1. Catalogs
  2. Jydepejsen A/S
  3. Technical Data PANORAMA

Technical Data PANORAMA

Technical Data PANORAMA
1 / 17 PagesView full catalog

Technical Data PANORAMA

Product catalog summary
Overview
This document provides a detailed technical data sheet for the PANORAMA stove, including its specifications, testing approvals, and installation guidelines.
Specifications
  • Testing and Approval: The stove is tested and approved by the Danish Technological Institute, meeting standards EN16510-1:2022 and EN16510-2-1:2022.
  • Type Classification: CA
  • Preferred Fuel: Wood logs with moisture content ≤ 25%
  • Nominal Heat Output: 7.4 kW
  • Efficiency: 75% with a seasonal efficiency of 65%
  • Energy Efficiency Class: A with an index of 99
  • Emissions: CO - 1250 mg/Nm³, NOx - 94 mg/Nm³, OGC - 70 mg/Nm³, Particulate - 14 mg/Nm³
  • Chimney Requirements: Recommended draught of 12 Pa, temperature class T450 G
  • Dimensions and Weight: 1500 x 398 x 398 mm, 178 kg
  • Safety and Compliance: Passed tests for reaction to fire, risk of fuel falling out, cleaning accessibility, and surface temperature.
Installation Guidelines
Minimum Installation Distances
  • Without Insulated Flue Pipe: Rear to combustible material - 500/400 mm, sides - 500/750 mm, top of door - 750 mm, front - 1000 mm.
  • With Insulated Flue Pipe: Rear to combustible material - 475/350 mm, sides - 475/700 mm, top of door - 750 mm, front - 950/900 mm.
These guidelines ensure safe installation and operation of the stove, minimizing risks associated with combustible materials.
Technical Specifications:
The stove has been tested and approved by the Danish Technological Institute under standards EN16510-1:2022 and EN16510-2-1:2022. It is classified as type BE and is designed to use wood with a moisture content of ≤ 25% as the preferred fuel. The nominal thermal power is 7.4 kW with an efficiency of 75% and a seasonal efficiency of 65%. The energy efficiency class is A with an energy efficiency index of 99. Emissions include CO at 1250 mg/Nm³, NOx at 94 mg/Nm³, OGC at 70 mg/Nm³, and particles at 14 mg/Nm³. The recommended chimney draft is 12 Pa, and the flue gas temperature is 354°C. The stove dimensions are 1500 x 398 x 398 mm, and it weighs 178 kg.
Installation Distances:
For stoves without an insulated flue pipe, the minimum distance from the back to combustible materials is 500/400 mm, from the sides 500/750 mm, and from the top of the door 750 mm. The front distance to combustible materials is 1000 mm. For stoves with an insulated flue pipe, these distances are slightly reduced.
Safety and Compliance:
The stove has passed tests for fire reaction (A1), risk of falling combustible material, accessibility for cleaning, and surface temperature. It is suitable for connection to a collective chimney.
See more

Catalog excerpts

Technical Data PANORAMA-1

PANORAMA DK: Teknisk datablad EN: Technical Data Sheet

 Open the catalog to page 1
Technical Data PANORAMA-2

DKTeknisk datablad - PANORAMA Ovnen er testet og godkendt af: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-1351

 Open the catalog to page 2
Technical Data PANORAMA-3

Opstillingsafstande (minimum) for ovne UDEN isoleret røgrør Afstand fra bagsiden af ovnen til brændbart (dR) Afstand fra siderne til brændbart (ds) Afstand fra toppen af lågen til brændbart (dc) Afstand fra fronten til brændbart (møbleringsafstand) (dp) Afstand fra front til brændbart i nederste frontstråleområde (dF) Afstand fra front til brændbart i sidefrontstråleområde (d L) Afstand fra lågens underkant til gulv (DB) Afstand til 45o hjørne væg (DS(C)) Afstand til ikke-brændbare vægge (Dnon) Opstillingsafstande (minimum) for ovne MED isoleret røgrør Afstand fra bagsiden af ovnen til brændbart...

 Open the catalog to page 3
Technical Data PANORAMA-4

DETechnisches Datenblatt - PANORAMA Der Ofen wurde gepruft und zugelassen von: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Norm: EN16510-1:2022 / EN16510-2-1:2022 DTI Referenz.: 1235-CPR-ELAB-1351

 Open the catalog to page 4
Technical Data PANORAMA-5

Mindestabstande fur Ofen OHNE isoliertes Rauchrohr

 Open the catalog to page 5
Technical Data PANORAMA-6

The stove has been tested and approved by: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-1351

 Open the catalog to page 6
Technical Data PANORAMA-7

Minimum installation distances for stoves WITHOUT insulated flue pipe

 Open the catalog to page 7
Technical Data PANORAMA-8

FR Fiche technique – PANORAMA Le poêle a été testé et approuvé par: DTI – Danish Technological Institute, Teknologiparken, Kongsvang Allé 29, DK-8000 Aarhus C Norme: EN16510-1:2022 / EN16510-2-1:2022 Référence DTI: 1235-CPR-ELAB-1351 Classification du type Combustible préféré Autres combustibles adaptés Puissance calorifique nominale Rendement Rendement saisonnier Fonction de chauffage indirect Classe d’efficacité énergétique (EEC) Indice d’efficacité énergétique (EEI) Émission de CO (à 13 % O₂) Émission de NOx (à 13 % O₂) Émission d’OGC (à 13 % O₂) Émission de particules (à 13 % O₂) Tirage de...

 Open the catalog to page 8
Technical Data PANORAMA-9

Distances minimales d’installation pour poeles SANS conduit isole

 Open the catalog to page 9
Technical Data PANORAMA-10

NOTeknisk datablad - PANORAMA Ovnen er testet og godkjent av: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-1351

 Open the catalog to page 10
Technical Data PANORAMA-11

Minimumsavstander ved installasjon av ovner UTEN isolert roykror

 Open the catalog to page 11
Technical Data PANORAMA-12

SE Tekniskt datablad – PANORAMA Kaminen är testad och godkänd av: DTI – Danish Technological Institute, Teknologiparken, Kongsvang Allé 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-1351 Typklassificering Föredraget bränsle Andra lämpliga bränslen Nominell värmeeffekt Verkningsgrad Säsongsverkningsgrad Indirekt värmefunktion Energieffektivitetsklass (EEC) Energieffektivitetsindex (EEI) CO-utsläpp (vid 13 % O₂) NOx-utsläpp (vid 13 % O₂) OGC-utsläpp (vid 13 % O₂) Partikelutsläpp (vid 13 % O₂) Rekommenderat skorstensdrag Rökgastemperatur med rökstos Skorstenstemperaturklass...

 Open the catalog to page 12
Technical Data PANORAMA-13

Minimiavstånd vid installation av kaminer UTAN isolerat rökrör Avstånd från baksidan av kaminen till brännbart material (dR) Avstånd från sidorna till brännbart material (ds) Avstånd från dörrens ovankant till brännbart material (dc) Avstånd från front till brännbart material (möbleringsavstånd) (dp) Avstånd från front till brännbart – nedre frontstrålningsområde (dF) Avstånd från front till brännbart – sidofrontstrålningsområde (dL) Avstånd från dörrens underkant till golv (DB) Avstånd till 45° hörnvägg (DS(C)) Avstånd till icke brännbara väggar (Dnon) Minimiavstånd vid installation av kaminer...

 Open the catalog to page 13
Technical Data PANORAMA-14

La stufa e stata testata e approvata da: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Norma: EN16510-1:2022 / EN16510-2-1:2022 DTI Rif.: 1235-CPR-ELAB-1351

 Open the catalog to page 14
Technical Data PANORAMA-15

Distanze minime di installazione per stufe SENZA tubo del fumo isolato

 Open the catalog to page 15
Technical Data PANORAMA-16

De houtkachel is getest en goedgekeurd door: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Norm: EN16510-1:2022 / EN16510-2-1:2022 Referentie DTI: 1235-CPR-ELAB-1351

 Open the catalog to page 16
Technical Data PANORAMA-17

Minimale installatieafstanden voor ovens ZONDER geisoleerde rookpijp

 Open the catalog to page 17
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.