video corpo

Kalzip® FC rainscreen
28Pages

{{requestButtons}}

Catalog excerpts

Kalzip® FC rainscreen - 1

Kalzip® FC rainscreen Simple, flexible and economical

Open the catalog to page 1
Kalzip® FC rainscreen - 2

Refurbishment Rostock & Roeger Omnibus-Zentrum GmbH, Koblenz (D) Inhalt Kalzip® FC rainscreen -simple flexible and economical New buildings and refurbishment Product and system characteristics System options and components - General Modular click rails System accessories Refurbishment Spiegels GmbH, Nettetal (D) Architect: Engelbert HanRen Gewurzmanufaktur Spirit of Spice, Willich (D) Architect: Architekturburo Dewey + Blohm-Schroder HYBRID FC Facade -the innovative facade solution Aesthetics and economy Design options in execution The system in detail Kalzip® FC rainscreen system...

Open the catalog to page 2
Kalzip® FC rainscreen - 3

KALZIP® FC RAINSCREEN SIMPLE FLEXIBLE AND ECONOMICAL Kalzip® FC rainscreen is a non-penetrative façade system that incorporates a fast-to-install lightweight flat rainscreen panel, suitable for both new build and refurbishment projects. The main feature of the system is its flexibility which allows the installation of the profiles to be carried out in two directions, either from the top down or from the bottom up. The choice of panel mounting direction is one of the unique benefits which enables not only easier and faster installation compared to conventional panel systems, but also allows...

Open the catalog to page 3
Kalzip® FC rainscreen - 4

FC facade system - simple, flexible and economical New building and refurbishment Based on the versatile application options in combination with an easy construction design and the outstanding price/performance ratio, the attached and rear ventilated FC facade is the best construction-physical facade construction. It offers the largest possible heat protection; the aluminum material protects the building reliably and sustainably against weather influences and it gives a unique character to the building. The ventilation regulates the moisture balance, prevents a heat buildup and protects...

Open the catalog to page 4
Kalzip® FC rainscreen - 5

PRODUCT AND SYSTEM CHARACTERISTICSThe flexible FC rainscreen system made of aluminum with freely selectable installation direction and easy panel exchange Sophisticated and leading installation systems ■ Time-saving installation by latching the system components in - this is especially cost effective ■ Freely selectable installation direction from top to bottom or from bottom to top as well as - surface related - independent of adjacent panels. The benefit: The installation is in sync with the construction progress, connections and fit components can be installed retroactively - for...

Open the catalog to page 5
Kalzip® FC rainscreen - 6

Standard construction widths PC panel Intermediate construction widths FC panels (starting at 1000 m2 project size) Profile type: Kalzip FC Kalzip FC Kalzip FC Kalzip FC Kalzip FC Profile type: Profile thickness Profile thickness Micro lining Maximal 6.000 mm panel length for construction > 500 mm Maximal 6.000 mm panel length for construction > 500 mm ■J Fit panels/transition sheets (max. L= 6,000 mm) Profile type: Profile type: Fit panel - construction width Transition sheet - leg length Fit panel - construction width Transition sheet - leg length Special construction widths on request.....

Open the catalog to page 6
Kalzip® FC rainscreen - 7

Head bending Corner panels Corner panels can be produced as inner and outer corners with different angles. Specification Leg 1: min. 150 mm/max. 1,000 mm Leg 2: min. 300 mm/max. 2,000 mm As a standard, FC panels are delivered with head bending on both sides at no extra costs. On request, panels can also be produced without head bending.. Corner panel for outer corner (α min. 45°) Corner panel for inner corner (α min. 45°) Spessart Forum (D), Architect: Planungsbüro Bensing & Partner, Bad Soden-Salmünster

Open the catalog to page 7
Kalzip® FC rainscreen - 8

Perforated panels RV 6-8 Share of holes: min. 44%, max. 48% depending on the panel width Perforation diameter: 6 mm Deviating perforation on request.. Micro-lined panels RV 3-5 Share of holes: min. 29%, max. 31% depending on the panel width Perforation diameter: 3 mm Kalzip FC 30/400 with head bending and micro-lining Approx. 20 mm from the upper or lower panel end. Transition sheets without micro-lining

Open the catalog to page 8
Kalzip® FC rainscreen - 9

Kalzip FC Fassadensystem Kindertagesstätte Wolfenbüttel Architect: Stadt Wolfenbüttel, Amt für Stadtentwicklung, Planen und Bauen Technical data Colors and surfaces n tandard hues S HPC RAL 9006 30% gloss degree, thicknesses: 1.0 – 1.47 mm HPC RAL 9007 30% gloss degree, thicknesses: 1.0 – 1.47 mm HPC RAL 7016 3% gloss degree, thicknesses: 1.0 – 1.47 mm Other RAL, NCS, HPC hues and special hues on request, minimum volume 300 m² Anti-graffiti coating on request n urfaces S AluPlusPatina natural aluminum, thicknesses: 1.0 – 1.47 mm AluPlusPatina bronze B40, thicknesses: 1.0 – 1.47 mm...

Open the catalog to page 9
Kalzip® FC rainscreen - 10

Penetration-free fastening on modular raster rail Raster rail SE The raster click rail SE is a self-carrying rail, which can be used as a statically carrying profile and therefore it can be fastened at a substructure independent of the latch-in position. Raster rail SEL The raster rail SEL is also a carrying rail and it can be fastened directly at the L wall brackets by using the 50 mm long legs. An additional continuous profile is not required. 70 mm System depth with raster click rail SE 50 mm System depth with raster click rail SEL Distance caliper Using the distance caliper, raster...

Open the catalog to page 10
Kalzip® FC rainscreen - 11

Standard length short in mm 2.985 2.985 2.985 Number of hanging points 12 10 9 Standard long short in mm 5.935 5.935 5.935 Number of hanging points 24 20 17

Open the catalog to page 11
Kalzip® FC rainscreen - 12

Sophisticated system accessories for a perfect result Fixed-point clamp To guarantee a uniform vertical joint pattern, each panel must be fixated in its defined position by a system-related fixed-point clamp. The fixedpoint clamp can be re-released and fixated again after the installation and alignment of the panel, using an Allen wrench, if required, even through the horizontal panel joint. Guidance snapper The guidance snappers ensure a steady gap between the panels and therefore guarantee an even joint pattern. The use of guidance snappers is mandatory for very short panels and corner...

Open the catalog to page 12

All Kalzip catalogs and technical brochures

  1. BIPVco

    2 Pages

Archived catalogs

  1. Quality lasts

    12 Pages

  2. Kalzip XT

    4 Pages

  3. Kalzip Systems

    72 Pages