Catalog excerpts
Johns Manville Formaldehyde-free™ Fiber Glass Insulation JM FORMALDEHYDE-FREE" FIBER GLASS INSULATION Sensitive to growing concerns about indoor air quality and the need for environmentally responsible building products, Johns Manville has revolutionized the building insulation industry by introducing the only complete line of fiber glass insulation made without formaldehyde. Why is that important? Because the U.S. Environmental Protection Agency (EPA) recommends limiting exposure to formaldehyde as much as possible, and the California Air Resources Board, a division of the California EPA, recommends that homeowners, builders and architects use building materials and insulation made without formaldehyde when building a home or remodeling JM Formaldehyde-free™ insulation will not off-gas formaldehyde in the indoor environment, so it improves indoor air quality while delivering superior thermal and acoustical performance. In addition, because we've removed the formaldehyde, we've eliminated binder-related formaldehyde emissions during manufacturing; as a result, JM Formaldehyde-free™ fiber glass insulation plants are the only ones exempt from U.S. EPA Hazardous Air Pollutant regulations. Visit us at specJM.com for more information PROTECTED FROM MOLD AND MILDEW Johns Manville MR® Faced insulation resists the growth of mold and mildew. We have treated the facing with an EPA-registered mold inhibitor to help protect it from the potential growth of fungi. The facing passes the stringent ASTM D2020 fungi test for paper and paperboard, and both the fiber glass insulation and the facing pass the ASTM C1338 fungi test (molds and mildew are types of fungi) PRODUCT DESCRIPTION JM's MR® Faced insulation is a lightweight thermal and acoustical fiber glass insulation made of long, resilient glass fibers bonded with an acrylic thermosetting binder. The facing is protected against mold growth and serves as a "smart" vapor retarder; in extreme humidity, the permeability doubles and allows moisture to escape at a faster rate AVAILABLE FORMS Pre-cut batts fit standard wall cavities and are faster to install than rolls. MR® Faced batts are available in a variety of R-values, widths and lengths; contact your JM sales representative for more information • Wood-frame construction - residential homes and light commercial buildings • Metal-frame construction - commercial buildings • Pre-manufactured homes - modular or manufactured housing • Interior wall sound control - interior walls and floor and ceiling assemblies (for sound class ratings for wall assemblies, see the appropriate STC values data sheet for either steel or wood framing) Visit JM.com or check with your JM sales representative for available sizes MR® Faced insulation batts are easy to cut with an ordinary utility knife. You can install the batts by attaching the stapling tabs to wood framing, use fasteners or simply press into place between studs or joists. The facing will burn and must not be left exposed. It must be covered with gypsum board or another approved interior finish. For exposed applications, use FSK-25 flame-resistant faced insulation Note: In colder climates, the vapor retarder (whether attached to the insulation or applied separately) is usually placed toward the heated or conditioned side of the wall to reduce water vapor penetration into the wall from the building interior. Conversely, in predominately hot, humid climates, codes often dictate that you place the vapor retarder toward the outside of the wall cavity. Check your local building code for vapor retarder requirements SPECIFICATION COMPLIANCE ASTM C 665, Type II, Class C, Category 1 ASTM E 96 Permeability; Kraft 1 Perm ASTM D 2020,* Fungus resistant JM Formaldehyde-free™ Thermal, Acoustical, Mold- and Mildew-resistant Fiber Glass Insulation PERFORMANCE ADVANTAGES: • Made without formaldehyde - will not off-gas formaldehyde in the indoor environment. • Thermally efficient - provides effective resistance to heat transfer with R-values • Mold-resistant - fiber glass and facing resist the growth of fungi. • Controls moisture - resists water vapor transmission. • Controls sound - reduces transmission of conversations and equipment noises through interior and exterior walls and floor and ceiling assemblies. • Noncorrosive - does not accelerate corrosion of pipes, wiring or metal studs • Durable - unaffected by moisture, oil, grease and most acids. It will not rot, mildew or otherwise deteriorate. • Resilient - bonded glass fibers will not pull apart during normal applications and resist settling, breakdown and sagging from vibration. • Flexible - forms readily around corners and curved surfaces. *Facing test method standardized for asphalt-coated Kraft
Open the catalog to page 1JM Formaldehyde-free™ Thermal, Acoustical, Mold- and Mildew-resistant Fiber Glass Insulation Visit our website at specJM.com BUILDING CODE COMPLIANCE AND FIRE HAZARD CLASSIFICATION ICBO SBCCI BOCA IBC/IRC Flame Spread* Smoke Developed* MR* Faced Types III, IV, V Types III, V, VI Types III, IV, V Types III, IV, V/AII Types Not Rated Not Rated This insulation is compression-packaged for savings in storage and freight costs RECOMMENDED STORAGE AND TRANSPORT Store insulation indoors. Keep insulation clean and dry at all times. When transporting, cover completely with a waterproof tarpaulin as...
Open the catalog to page 2All Johns Manville catalogs and technical brochures
-
Kraft-Faced
2 Pages
-
ComfortTherm®
2 Pages
-
EasyFit ®
2 Pages
-
Unfaced
2 Pages
-
Attic Protector ®
2 Pages
-
Climate Pro®
2 Pages
-
JM Spider®
2 Pages