WALL TRAYS Steel Wall Trays MR137 / 30 Sept 2025
Open the catalog to page 1Joris Ide NV. is not responsible for printing errors and / or any differences between the images in this catalogue and the final product delivered. Joris Ide NV reserves the right to modify the technical specifications at any time without prior notice. To ensure that you have the latest version at hand, we invite you to scan this QR code to retrieve the latest version on our website www.joriside.com.
Open the catalog to page 2WALL TRAYS Steel Wall Trays - Realisation with wall trays for an industrial project. The foundation of double-skin façades With more than 40 years of experience in metal profiling, Joris Ide offers one of the most comprehensive ranges of steel wall trays on the market. Manufactured in galvanized and pre-coated steel, our trays form the inner component of double-skin façade systems, designed Visible wall trays, during construction of a wall cladding. to combine structural strength with thermal and acoustic performance. Engineered for horizontal installation, our wall trays distribute loads evenly...
Open the catalog to page 3Wall Trays The JID 110-600 is a steel inner liner for double-walled facades. This inner liner structure is installed horizontally. Attach it to the ribs on the inside and fill it with thermal insulation, thus ensuring firm support for the outer sheet. The use of spacers is also possible. This inner liner is available in different sizes and versions (on request). The steel inner liner can be coated on the A-side with an interior coating. Thickness 1,25 mm and 1,50 mm only upon request. | Technical characteristics Standard length Effective width Type of metal Coatings Accessories Galvanized steel...
Open the catalog to page 4Design method according to EN 1993-1-3. The permissible loads depend on the number of supports and the (unweighted) loads calculated according to Eurocode. The considered deflection limit is L/150. Please consult the Technical Department if you have any questions. The above load is the total load in Ultimate Limit State (UGT) divided by 1,5.
Open the catalog to page 5Wall Trays The JID 130-600 is a steel liner tray designed for double-skin fagades. Installed horizontally, it ensures strong structural support for external cladding while efficiently accommodating thermal insulation within the tray. The design is compatible with spacers to optimize thermal performance. Available in various sizes and configurations upon request, the JID 130-600 offers long-term resistance and adaptability for a wide range of construction projects. Thickness 1,25 mm and 1,50 mm only upon request. | Technical characteristics Standard length Effective width Type of metal Coatings...
Open the catalog to page 6Design method according to EN 1993-1-3. The permissible loads depend on the number of supports and the (unweighted) loads calculated according to Eurocode. The considered deflection limit is L/150. Please consult the Technical Department if you have any questions. The above load is the total load in Ultimate Limit State (UGT) divided by 1,5.
Open the catalog to page 7Wall Trays The JID 145-600 is a steel inner liner tray designed for robust double-skin fagades. Installed horizontally, it provides exceptional structural support for external cladding while efficiently accommodating thermal insulation within the tray. Its design allows for the integration of spacers to further enhance thermal performance. Available in various sizes and configurations upon request, the JID 145-600 ensures long-term resistance and adaptability for a wide range of construction projects. Thickness 1,25 mm and 1,50 mm only upon request. | Technical characteristics Standard length...
Open the catalog to page 8Design method according to EN 1993-1-3. The permissible loads depend on the number of supports and the (unweighted) loads calculated according to Eurocode. The considered deflection limit is L/150. Please consult the Technical Department if you have any questions. The above load is the total load in Ultimate Limit State (UGT) divided by 1,5.
Open the catalog to page 9Wall Trays The JID 160-600 is a steel liner tray designed for double-skin facades, ensuring structural reinforcement and insulation integration. With a U-shaped profile, it provides a secure foundation for external cladding while allowing thermal insulation to be inserted into the system. Installed horizontally, it ensures load distribution and installation efficiency. The JID 160-600 is compatible with spacers, offering flexibility for various construction requirements. Available in custom dimensions and finishes, it is a versatile choice for industrial and commercial applications. Thickness...
Open the catalog to page 10Design method according to EN 1993-1-3. The permissible loads depend on the number of supports and the (unweighted) loads calculated according to Eurocode. The considered deflection limit is L/150. Please consult the Technical Department if you have any questions. The above load is the total load in Ultimate Limit State (UGT) divided by 1,5.
Open the catalog to page 11With more than 40 years of experience, Joris Ide represents a guarantee of quality in the construction market. We bring solutions to all your problems: acoustic, aesthetic, fire, thermal. Joris Ide, the essential partner for all your projects.
Open the catalog to page 1240 Pages