1. Catalogs
  2. JAGA
  3. Strada Hybrid

Strada Hybrid

Strada Hybrid
1 / 26 PagesView full catalog

Strada Hybrid

Product catalog summary
Technical Information
  • Dimensions: The units come in various heights and lengths, with optional towel rails made of chrome-plated aluminium.
  • Control Systems: There are three main control systems: Jaga ACO, Jaga BMS 0-10V, and Jaga TPT. These systems provide different functionalities for fan speed and temperature control, allowing for manual or automatic adjustments based on water and air temperature.
  • Hydronic Connection: The unit can be connected on either the left or right side, with control options available below or at the top. Remote control functionality is also offered.
Standard Delivery
  • The package includes a Low-H2O heat exchanger, wall brackets, a fixing kit, an air vent, a drain plug, and a fan unit with control and power supply.
  • Note: A condensation monitor is not included and must be integrated into the installation for cooling purposes.
Colours
  • Standard colours are traffic white, sandblast grey, and off-black. Additional colours are available according to the Jaga colour chart, with surcharges depending on unit length.
Technical Specifications
  • Tables provide detailed information on power output, sound pressure levels, power consumption, weight, and water content for various unit heights and types.
  • Power output is measured according to EN 16430, and noise levels are measured according to ISO 3741:2010.
Connection Sets
  • Various connection sets are available for different pipe diameters and materials, including both metal and synthetic options.
  • Flow can be configured for heating or combined heating and cooling, with automatic flow limiters available.
Guidelines and Recommendations
  • Correction factors and guidelines for limiting flow noise are provided, along with pressure drop information for different types.
See more

Catalog excerpts

Strada Hybrid-3

Optional towel rail 5 Which Jaga control system to choose 7 Connection left or right. 8 Controls below Standard) 8 With remote control 8 Most used connection sets 9 Guideline for limiting flow noise 20

 Open the catalog to page 3
Strada Hybrid-5

STANDARD DELIVERY - Low-H2O heat exchanger with wall brackets and fixing kit, air vent 1/8” and drain plug 1/2” - partially assembled casing for a connection on the bottom left or bottom right - cover plate in stainless steel effect for the side panel at the opposite end from the valve - easy to install fan unit with operation, control and 24VDC power supply This heater is not equipped with a condensation monitor. It has to be integrated into the installation (only for cooling). Eco-friendly, scratch-resistant powder coating with high UV-resistance - traffic white RAL 9016 (133), soft touch lightly...

 Open the catalog to page 5
Strada Hybrid-6

CONTROL SYSTEMS TYPE Jaga ACO (D09) POSITION CONTROL PANEL EXTERNAL 0-10 V WATER TEMPERATURE AIR TEMPERATURE CONTROL SENSOR SENSOR Jaga BMS 0-10V control (D03) JAGA ACO (D09) - The fan speed is selected manually in 3 modes via the control panel. - When the water temperature is lower than 24°C and the air is warmer than the water in the heat exchanger, the fans will start. The unit will then cool the area. - When the water temperature is higher than 28°C and the air is colder than the water, the fans will start. The unit will then heat the area. - The unit will automatically switch from heating...

 Open the catalog to page 6
Strada Hybrid-7

STRADA HYBRID WHICH JAGA CONTROL SYSTEM TO CHOOSE Would you like the unit to have room temperature control? Yes, unit with integrated room temperature control Fans will start automatically when the internal control sends warm/cold water through the radiator. No, unit without integrated room temperature control Fans will start automatically when the external control sends warm/ cold water through the radiator STRADA HYBRID STRADA HYBRID Without 0-10V signal: - room thermostat (None-Jaga) - area control with room temperature control - boiler or heat pump control with room temperature control -...

 Open the catalog to page 7
Strada Hybrid-8

STRADA HYBRID HYDRONIC CONNECTION Room temperature control on the unit SET Unit without integrated room temperature control Thermostatic radiator valve for heating, or for heating + cooling Match the casing on the chosen combination of control system / valve set Standard casing Connection left or right with controls above : Complete the radiator code with 30 (left) or 60 (right). ex. STRW 035 050 11 XXX D09 60 Connection left or right with remote control: Complete the radiator code with 00 (closed sides). ex. STRW.035 050 11 XXX D01 00

 Open the catalog to page 8
Strada Hybrid-9

MOST USED CONNECTION SETS To the wall - FLOW ON THE OUTSIDE With Jaga H-valve To the floor - FLOW ON THE OUTSIDE With Gampper Vario DP Dynamic valve With Jaga H-valve With Gampper Vario DP Dynamic valve automatic flow limiter (20 - 340 l/h) automatic flow limiter (20 -340 l/h) fill in sleeve coupling code fill in sleeve coupling code fill in sleeve coupling code fill in sleeve coupling code To the wall - FLOW ON THE INSIDE With Jaga Crossflow valve To the floor - FLOW ON THE INSIDE With Gampper Vario DP Dynamic valve With Jaga Crossflow valve With Gampper Vario DP Dynamic valve fill in sleeve...

 Open the catalog to page 9
Strada Hybrid-10

Type 11 Type 16 Type 21 Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. enter colour code enter control system code

 Open the catalog to page 10
Strada Hybrid-11

Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. CLIMATE DESIGNERS

 Open the catalog to page 11
Strada Hybrid-12

Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. enter colour code enter control system code

 Open the catalog to page 12
Strada Hybrid-13

Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. CLIMATE DESIGNERS

 Open the catalog to page 13
Strada Hybrid-14

HEIGHT 065 Type 11 Type 16 Type 21 Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. enter colour code enter control system code

 Open the catalog to page 14
Strada Hybrid-15

HEIGHT 065 Type 11 Type 16 Type 21 Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. CLIMATE DESIGNERS

 Open the catalog to page 15
Strada Hybrid-16

Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. enter colour code enter control system code

 Open the catalog to page 16
Strada Hybrid-17

PARTS STANDARD DELIVERY: - grille - front panel - cover plates ORDER CODE CSTW 020 050 11 XXX STANDARD DELIVERY: - heat exchanger - wall brackets ORDER CODE HSTW 020 050 11

 Open the catalog to page 17
Strada Hybrid-18

MOUNTING SET FOR BACK BAR (in pairs) ORDER CODE 5521 011 Number of brackets for heat exchanger - from lengths 050 to 120 cm: 2 units - from lengths 140 to 220 cm: 3 units - from lengths 240 to 280 cm: 4 units HEAT EXCHANGER ORDER CODE 5121 020 000 11 I— Type of heat exchanger '- Height STANDARD DELIVERY: - heat exchanger - incl. angled air vent and drain cock I— Type of heat exchanger 1- Length Overview types of heat exchangers EXTENDED AIR VENT W H35 H50 H65 H95 Order code

 Open the catalog to page 18
Strada Hybrid-19

PARTS STANDARD DELIVERY: - control board with microcontroller ORDER CODE D01: Jaga TPT D03: Jaga BMS D09: Jaga ACO Which type of fan unit is suited for a type of heat exchanger? Strada Hybrid Type 10 Strada Hybrid Type 11 Strada Hybrid Type 15 Strada Hybrid Type 16 Strada Hybrid Type 20 Strada Hybrid Type 21 CLIMATE DESIGNERS

 Open the catalog to page 19

All JAGA catalogs and technical brochures

  1. Mini Hybrid

    10  Pages

  2. Vertiga Hybrid

    20  Pages

  3. Stada Hybrid MM

    20  Pages

  4. Clima Canal 19

    32  Pages

  5. Clima Canal 10

    24  Pages

  6. Clima Canal 08

    24  Pages

  7. BRIZA

    208  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.