1. Catalogs
  2. JELD-WEN
  3. stairs layout
video corpo

stairs layout

stairs layout
1 / 12 PagesView full catalog

stairs layout

Product catalog summary
Overview: This document outlines technical specifications and layout details for stair designs, focusing on dimensions and headroom requirements. It includes multiple layouts labeled P, Q, R, S, and T, each with specific measurements and considerations.
Specifications:
  • Dimension A: Refers to various measurements such as wall string to wall string, pulpit end string to back of top riser, or back of top riser to back of top riser, depending on the layout.
  • Dimension B: Typically measures the face of the bottom riser to the back of the wall string.
  • Dimension H: Indicates the minimum distance required for statutory headroom, based on storey heights between 2588mm and 2680mm with a 339mm floor zone.
  • Width Overall Strings: Consistently noted as 905mm across layouts.
  • Unobstructed Width: Varies, with examples including 860mm and 815mm, not accounting for wall handrails.
Procedures and Recommendations:
  • Ensure headroom complies with statutory requirements based on specified storey heights.
  • Consider the projection of wall handrails when calculating unobstructed width.
  • Landing boards and bearers are not included in the dimensions and should be accounted for separately.
Key Data from Tables:
  • Various numerical sequences appear throughout, possibly indicating part numbers or measurements, but lack context for detailed interpretation.
Conclusion: The document serves as a guide for understanding stair layout dimensions and ensuring compliance with headroom regulations. It emphasizes the importance of considering additional elements like handrails and landing boards in the overall design.
See more

Catalog excerpts

stairs layout-1

TELBrWEN WINDOWS & DOORS

 Open the catalog to page 1
stairs layout-2

Stair Layouts JELD-WEN manufactures all staircases to order in almost any design, size or specification. However, to help plan your flight, our 20 most popular layouts are listed on the following pages together with the critical dimensions relevant to each design including the trimming dimension necessary to obtain headroom clearance. Our specialist stairs team is always on hand to offer help and advice on any aspect of design, construction or Part ‘K’ of the Building Regulations. You can contact them on 01664 484613 or speak to your dedicated stairs technician. Dimension 'B' : Face of bottom...

 Open the catalog to page 2
stairs layout-3

Width overall strings: 905 Note: Landing boards and bearers are not included Minimum trim length: 3454 Dimensions A: Wall string to back of top riser B: Face of bottom riser to back of wall string H: inimum distance to give statutory headroom (Based on storey heights M between 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Trim Length: 2767 Dimension ‘A’: 2733 Width...

 Open the catalog to page 3
stairs layout-4

STAIR LAYOUTS Trim width: 2061 Dimension ‘A’: 2013 19 Note: Landing boards and bearers are not included A: Wall string to wall string B: Face of bottom riser to back of wall string C: Back of top riser to wall string H: inimum distance to give statutory headroom M (Based on storey heights between 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. U nobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Width overall strings:...

 Open the catalog to page 4
stairs layout-5

Minimum trim width: 1965 Dimension ‘A’: 1917 Note: Landing boards and bearers are not included A: Wall string to wall string B: Face of bottom riser to back of wall string C: Back of top riser to wall string H: inimum distance to give statutory headroom M (Based on storey heights between 2588mm up to 2680mm with 339mm floor zone) H eadroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Width overall strings: 905 Width...

 Open the catalog to page 5
stairs layout-6

STAIR LAYOUTS Width overall strings: 905 Width overall strings: 905 Dimensions A: Wall string to back of top riser B: Face of bottom riser to back of wall string H: inimum distance to give statutory headroom (Based on storey heights between M 2588mm up to 2680mm with 339mm floor zone) H eadroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Trim length: 2920 Dimension ‘A’: 2870 Width overall strings: 905 A: Wall string...

 Open the catalog to page 6
stairs layout-7

Trim width: 2004 Dimension ‘A’: 1954 534 A: Wall string to wall string B: Face of bottom riser to back of wall string C: Back of top riser to wall string H: inimum distance to give statutory headroom M (Based on storey heights between 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Width overall strings: 905 Width overall strings: 905 Trim width: 1929 Dimension ‘A’:...

 Open the catalog to page 7
stairs layout-8

STAIR LAYOUTS Trim width: 1833 Dimension ‘A’: 1783 338 A: Wall string to wall string B: Face of bottom riser to back of wall string C: Back of top riser to wall string H: inimum distance to give statutory headroom M (Based on storey heights between 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension based on a ‘pigs ear’ wall handrail with a 50mm projection being incorporated; should a different type be used the difference in projection would need to be taken into account. Width overall strings:...

 Open the catalog to page 8
stairs layout-9

Layout N Trim length: 2894 Dimension ‘A’: 2859 Width overall strings: 905 Width overall strings: 905 Dimensions A: Wall string to back of top riser B: Face of bottom riser to back of wall string H: inimum distance to give statutory headroom (Based on storey heights between M 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Trim length: 1978 Dimension ‘A’: 1943 Dimensions...

 Open the catalog to page 9
stairs layout-10

STAIR LAYOUTS Layout P Trim width: 2086 Dimension ‘A’: 2036 607 A: Wall string to wall string B: Face of bottom riser to back of wall string C: Back of top riser to wall string H: inimum distance to give statutory headroom M (Based on storey heights between 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Width overall strings: 905 Width overall strings: 905 Trim length:...

 Open the catalog to page 10
stairs layout-11

Trim width: 2233 Dimension ‘A’: 2183 403 A: Wall string to wall string Width overall strings: 905 B: Face of bottom riser to back of wall string C: Back of top riser to wall string H: inimum distance to give statutory headroom (Based on storey heights M between 2588mm up to 2680mm with 339mm floor zone) Headroom based on storey heights between 2588mm up to 2680mm with 339mm floor zone. Unobstructed width dimension does not allow for a wall handrail; should this be a requirement the projection of the handrail would need to be deducted. Width overall strings: 905 Trim length: 2842 Dimension ‘A’:...

 Open the catalog to page 11

All JELD-WEN catalogs and technical brochures

  1. RADCLIFFE

    1  Page

  2. LUMINA PANEL

    1  Page

  3. CROFT Panel

    1  Page

  4. CHESTER

    1  Page

  5. Stairs Brochure

    64  Pages

  6. Concept Folder

    31  Pages

  7. Stairs 2013

    60  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.