KALZIP NBS FORMAT (H31) OUTLINE SPECIFICATION Acoustic Purlin Roof Construction 0.18 W/m2K U-Value Project Name: Reference: Specifier: Date: H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions 120 METAL STANDING SEAM ROOF: Acoustic Purlin Roof Construction 0.18 W/m2K U-Value -Support structure: Cold rolled steel purlins at maximum 1800mm centres -Bearing width: 58 mm minimum. -External sheets: -Manufacturer and reference: Kalzip Ltd -Product Reference: -Material: -Thickness: - Finish: Haydock Lane Haydock St.Helens Merseyside WA11 9TY Tel: 01942 295500 www.kalzip.co.uk Kalzip Aluminium Standing Seam 65/400 Aluminium alloy BS EN AW 3004 (AlMn1Mg1) 0.2% proof stress (Rp0.2) = 185 N/mm2 minimum. Ultimate tensile strength (Rm) = 220 N/mm2 minimum. 0.9 mm (nominal) Tolerance on thickness to be +0.05 mm and -0.025 mm. This is a class 2 thickness tolerance as per BS EN 508-2:2000. Mill Finished Natural Stucco Embossed
Open the catalog to page 1- Other requirements: -Accessories: -End laps: -Side laps: -Spacers: -Sub-purlin: Extruded Aluminium Alloy (EN AW-6063) Gable End Channel Extruded Aluminium Alloy (EN AW-6061) Gable End Hooks Extruded Aluminium Alloy (EN AW-6063) Tolerance Gable Clip Extrusion Extruded Aluminium Alloy (EN AW-6063) Flat Bar 22mm x 6mm Fabricated Aluminium Alloy (EN AW-3004),Ridge Closures (KZ 65/400) Extruded Aluminium Alloy (EN AW-6063) Drip Angle 40mm x 20mm Kalzip profile ridge fillers (KZ 65/400) Kalzip profile eaves fillers (KZ 65/400) Fabricated aluminium alloy (EN AW-3004) flashings – material and finish...
Open the catalog to page 2211 STRUCTURE: Support structure tolerances to be as per cladding manufacturer's 215 STRUCTURE: Do not fix cladding until final coats of paint have been applied to outer surfaces of the supporting structure. 217 PROTECTION: Store metal sheets under cover to keep dry and to prevent staining. Storing should be aj] in accordance with the sheet and panel manufacturer’s recommendations. 219 FASTENINGS GENERALLY : Type(s), size(s), material(s) and finish(es) as specified, or in the absence of such specification, as Recommended for the purpose by the cladding manufacturer. 221 FITTINGS AND ACCESSORIES...
Open the catalog to page 3-Product reference: -Thickness: -Density: -Installation: St.Helens Merseyside WA11 9TY Tel: 01942 295500 www.kalzip.co.uk Kalzip Acoustic Rockfibre Slab with ECOSETM Technology (White tissue faced) 30mm - 1 layer 100 kg/m3 Install and secure insulation as the roofing work proceeds ensuring continuity and that all edges are closed off and no gaps are left. Keep insulation dry at all times. Acoustic slabs should be laid in over-lapping chequerboard pattern when installed in double layer application -Manufacturer: -Product reference: -Material: -Vapour resistivity: -Sealant tape: -Size: -Continuity:...
Open the catalog to page 4-Installation: Locate where shown on drawings and wherever necessary to close off corrugation cavities from the outside and inside of the building. Ensuring a tight fit, leaving no gaps. 305 FIRE RESISTING PROFILE FILLERS -Types: To accurately match sheet profile. -Fixing method: Adhesive recommended by profile filler manufacturer. 410 FIXING SHEETS GENERALLY Cut sheets and flashings to give clean true lines, with no distortion. Remove burrs and any lubricant. Cut openings in sheets for outlets, vent pipes, flues, etc. to the minimum size necessary and as per cladding manufacturer’s recommendations....
Open the catalog to page 512 Pages
64 Pages
4 Pages
16 Pages
12 Pages
8 Pages
88 Pages
28 Pages
2 Pages
72 Pages
20 Pages
8 Pages
8 Pages
2 Pages
2 Pages
8 Pages
2 Pages
84 Pages
87 Pages
52 Pages
16 Pages
12 Pages
4 Pages
2 Pages
12 Pages
16 Pages
4 Pages
4 Pages
4 Pages
22 Pages
12 Pages
2 Pages
16 Pages
4 Pages
4 Pages
2 Pages
4 Pages
72 Pages