Catalog excerpts
DUCT FANS КАНАЛЬНЫЕ ВЕНТИЛЯТОРЫ Duct fans are really useful solution in many ventilation installations because of their easy construction, easy assembly and the low costs of construction and operation. They connect the advantages of axial and radial fans because they keep the axial air flow direction with the possibility of overcome the bigger installation resistances. WKO fans operation is characterized by the low volume emitted to the environment. INTENDED USE Duct fans are designed for use them in the intake and exhaust ventilating installations made in the industrial and general building engineering. Flowing air can be polluted with the vapors and corrosive gases and polluted with the gases within the limits which are permitted by the environment protection regulations. Применение канальных вентиляторов является оптимальным решением во многих вентсистемах благодаря их простой конструкции, легкому монтажу и следовательно небольшим затратам на их монтаж и эксплуатацию. Канальные вентиляторы объединяют в себе преимущества осевых и центробежных вентиляторов, так как обеспечивают осевое направление потока воздуха с возможностью преодоления значительного сопротивления вентсистемы. Работа вентилятора WKO характеризуется низким уровнем шума, воздействующим на окружающую среду. ПРИМЕНЕНИЕ Канальные вентиляторы предназначены для применения в приточных и вытяжных вентсистемах на объектах промышленного и общего назначения. Воздух, проходящий через вентилятор, может содержать пар, пыль и коррозионные газы в пределах, допустимых нормами охраны окружающей среды. DEVICE DESCRIPTION Series of types of fans include 6 dimensions. Fans consist in: ›› casing made of plastic with the connecting spout to the ventilating installations ›› highly efficient plastic c
Open the catalog to page 1FANS BEHTM^flTOPbl FANS BEHTM^flTOPbl TECHNICAL DATA TEXHMHECKME flAHHblE Basic dimensions OcHOBHbie napaMeTpbi
Open the catalog to page 2ВЕНТИЛЯТОРЫ WKO-16 Motor / Двигатель Pc[Pa] / Pc[Па] Pc[Pa] / Pc[Па] Pc[Pa] / Pc[Па]
Open the catalog to page 3ВЕНТИЛЯТОРЫ WKO-31,5 Motor / Двигатель Pc[Pa] / Pc[Па] Громкость работы Noise level at point 1 / Громкость в точке 1 Acoustic energy directed to the duct from the suction and Acoustic pressure level in the fan environment Lp [dB(A)]* pressing side Lwa [dB(A)] Звуковая мощность по направлению к воздуховоду со Уровень звукового давления вокруг вентилятора Lp, дБ(A)* стороны нагнетания и всасывания Lwa, дБ(A) 64 47 65 49 68 53 69 55 70 57 73 * Acoustic pressure level in the fan environment from the distance of 1m at the accommodation acoustic absorption A=20m2 and directional
Open the catalog to page 4All JUWENT - SZYMANSKI - NOWAKOWSKI - JANIK SP. J. catalogs and technical brochures
-
floor convectors
40 Pages
-
HEAT EXCHANGERS
6 Pages
-
Product overview
9 Pages
-
rgs
12 Pages
-
wkp
12 Pages
-
cf
10 Pages
-
TERM
19 Pages
-
TROPIC
3 Pages
-
UGCH
3 Pages
-
UGW/D
6 Pages
-
BRAVA
3 Pages
-
ROTON
3 Pages
-
UWKIII
4 Pages
-
DAWGnw
10 Pages
-
DAWGo
10 Pages
-
Fans control and automatics
13 Pages
-
WD PLUS
4 Pages
-
RGS
19 Pages
-
CHW
3 Pages