STRUCTURAL DECKING
72Pages

{{requestButtons}}

Catalog excerpts

STRUCTURAL DECKING - 1

STRUCTURAL DECKING Designer’s guide MR024 / 0921

Open the catalog to page 1
STRUCTURAL DECKING - 2

Membrane Roof System_________________ 4 Standing Seam System__________________ 4 Green Roofs_________________________________ 4 Perforation patterns______________________ 5 JID 50-250-1000 Perfo Flange___ 37 JID 50-250-1000 Perfo Web______ 38 JID 85-280-1120______________________ 39 JID 85-280-1120 Perfo Web_______ 40 JID 89-305-915_______________________ 41 JID 106-250-750_____________________ 45 JI 35-207-1035 R______________________ 10 JI 35-207-1035 R Perfo Flange_____ 11 JI 37-265-1060_________________________12 JI 42-252-1010_________________________13 JI 42-252-1010 Perfo...

Open the catalog to page 2
STRUCTURAL DECKING - 3

STRUCTURAL DECKING Designer’s guide Steeldeck production at our plant in Zwevezele, Belgium. The Joris Ide Group is one of the largest independent European producers of insulated and non-insulated cladding systems and components. Its product range varies from single skin profiles to continuous produced PIR and Rockwool composite panels, purlins, flashings, rainscreen cladding and structural metal decking. Perforated decks for acoustic purposes. Metal decking is used in commercial and industrial applications for a built-up flat or low pitched roof. In combination with site-applied insulation...

Open the catalog to page 3
STRUCTURAL DECKING - 4

JI decks Production site Zwevezele, Belgium Materials The decks are available in the following materials: Galvanized steel 15 µ Polyester R912 steel 25 µ Polyester standard colour Prepainted aluminium Colorcoat HPS 200 Ultra® (prefinished steel

Open the catalog to page 4
STRUCTURAL DECKING - 5

JID decks Production site Ansbach, Germany

Open the catalog to page 5
STRUCTURAL DECKING - 6

Membrane Roof System Membrane Roof Systems with structural decks are often used for very low pitched or flat roofs combining long spans. The classic built-up exists out of JI Structural Deck in steel or aluminium with the option for perforation to improve acoustic absorption. Essential for this warm roof construction a vapour barrier is applied between the PIR, mineral wool or glass fibre insulation to be finished with a waterproof membrane . Standing Seam System Standing Seam Systems are used for the combination of their secret fixation, ability for low pitched roofs and curved roofs. The...

Open the catalog to page 6
STRUCTURAL DECKING - 7

Perforation patterns Perforation in the decks are available depending on the type of deck and the location of the perforation (web, pan or full) to improve the acoustic absorption performance of the built-up system. Each Joris Ide decking production site has a high-performance perforating line to offer what is required for the project. Joris Ide Belgium offers the following perforation patterns: 6 Joris Ide Deutschland offers the following perforation patterns: 8

Open the catalog to page 7
STRUCTURAL DECKING - 8

Mounting instructions Storage and handling The packs need to be unloaded at site in a controlled and careful way not to damage the goods and according to the health and safety regulations at force. Once unloaded, the packs need to be safely stored inside a cool and dry building and under a small slope in order to have no storage stain (white rust). Fixing recommendations The table below gives an overview of the recommended fixations. These recommendations are based upon good practice and do not take away the responsibility of the designer and the installer to check the limits of the...

Open the catalog to page 8
STRUCTURAL DECKING - 9

Diaphragm What is a diaphragm action? The roof sheeting in a rectangular building under horizontal loads behaves like the web of a deep plate girder spanning between vertical planes of support. In this plate girder the longitudinal edge members behave as flanges, carrying the axial tension and compression. The girder helps resist horizontal loads. In a pitched roof building the roof slopes help to resist both horizontal and vertical loads. Shear field in sheeting Flange forces in edge members Sheeting Roof sheeting acts as a deep plate girder carrying load back to stiffened gables A shear...

Open the catalog to page 9
STRUCTURAL DECKING - 10

Extended end laps When decks of long length impact the cost of transportation or create an inefficiency for handling or installing on-site, the solution of extended overlaps can be applied. Extended overlaps between two single span decks create a double span condition which enhances the mechanical performance. Therefore the below conditions need to be respected: Extended overlaps can only be used for decks manufactured out of steel. For perforated variances and aluminium decks please consult the Joris Ide Technical Support Team. The end lap must extend by 10% of the span from the opposite...

Open the catalog to page 10
STRUCTURAL DECKING - 11

Designer’s guide to structural decking Production site: Joris Ide Zwevezele, Belgium

Open the catalog to page 11
STRUCTURAL DECKING - 12

Structural metal roof deck Interior liner and Galvanised Intermediate Support width: Mechanical Properties Broad flange in compression tN [mm] Mc,Rk,F [kNm/m] Mc,Rk,B [kNm/m] Narrow flange in compression Mc,Rk,F [kNm/m] Mc,Rk,B [kNm/m] Load type (kN/m²) Span (m) pressure load - deflection limit L/200 suction load - deflection limit L/150 the load shown is the ultimate load divided by 1,5 APPLIED STANDARDS / NOTES Tolerances/Coatings Tests/Calculations EN 10143 Steel Quality EN 10346 Handling European Recommendations EN 1990, EN 1991 1-6, EN 1993 1-3, EN 1993 1-5 (Calculations are to...

Open the catalog to page 12
STRUCTURAL DECKING - 13

Structural metal roof deck Interior liner and Galvanised Intermediate Support width: Mechanical Properties Broad flange in compression tN [mm] Mc,Rk,F [kNm/m] Narrow flange in compression Mc,Rk,B [kNm/m] Mc,Rk,F [kNm/m] Mc,Rk,B [kNm/m] Load type (kN/m²) Span (m) Single Pressure pressure load - deflection limit L/200 suction load - deflection limit L/150 the load shown is the ultimate load divided by 1,5 APPLIED STANDARDS / NOTES Tolerances/Coatings Tests/Calculations EN 10143 Steel Quality EN 10346 Handling European Recommendations EN 1990, EN 1991 1-6, EN 1993 1-3, EN 1993 1-5...

Open the catalog to page 13
STRUCTURAL DECKING - 14

Structural metal roof deck Interior liner and Galvanised Intermediate Support width: Mechanical Properties Broad flange in compression tN [mm] Mc,Rk,F [kNm/m] Mc,Rk,B [kNm/m] Narrow flange in compression Mc,Rk,F [kNm/m] Mc,Rk,B [kNm/m] Load type (kN/m²) Span (m) Single Pressure pressure load - deflection limit L/200 suction load - deflection limit L/150 the load shown is the ultimate load divided by 1,5 APPLIED STANDARDS / NOTES Tolerances/Coatings Tests/Calculations EN 10143 Steel Quality EN 10346 Handling European Recommendations EN 1990, EN 1991 1-6, EN 1993 1-3, EN 1993 1-5...

Open the catalog to page 14

All Joris Ide catalogs and technical brochures

  1. Projects!