Catalogue

Catalogue
1 / 16 PagesView full catalog

Catalogue

Product catalog summary
Construction and Design: The System K 1060 PB features zinc-coated tubular steel supports mounted in floor plates, connected with a cross-connector, allowing for a modular system with adjustable leveling up to ±30 mm. The joints are electrically conductive according to VDE standards, and the system can be disassembled for inspection or retrofitting.
Technical Data: Module sizes are 1200 x 600 mm and 600 x 600 mm, with special sizes available. The system supports area loads of 15 kN/m² and 30 kN/m², and individual loads of 3 kN and 5 kN. Panel thickness is approximately 40 mm, with an overall height from 180 to 2500 mm. Fire protection options include F30, B2, B1, and A2.
Floor Panels: Made from high-density multi-layer chipboard or mineral fiber, panels are protected with synthetic edge strips and can be coated with aluminum or galvanized steel. Compatible floor coverings include PVC, linoleum, rubber, or textile fabrics, available in various colors and patterns.
Applications: Suitable for wiring cavities in control rooms, high and low-voltage systems, and transformer rooms. It can be used in switchgear cabinet substructures, double-floor systems with integrated cable trays, and vertical cable feeds.
Design and Construction: The support structure consists of zinc-coated tubular steel supports bonded or bolted to the floor, allowing for variable leveling. Floor panels are placed at corners on supports, connected with rods for higher load requirements. The system is designed for easy inspection and retrofitting, with removable panels and rods. Conductive sound insulation manages electrostatic charges.
System Components: Includes high-density chipboard or mineral fiber panels, synthetic edge strips, aluminum or steel sheets, conductive sound insulation, and various steel components. Floor coverings can be PVC, linoleum, rubber, or textile fabrics.
Technical Data: Panel module size is 600 x 600 mm, with special sizes available. Panel thickness is approximately 40 mm, with area loads from 10 to 30 kN/m² and individual loads from 3 to 5 kN. Overall height ranges from 80 to 1000 mm, with adjustable support structure. System weight varies from 35 to 70 kg/m², with fire protection options F30, B2, B1, and A2.
Floor Panels: Precision-milled for gap-free installation, protected with synthetic edge strips, and coated with aluminum or galvanized steel. A wide range of colors and patterns is available for floor coverings.
Application: Designed for wiring, communication cables, and air conditioning cavities in office spaces, computer centers, and telephone exchanges.
Add-ons: Includes stairs, railings, bulkheads, ramps, landings, ventilation panels, flush-mounted outlet sockets, skirting boards, cable management systems, and floor sealing options.
Ventilation Panels: Cooling air enters the room through swirl outlets, preventing drafts through air turbulence. Alternatives include perforated or steel ventilation plates with adjustable features.
Ventilation System Overview: Describes a ventilation system where cooling air is introduced from a false floor, entering the room through swirl outlets to prevent drafts. Alternatives include perforated or steel-ventilation plates with adjustable features.
Company Information: Kalthoff GmbH, located in Hagen, Germany, is responsible for this system. Contact details include phone, fax, email, and website for inquiries.
See more

Catalog excerpts

Catalogue-1

Konstruktion Die Konstruktion zur Auflage der Bodenplatten besteht aus verzinkten Stahlrohrstützen, die in Fußgelenken gelagert werden. Die C-Profile werden am Stützenkopf mit dem Kreuzverbinder verschraubt. Diese Verschraubung ist nach VDE elektrisch leitend ausgeführt. Die Rastergröße richtet sich nach der geforderten Tragfähigkeit. Die Nivellierung erfolgt stufenlos durch ein Einstellgewinde. Zur Revision oder zum Nachrüsten lassen sich die Bodenplatten und das Rastersystem ganz oder teilweise demontieren. Design The structure for supporting the floor panels consists of zinccoated tubular steel supports which are located in floor plates and are fitted on the head or support plate (cross-connector) with a threaded levelling device permitting a tolerance of ± 30 mm. According to load requirements, the supports are bolted to the C-profiles to form a suitably dimensioned modular system on which floor panels of suitable size are placed. The joint is electrically conductive in accordance with VDE. For inspection or retrofitment, the floor panels and, if necessary, the modular system can be wholly or partly disassembled and reassembled.

 Open the catalog to page 1
Catalogue-2

Konstruktion Die Konstruktion zur Auflage der Bodenplatten besteht aus verzinkten Stahlrohrstützen, die in Fußgelenken gelagert werden. Die C-Profile werden am Stützenkopf mit dem Kreuzverbinder verschraubt. Diese Verschraubung ist nach VDE elektrisch leitend ausgeführt. Die Rastergröße richtet sich nach der geforderten Tragfähigkeit. Die Nivellierung erfolgt stufenlos durch ein Einstellgewinde. Zur Revision oder zum Nachrüsten lassen sich die Bodenplatten und das Rastersystem ganz oder teilweise demontieren. Design The structure for supporting the floor panels consists of zinccoated tubular...

 Open the catalog to page 2
Catalogue-3

Anwendungsbeispiele Schaltschrank-Unterkonstruktionen mit Grundrahmen (Bild 1), Doppelboden-Anlagen mit integriertem Kabeltragsystem (Bild 2), Kabeltragsystem und vertikale Kabelzuführung (Bild 3) Application Switchgear cabinet subsstructure with base frame. (pic. 1), Double-floor systems with integrated cable tray system (pic. 2), Cable tray system and vertical cable feed (pic. 3). Hochverdichtete Mehrschichtenspanplatten oder Mineralstoffplatten. Kunststoff-Umleimer, 0,6 mm dick, leitend/isolierend Aluminiumfeinblech oder Stahlblech, Mineralstoff auch ohne Rückseitenbeschichtung 10 Stahl-Fußgelenk...

 Open the catalog to page 3
Catalogue-4

Anwendungsbeispiele Schaltschrank-Unterkonstruktionen mit Grundrahmen (Bild 1), Doppelboden-Anlagen mit integriertem Kabeltragsystem (Bild 2), Kabeltragsystem und vertikale Kabelzuführung (Bild 3) Application Switchgear cabinet subsstructure with base frame. (pic. 1), Double-floor systems with integrated cable tray system (pic. 2), Cable tray system and vertical cable feed (pic. 3). Hochverdichtete Mehrschichtenspanplatten oder Mineralstoffplatten. Kunststoff-Umleimer, 0,6 mm dick, leitend/isolierend Aluminiumfeinblech oder Stahlblech, Mineralstoff auch ohne Rückseitenbeschichtung 10 Stahl-Fußgelenk...

 Open the catalog to page 4
Catalogue-5

Anwendungsbeispiele Schaltschrank-Unterkonstruktionen mit Grundrahmen (Bild 1), Doppelboden-Anlagen mit integriertem Kabeltragsystem (Bild 2), Kabeltragsystem und vertikale Kabelzuführung (Bild 3) Application Switchgear cabinet subsstructure with base frame. (pic. 1), Double-floor systems with integrated cable tray system (pic. 2), Cable tray system and vertical cable feed (pic. 3). Hochverdichtete Mehrschichtenspanplatten oder Mineralstoffplatten. Kunststoff-Umleimer, 0,6 mm dick, leitend/isolierend Aluminiumfeinblech oder Stahlblech, Mineralstoff auch ohne Rückseitenbeschichtung 10 Stahl-Fußgelenk...

 Open the catalog to page 5
Catalogue-6

Konstruktion Die Konstruktion zur Auflage der Bodenplatten besteht aus verzinkten Stahlrohrstützen, die in Fußgelenken gelagert werden. Die C-Profile werden am Stützenkopf mit dem Kreuzverbinder verschraubt. Diese Verschraubung ist nach VDE elektrisch leitend ausgeführt. Die Rastergröße richtet sich nach der geforderten Tragfähigkeit. Die Nivellierung erfolgt stufenlos durch ein Einstellgewinde. Zur Revision oder zum Nachrüsten lassen sich die Bodenplatten und das Rastersystem ganz oder teilweise demontieren. Design The structure for supporting the floor panels consists of zinccoated tubular...

 Open the catalog to page 6
Catalogue-7

Konstruktion Die Konstruktion zur Auflage der Bodenplatten besteht aus verzinkten Stahlrohrstützen, die mit dem Rohboden verklebt oder verdübelt werden. Die Nivellierung erfolgt stufenlos durch ein Einstellgewinde. Die Bodenplatten werden an ihren Ecken auf den Stützköpfen aufgelegt. Bei höheren Belastungsanforderungen können die Stützköpfe mit Rasterstäben verbunden werden. Zur Revision oder zum Nachrüsten lassen sich die Bodenplatten und die Rasterstäbe demontieren. Zur Ableitung elektrostatischer Aufladungen sind die Stützköpfe mit einer leitfähigen Schalldämmauflage ausgerüstet. Design The...

 Open the catalog to page 7
Catalogue-8

Konstruktion Die Konstruktion zur Auflage der Bodenplatten besteht aus verzinkten Stahlrohrstützen, die mit dem Rohboden verklebt oder verdübelt werden. Die Nivellierung erfolgt stufenlos durch ein Einstellgewinde. Die Bodenplatten werden an ihren Ecken auf den Stützköpfen aufgelegt. Bei höheren Belastungsanforderungen können die Stützköpfe mit Rasterstäben verbunden werden. Zur Revision oder zum Nachrüsten lassen sich die Bodenplatten und die Rasterstäbe demontieren. Zur Ableitung elektrostatischer Aufladungen sind die Stützköpfe mit einer leitfähigen Schalldämmauflage ausgerüstet. Design The...

 Open the catalog to page 8
Catalogue-9

Hochverdichtete Mehrschichtenspanplatten oder Mineralstoffplatten Kunststoff-Umleimer, 0,6 mm dick, leitend/isolierend Aluminiumfeinblech oder Stahlblech, Mineralstoffplatten auch ohne Rückseitenbeschichtung Schalldämmauflage, leitfähig Kopf- oder Trageplatte Rohr, Ø 24 mm x 2 mm Flachmutter zur Arretierung der Höhe 10 Rasterstäbe für höhere Belastungsanforderung 11 Bodenbelag nach Wahl: z.B. PVC, Linoleum, Kautschuk, Textilbelag. Die hochverdichteten Mehrschichtenspanplatten oder Mineralstoffplatten werden im Werk so schablonengefräst, dass sie nach dem Verlegen fugenlos aneinander passen. Die...

 Open the catalog to page 9

All Kalthoff catalogs and technical brochures