ВЕНТИЛЯЦИОННЫЕ УСТАНОВКИ ROOF SUPPLY AND EXHAUST UNIT WITH HEAT RECOVERY КРЫШНАЯ ПРИТОЧНО-ВЫТЯЖНАЯ УСТАНОВКА С РЕКУПЕРАЦИЕЙ INTRODUCTION DAWGo ventilation and heating roof units in supply and exhaust version with heat recovery on cross-flow heat exchanger are intended for heating and ventilation of large commercial premises, warehouses, production halls, sports halls and other objects located in single-storey buildings or on the highest storeys of other buildings. The air supply from above towards the floor, vertically or at a certain angle, limits the adverse temperature stratification inside the hall and reduces heat losses through the ceiling keeping the strictly set temperature within the operation zone at the same time. Air is supplied draught-freely and evenly by a swirl diffuser set remotely from the control box. DAWGo units constitute constructional development of DAWGN/W units through introduction of cross-flow plate exchanger for heat recovery to them. The unit consists of a roof section, mounted on the roof plinth, and vertical supply and exhaust section, suspended to it and located below the roof. The unit includes below-mentioned functional components: Установка состоит из верхнего блока, который устанавливается на крыше (на заранее подготовленном фундаменте), и подвешенного к нему вертикального нижнего блока, находящегося под крышей. В состав установки входят: Крышные приточно-вытяжные установки с рекуперацией тепла DAWGo предназначены для обработки воздуха в больших торговых, промышленных, спортивных и других помещениях, размещенных в одноэтажных зданиях или на последнем этаже многоэтажного здания. Подача воздуха в помещение осуществляется сверху вниз, вертикально или под определенным углом, что ограничивает некомфортное температурное расслоение внутри помещения, снижает теплопотери через перекрытие и поддерживает в рабочей зоне строго заданную температуру. Равномерный приток воздуха без сквозняков осуществляется при помощи вихревого воздухораспределителя, управляемого дистанционно со щита управления. Установки DAWGo являются конструктивной разновидностью установок DAWGn/w, в их конструкцию добавлен пластинчатый рекуператор. 1. Roof / Крыша 2. Air exhaust cowl/ Козырек 3. Exhaust fan / Вытяжной вентилятор 4. Casing / Корпус 5. Recirculating air damper / Заслонка рециркуляции 6. Supply fan/ Приточный вентилятор 7. External air by-pass air damper / Заслонка байпаса наружного воздуха 8. Base / Основание 9. Air intake cowl / Козырек 10. G4 class external air filter / Фильтр наружного воздуха класса G4 11. External air damper interlocked with pos.7 air damper / Заслонка наружного воздуха, соединенная с заслонкой п. 7 12. Cross-flow heat exchanger / Пластинчатый рекуператор 13. Droplet eliminator / Каплеуловитель 14. Removed air filter / Фильтр на вытяжке 15. Supply air chamber / Камера приточного воздуха 16. Removed air inlet / Вход удаляемого воздуха 17. Dual-function water heat exchanger / Водяной теплообменник (нагреватель/охладитель) 18. Droplet eliminator - option with cooling coil / Каплеуловитель - при варианте с воздухоохладителем 19. Swirl diffuser / Вихревой воздухораспределитель 20. Separation chamber – option with assembly of two diffusers / Камера раздела воздуха - при варианте с двумя воздухораспределителями 21. Air inlet droplet eliminator / Каплеуловитель на входе воздуха 22. External air inlet air damper / Заслонка на входе наружного воздуха 23. Removed air outlet air damper / Заслонка на выходе вытяжного воздуха
Open the catalog to page 1ВЕНТИЛЯЦИОННЫЕ УСТАНОВКИ ОПИСАНИЕ КОНСТРУКЦИИ ROOF SECTION CASING The construction of the casing (4) is based on the framework, made of aluminium profiles, and sandwich type panels, made of galvanised sheet metal. The panels are filled with 45mm thick mineral wool. The upper part of the unit has the roof (1), made of galvanised sheet metal, in order to protect it against atmospheric precipitation. The air fresh inlet is equipped with the inclined air intake (9). The outlet of removed air is equipped with air exhausts (2). The technical data for the casing according to the standard PN-EN...
Open the catalog to page 2ВЕНТИЛЯЦИОННЫЕ УСТАНОВКИ OPERATION MODES 100% OF FRESH AIR 100% СВЕЖЕГО ВОЗДУХА РЕЖИМЫ РАБОТЫ PARTIAL RECIRCULATION ЧАСТИЧНАЯ РЕЦИРКУЛЯЦИЯ TECHNICAL DATA FANS PARAMETERS Size Типоразмер Min. air flow [m3/h] Минимальный расход воздуха, м3/ч Max. air flow [m3/h] Максимальный расход воздуха, м3/ч Nominal voltage[V] Номинальное напряжение, В Frequency [Hz] Частота, Гц Nominal power [kW] Номинальная мощность, кВт Nominal current consumption [A] Номинальное потребление тока, А Protection level Степень защиты ТЕХНИЧЕСКИЕ ДАННЫЕ ПАРАМЕТРЫ ВЕНТИЛЯТОРОВ DAWGo-1
Open the catalog to page 3ВЕНТИЛЯЦИОННЫЕ УСТАНОВКИ Unit size Типоразмер установки Heat exchanger designation Обозначение теплообменника DN [mm] DN, мм Heat exchanger capacity [dm3] Емкость теплообменника, дм3 HEATING FUNCTION / ФУНКЦИЯ ОБОГРЕВА Water parameters [OC] Параметры воды OC Air inlet temperature [OC] Температура воздуха на входе OC 32 28 Water parameters [OC] Параметры воды OC Designations for thermal calculation table: T1 - air inlet temperature [OC]; Tn - air outlet temperaturte [OC]; Q - heat exchanger output for specified parameters [kW]; Mw - mass flow of heating medium [kg/s]; Pw - hydraulic...
Open the catalog to page 4AIR HANDLING UNITS AIR THROW ВЕНТИЛЯЦИОННЫЕ УСТАНОВКИ ДАЛЬНОСТЬ СТРУИ ВОЗДУХА Air throw L [m] Дальность струи L, м DIFFUSER TYPE N1 / ВОЗДУХОРАСПРЕДЕЛИТЕЛЬ N1 Air flow [m3/h] / Расход воздуха, м3/ч Air throw L [m] Дальность струи L, м DIFFUSER TYPE N2/ ВОЗДУХОРАСПРЕДЕЛИТЕЛЬ N2 Air flow [m3/h] / Расход воздуха, м3/ч Air throw L [m] Дальность струи L, м DIFFUSER TYPE N3/ ВОЗДУХОРАСПРЕДЕЛИТЕЛЬ N3 Air flow [m3/h] / Расход воздуха, м3/ч Air throw L [m] Дальность струи L, м DIFFUSER TYPE N4/ ВОЗДУХОРАСПРЕДЕЛИТЕЛЬ N4 Air flow [m3/h] / Расход воздуха, м3/ч
Open the catalog to page 5ВЕНТИЛЯЦИОННЫЕ УСТАНОВКИ ГАБАРИТНЫЕ РАЗМЕРЫ И МАССЫ NOTE! The total height (H1) of the ceiling mounted part depends on the height of (E) mixing chamber and droplet eliminator section, which is mounted, if the heat exchanger is used as the cooling coil. ВНИМАНИЕ! Общая высота (Н1) нижнего блока установки зависит от высоты (Е) смесительной камеры, а также секции каплеуловителя, которая монтируется в случае применения теплообменника в качестве охладителя. DIMENSIONS [mm] / ГАБАРИТНЫЕ РАЗМЕРЫ, мм DAWGo-1 Upper part / Верхний блок Recirculation chamber 1000mm / Камера смешения 1000 мм...
Open the catalog to page 6All JUWENT - SZYMANSKI - NOWAKOWSKI - JANIK SP. J. catalogs and technical brochures
-
floor convectors
40 Pages
-
HEAT EXCHANGERS
6 Pages
-
Product overview
9 Pages
-
rgs
12 Pages
-
wko
4 Pages
-
wkp
12 Pages
-
cf
10 Pages
-
TERM
19 Pages
-
TROPIC
3 Pages
-
UGCH
3 Pages
-
UGW/D
6 Pages
-
BRAVA
3 Pages
-
ROTON
3 Pages
-
UWKIII
4 Pages
-
DAWGnw
10 Pages
-
Fans control and automatics
13 Pages
-
WD PLUS
4 Pages
-
RGS
19 Pages
-
CHW
3 Pages