip Walkway systems
4 Pages
-
Kalzip-Nature-Roof
16 Pages
-
Roof and Facade systems
12 Pages
-
Kalzip® Liner roof systems
8 Pages
-
Kalzip® FC facade system
88 Pages
-
Kalzip® FC rainscreen
28 Pages
-
BIPVco
2 Pages
-
Kalzip FC rainscreen system
72 Pages
-
Kalzip FC rainscreen system
20 Pages
-
Kalzip delivery lead times
2 Pages
-
Kalzip Finishes and colours
8 Pages
-
Kalzip Luminaire Systems
8 Pages
-
Kalzip FC Facade Systems
8 Pages
-
Kalzip® vapour layer FR
2 Pages
-
Kalzip Installation Guideline
84 Pages
-
Kalzip Construction details
87 Pages
-
Kalzip national case studies
52 Pages
Archived catalogs
-
Colour your thinking
16 Pages
-
Kalzip foldable aluminium
12 Pages
-
Low - U - value systèm
4 Pages
-
TitanSilver product
2 Pages
-
Falzinc Roof & Facade Systems
12 Pages
-
Kalzip Solar Solutions
16 Pages
-
Kalzip wall systems product
4 Pages
-
Kalzip perforated solutions
4 Pages
-
Kalzip FC façade system
4 Pages
-
Achieving goals
22 Pages
-
Quality lasts
12 Pages
-
TitanSilver product
2 Pages
-
Kalzip Solar solutions
16 Pages
-
Kalzip wall systems
4 Pages
-
Kalzip XT
4 Pages
-
Kalzip perforated solutions
2 Pages
-
Kalzip perforated solutions
4 Pages
-
Kalzip Systems
72 Pages