System INDUSTRY

System INDUSTRY

System INDUSTRY

Product catalog summary
Overview
JUPITER Heating System Ltd offers the System INDUSTRY, a robust underfloor heating solution designed for industrial applications. This system is ideal for large, open-plan buildings, providing efficient heating by radiating warmth from the floor upwards, which can result in energy savings of up to 30% compared to traditional systems.
Advantages
  • Reduced energy costs and maintenance-free operation.
  • Space-saving design with lower initial capital outlay.
  • Meets minimum floor temperature requirements of 18°C.
  • Utilizes lower temperature water supply, suitable for heat pumps.
  • No dust creation due to lack of major warm air circulation.
Temperature Profile
The system provides a more efficient temperature profile compared to traditional high-level warm air systems, avoiding the congregation of warm air near the ceiling.
Installation Options
  • Concrete slab with lower and upper steel mesh reinforcement.
  • Pre-stressed concrete with mesh reinforcement.
  • Steel fibre concrete without mesh reinforcement.
  • Vacuum concrete with specific processes.
Insulation beneath the slab should have high compressive strength and moisture resistance, such as XPS or Foamglass.
Pipe Specifications
The system uses a 20 x 2.25mm multi-layer PERT aluminium core pipe. Pipe layout is typically fixed to the lower steel reinforcement mesh to avoid interference with machinery or storage systems.
Construction Variations
  • B1: With insulation, double mesh reinforcement.
  • B2: Without insulation, double mesh reinforcement.
  • B3: Without insulation, single mesh reinforcement.
Load Capacities and Applications
Slab ThicknessMesh TypeApplicationMax Static LoadMax Moving Load
150mmQ131 Single layerWorkshops, vehicle showrooms (cars)30 kN/1.5t12 kN/1.2t
150mmQ131 Double layerWorkshops, vehicle showrooms (up to 7.5t)50 kN/5.0t16 kN/1.6t
180mmQ131 Double layerWarehouses with forklifts & trucks (up to 5t)70 kN/7.0t50 kN/5.0t
200mmQ188 Double layerMachinery factory with rolling traffic (<=7.5t)100 kN/10.0t70 kN/7.0t
250mmQ131High-level shelving storage, large trucks150 kN/15.0t100 kN/10.0t
Technical Specifications
  • Minimum construction height: 150mm with 2 x Q131 mesh.
  • Pipe distances: 15-45 cm, with maximum pipe length of 110 mm.
  • Typical performance: 80W/m² with a flow temperature of 45-50°C.
See more

Catalog excerpts

System INDUSTRY-1

Application System INDUSTRY Application System INDUSTRY is the heavy duty underfloor heating solution from JUPITER suitable for a wide range of industrial applications. As is commonly known, underfloor heating radiates heat from the floor up and is perfect for use in large, open plan buildings by keeping the immediate area warm where the workforce operate. Savings with underfloor heating can be up to 30% over traditional high level warm air systems, not only by using less energy but by dramatically reducing maintenance costs. Temperature profile The difference in temperature profile between an underfloor heating system and traditional high level warm air system is clear to see. The congregation of warm air just below the ceiling is demonstrated in this diagram. The advantages Reduced energy costs Space saving Lower initial capital outlay Meets minimum floor temperature requirements (18° ) Ideal temperature profile Lower temperature water supply (i.e. heat pump) Completely maintenance free No dust created – no major warm air circulation Installation JUPITER System INDUSTRY is integrated within the concrete floor slab. The various options are: ● Concrete slab reinforced with lower and upper steel mesh reinforcement ● Pre-stressed concrete with mesh reinforcement ● Steel fibre concrete without mesh reinforcement ● Vacuum concrete (steel, pre-stressed or steel fibre in conjunction with specific vacuum process) If insulation is to be incorporated beneath the slab, a product with high compressive strength and moisture resistance should be used. i.e. XPS or Foamglass Typically the mesh reinforcement is used to fix the underfloor heating pipe work. Using 3 cable ties per linear metre the pipe is fixed to the lower of the two steel meshes. Pipe work within slabs without steel reinforcing mesh can be fixed down using traditional pipe clip rail. Pipe dimension JUPITER System INDUSTRY is based on the proven 20 x 2.25mm multi layer pipe PERT aluminium core pipe. JUPITER Heating System Ltd Chobham Surrey GU24 8DJ T +44 (0) 1276 859 066 F +44 (0) 1276 856 894 www.jupiterunderfloorheating.com

 Open the catalog to page 1
System INDUSTRY-2

As a rule the pipe layout is fixed to the lower steel reinforcement mesh, so that the drilling depth (for the fixing of machinery or storage systems) does not come in contact with the pipe work. Slab Thickness Distance: Upper mesh to top of slab Mesh Type Application Max. static Load /m² Max. moving load with = axle load 150mm Q131 Single layer 80 mm Workshops and vehicle showrooms (limited to cars) 30 kN/1,5t 12 kN/1,2t 150mm Q131 Double layer 80 mm Workshops and vehicle showrooms (limited to 7.5t) 50 kN/5,0t 16 kN/1,6t 180mm Q131 Double layer 110 mm Warehouses with Fork lifts & trucks to 5t...

 Open the catalog to page 2

All Jupiter Underfloor Heating catalogs and technical brochures

Archived catalogs

  1. IDEAL

    2  Pages

  2. IDEAL ECO

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.