1. Catalogs
  2. Jydepejsen A/S
  3. Technical Data COUNTRY

Technical Data COUNTRY

Technical Data COUNTRY
1 / 17 PagesView full catalog

Technical Data COUNTRY

Product catalog summary
Technical Data Sheet Summary

Testing and Approval: The stove has been tested and approved by the Danish Technological Institute, adhering to standards EN16510-1:2022 and EN16510-2-1:2022.

Specifications:
  • Type Classification: BE
  • Preferred Fuel: Wood logs with moisture content ≤ 25%
  • Nominal Heat Output: 4.2 kW
  • Efficiency: 81%
  • Seasonal Efficiency: 71%
  • Energy Efficiency Class: A+
  • Energy Efficiency Index: 108
  • CO Emission: 1492 mg/Nm³ at 13% O₂
  • NOx Emission: 105 mg/Nm³ at 13% O₂
  • OGC Emission: 111 mg/Nm³ at 13% O₂
  • Particulate Emission: 29 mg/Nm³ at 13% O₂
  • Recommended Chimney Draught: 12 Pa
  • Flue Gas Temperature: 275 °C
  • Chimney Temperature Class: T400 G
  • Flue Gas Mass Flow: 4.5 g/s
  • Operating Mode: Intermittent
  • Flue Outlet Diameter: 150 mm
  • Overall Dimensions: 575/765 × 440 × 380 mm
  • Stove Weight: 94/100 kg
  • Load Bearing Capacity: 20 kg
  • Reaction to Fire: A1
  • Risk of Fuel Falling Out: Passed
  • Electrical Safety: Not Applicable
  • Cleaning Accessibility: Passed
  • Surface Temperature: Passed
  • Suitable for Shared Flue System: Yes
  • Weight of Ember Bed: 355 g

Installation Distances:
Without Insulated Flue Pipe:
  • Rear to Combustible Material: 275 mm
  • Sides to Combustible Material: 450 mm
  • Top of Door to Combustible Material: 750 mm
  • Front to Combustible Material: 850 mm
  • Lower Frontal Radiation Zone: 440 mm
  • Bottom Edge of Door to Floor: 156 mm
  • 45° Corner Wall: 300 mm
  • Non-Combustible Walls: 50 mm

With Insulated Flue Pipe:
  • Rear to Combustible Material: 225 mm
  • Sides to Combustible Material: 425 mm
  • Top of Door to Combustible Material: 750 mm
  • Front to Combustible Material: 850 mm
  • Lower Frontal Radiation Zone: 440 mm
  • Bottom Edge of Door to Floor: 156 mm
  • 45° Corner Wall: 270 mm
  • Non-Combustible Walls: 50 mm
See more

Catalog excerpts

Technical Data COUNTRY-1

EN: Technical Data Sheet Side 2-3 Seite 4-5 Page 6-7 Page 8-9 Side 10-11 Sida 12-13 Pagina 14-15 Pagina 16-17

 Open the catalog to page 1
Technical Data COUNTRY-2

DKTeknisk datablad - COUNTRY Ovnen er testet og godkendt af: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-2549

 Open the catalog to page 2
Technical Data COUNTRY-3

Opstillingsafstande (minimum) for ovne UDEN isoleret røgrør Afstand fra bagsiden af ovnen til brændbart (dR) Afstand fra siderne til brændbart (ds) Afstand fra toppen af lågen til brændbart (dc) Afstand fra fronten til brændbart (møbleringsafstand) (dp) Afstand fra front til brændbart i nederste frontstråleområde (dF) Afstand fra front til brændbart i sidefrontstråleområde (d L) Afstand fra lågens underkant til gulv (DB) Afstand til 45o hjørne væg (DS(C)) Afstand til ikke-brændbare vægge (Dnon) Opstillingsafstande (minimum) for ovne MED isoleret røgrør Afstand fra bagsiden af ovnen til brændbart...

 Open the catalog to page 3
Technical Data COUNTRY-4

DETechnisches Datenblatt - COUNTRY Der Ofen wurde gepruft und zugelassen von: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Norm: EN16510-1:2022 / EN16510-2-1:2022 DTI Referenz.: 1235-CPR-ELAB-2549

 Open the catalog to page 4
Technical Data COUNTRY-6

The stove has been tested and approved by: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-2549

 Open the catalog to page 6
Technical Data COUNTRY-7

Minimum installation distances for stoves WITHOUT insulated flue pipe

 Open the catalog to page 7
Technical Data COUNTRY-8

FR Fiche technique – COUNTRY Le poêle a été testé et approuvé par: DTI – Danish Technological Institute, Teknologiparken, Kongsvang Allé 29, DK-8000 Aarhus C Norme: EN16510-1:2022 / EN16510-2-1:2022 Référence DTI: 1235-CPR-ELAB-1883-Rev. 1 Classification du type Combustible préféré Autres combustibles adaptés Puissance calorifique nominale Rendement Rendement saisonnier Fonction de chauffage indirect Classe d’efficacité énergétique (EEC) Indice d’efficacité énergétique (EEI) Émission de CO (à 13 % O₂) Émission de NOx (à 13 % O₂) Émission d’OGC (à 13 % O₂) Émission de particules (à 13 % O₂) Tirage...

 Open the catalog to page 8
Technical Data COUNTRY-9

Distances minimales d’installation pour poeles SANS conduit isole

 Open the catalog to page 9
Technical Data COUNTRY-10

NOTeknisk datablad - COUNTRY Ovnen er testet og godkjent av: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-2549

 Open the catalog to page 10
Technical Data COUNTRY-11

Minimumsavstander ved installasjon av ovner UTEN isolert roykror

 Open the catalog to page 11
Technical Data COUNTRY-12

SE Tekniskt datablad – COUNTRY Kaminen är testad och godkänd av: DTI – Danish Technological Institute, Teknologiparken, Kongsvang Allé 29, DK-8000 Aarhus C Standard: EN16510-1:2022 / EN16510-2-1:2022 DTI Ref.: 1235-CPR-ELAB-2549 Typklassificering Föredraget bränsle Andra lämpliga bränslen Nominell värmeeffekt Verkningsgrad Säsongsverkningsgrad Indirekt värmefunktion Energieffektivitetsklass (EEC) Energieffektivitetsindex (EEI) CO-utsläpp (vid 13 % O₂) NOx-utsläpp (vid 13 % O₂) OGC-utsläpp (vid 13 % O₂) Partikelutsläpp (vid 13 % O₂) Rekommenderat skorstensdrag Rökgastemperatur med rökstos Skorstenstemperaturklass...

 Open the catalog to page 12
Technical Data COUNTRY-13

Minimiavstånd vid installation av kaminer UTAN isolerat rökrör Avstånd från baksidan av kaminen till brännbart material (dR) Avstånd från sidorna till brännbart material (ds) Avstånd från dörrens ovankant till brännbart material (dc) Avstånd från front till brännbart material (möbleringsavstånd) (dp) Avstånd från front till brännbart – nedre frontstrålningsområde (dF) Avstånd från front till brännbart – sidofrontstrålningsområde (dL) Avstånd från dörrens underkant till golv (DB) Avstånd till 45° hörnvägg (DS(C)) Avstånd till icke brännbara väggar (Dnon) Minimiavstånd vid installation av kaminer...

 Open the catalog to page 13
Technical Data COUNTRY-14

La stufa e stata testata e approvata da: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Norma: EN16510-1:2022 / EN16510-2-1:2022 DTI Rif.: 1235-CPR-ELAB-2549

 Open the catalog to page 14
Technical Data COUNTRY-15

Distanze minime di installazione per stufe SENZA tubo del fumo isolato

 Open the catalog to page 15
Technical Data COUNTRY-16

De houtkachel is getest en goedgekeurd door: DTI - Danish Technological Institute, Teknologiparken, Kongsvang Alle 29, DK-8000 Aarhus C Norm: EN16510-1:2022 / EN16510-2-1:2022 Referentie DTI: 1235-CPR-ELAB-2549

 Open the catalog to page 16
Technical Data COUNTRY-17

Minimale installatieafstanden voor ovens ZONDER geisoleerde rookpijp

 Open the catalog to page 17
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.