Catalog excerpts
) We must remind you that the reductions in bacteria-moulds-VOC-viruses may vary from those indicated based on the characteristics of the environment and its use (size, presence density, ventilation, basic hygienic conditions). The virucidal activity was tested using the SARS - CoV-2 (Covid-19) strain. All experiments were conducted in a Biosafety Level 3 Laboratory (BSL3). The use of Jonix devices DOES NOT exclude compliance with the provisions for the prevention and containment of the pandemic. JONIX duct NON THERMAL PLASMA TECHNOLOGY DEVICE FOR SANITIZATION AND DECONTAMINATION OF AERAULIC DUCTS Tested against Covid-19 by the University of Padua Bacteria, Moulds, VOCs and Viruses virus multidrug-resistant bacteria JONIX Inside Technology
Open the catalog to page 1multiresistant bacteria SANITITAZION AND DECONTAMINATION OF AERAULIC DUCTS Bacterial and chemical pollutants develop inside air distribution systems and are transported by the airflow to the rooms. JONIX duct with cold plasma technology eliminates bacteria, viruses, moulds, chemical pollutants, VOC and odours ensuring bacterial decontamination of the ducts’ internal surfaces as well as of the air that flows through. The devices are easy to install thanks to the connections supplied as standard. There are four different models, that is four versions of increasing power level, which can be...
Open the catalog to page 2The most significant features of JONIX duct are: • High efficiency: reduction of bioburden and of volatile organic compounds up to 99% compared to the initial concentration; • Low power consumption: from 10 to 40 VA; • Strong deodorizing action: it eliminates odours from the air flowing through; • Natural process: it does not use nor produces residual chemical substances. Application example of a JONIX duct module on ventilation pipes. JONIX duct JONIX duct is a cold plasma technology device for sanitizing, decontaminating and purifying the internal surfaces of the distribution pipes and...
Open the catalog to page 3multiresistant bacteria EFFICIENCY The bio acid activity occurs for the oxidation process of the membrane cell. Reactive particles carrying electric charges, among which the most important ones are the oxygen reactive species (for example atomic oxygen and ozone), which concentrate on the membrane surface causing its destruction. The device is efficient on: gram + and – bacteria, yeast and mould, virus, bacterial endotoxines, VOC (volatile organic compound), odours. On new pipelines, non-thermal plasma (NTP) prevents the formation of bacterial colonies on the internal surfaces as well as...
Open the catalog to page 4ECOLOGICAL PLANNING Ecological=no chemical products JONIX duct uses no chemical products and produces no residual substances. It can be used without interruptions, even when people are present, or activities are in progress. Its continuous activity, besides purifying the air, generates a correct air ionization that ensures an environmental comfort for the reduction of stress from work, it encourages proper breathing. In order to protect and promote health in working environments. EASY TO INSTALL IN ANY DUCTWORK AND WITH ANY MATERIAL JONIX duct devices – thanks to their adaptability and to...
Open the catalog to page 5multiresistant bacteria TECHNICAL FEATURES duct 2C Modular and easy to install. Designed to fit all existing plants and in the construction phase. The different models can be assembled to form a unit consisting of one version only; it is also possible to create a unit consisting of a combination of different versions to match the volume of the air to be treated. Code Plasma generators DimensionS Weight Type of power supply Consumption Channel air flow rate Colour MADE IN ITALY Designed and created by expert technicians specialized on air purification.
Open the catalog to page 6Hallmark for health and living comfort in confined spaces (UNI EN 16000- UNI EN14 412). Validated product Reference standards NATIONAL LAWS AND STANDARDS Valid for the following categories: Civil, Industrial, and Healthcare sectors Italian Legislative Decree 81/2008 Consolidated Law on Health and Safety in the Workplace of 10th April 2008 (published in the Ordinary Supplement No. 108 of the Offical Gazette No. 101 of 30th April 20081; Legislative Decree No. 81 was published on 9th April 2008) • Guidelines issued by the Italian Presidency of the Council of Ministers (Permanent Conference for...
Open the catalog to page 7multiresistant bacteria Benefit Corporation info@jonixair.com jonixsrl@legalmail.it Registered Office Viale Spagna 31/33 35020 Tribano (PD) - Italy Ph. +39 049 9588511 Fax +39 049 9588522 Operational Headquarters Via dell’Artigianato, 1 35020 San Pietro Viminario (PD) – Italy Ph. +39 0429 760311 Research and Development Headquarters Via Tegulaia 10/b 56121 Pisa - Italy Ph. +39 050 98516
Open the catalog to page 8All Jonix S.p.A Società Benefit catalogs and technical brochures
-
JONIX vmc 4people LINE
8 Pages
-
JONIX micromate LINE
8 Pages
-
JONIX minimate LINE
8 Pages