GUIDELINE FOR LIMITING FLOW NOISE 12 DEW POINT AIR BY AIR TEMPERATURE AND AIR HUMIDITY AT AIR PRESSURE 1013 HPA 16
Open the catalog to page 3STRADA HYBRID MM DIMENSIONS (in mm) Type 11 Thermostat head inside or outside the casing depending on the selected control Standard supply on the left 50 *socket does not fit within the casing with the H 035 STANDARD DELIVERY completely pre-assembled with: - tight designer casing - Low-H2O heat exchanger with valve insert, thermoelectric motor and extended air vent - fan unit with operating panel, control system and 24 VDC power supply - Euroconus connector block to wall or floor This heater is not equipped with a condensation monitor. It has to be integrated into the installation (only for cooling)....
Open the catalog to page 5CONTROL SYSTEMS TYPE POSITION Jaga ACO (D09) © EXTERNAL 0-10 V CONTROL WATER TEMPERATURESENSOR AIR TEMPERATURE SENSOR ✓ ✓ - The fan speed is selected manually in 3 modes via the control panel. - When the water temperature is lower than 24°C and the air is warmer than the water in the heat exchanger, the fans will start. The unit will then cool the area. - When the water temperature is higher than 28°C and the air is colder than the water, the fans will start. The unit will then heat the area. - The unit will automatically switch from heating to cooling and to standby mode. JAGA TPT (D01) - The...
Open the catalog to page 6CONTROL SYSTEMS Would you like the unit to have room temperature control? Yes, unit with integrated room temperature control Fans will start automatically when the internal control sends warm/cold water through the radiator Room temp. No, unit without integrated room temperature control Fans will start automatically when the external control sends warm/ cold water through the radiator. For example: room thermostat, area control, room temperature regulation via home automation, etc. - room thermostat (None-Jaga) - area control with room temperature control - boiler or heat pump control with room...
Open the catalog to page 735/30 45/40 50/45 55/45 Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. enter colour code enter control system code fill in sleeve couplng code only with ACO control: Thermostat head position only with ACO control: enter code thermostatic head only with ACO control: enter code thermostatic head CLIMATE DESIGNERS head I
Open the catalog to page 9Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 ‘Noise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3 / reverberation time 0.5 sec. enter colour code enter control system code fill in sleeve coupling code only with ACO control• Thermostat head position only with ACO control: enter code thermostatic head only with ACO control• enter code thermostatic head
Open the catalog to page 10Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 “Noise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3 / reverberation time 0.5 sec. enter colour code enter control system code enter connection code only with ACO control: Thermostat head position only with ACO control: enter code thermostatic head only with ACO control: enter code thermostatic head CLIMATE DESIGNERS head
Open the catalog to page 11GRILLE STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart Colour Type Length Colour Length FRONT PANEL Colour Length Height Colour Type Height MOUNTING SET FOR BACK BAR (in pairs) ORDER CODE 5521 011 BRACKETS (per unit) Number of brackets for heat exchanger - from lengths 050 to 120...
Open the catalog to page 12HEAT EXCHANGER STANDARD DELIVERY: - heat exchanger Type of heat exchanger Length Overview types of heat exchangers Strada Hybrid MM Type 11 Strada Hybrid MM Type 16 Strada Hybrid MM Type 21 HEIGHT 035 HEIGHT 050 HEIGHT 065 DBH UPGRADE SET STANDARD DELIVERY: - fan unit(s) - control board with microcontroller - AC adapter 230 V/ 24VDC ORDER CODE DBHS 060 10 D01 EU Control: Jaga TPT (D01) DBH Upgrade set Length Which type of fan unit is suited for a type of heat exchanger? Linea Plus Hybrid Type 11 DBH unit 10 Linea Plus Hybrid Type 16 Linea Plus Hybrid Type 21
Open the catalog to page 13CORRECTION FACTORS The indicated outputs at AT 50 are exact values, measured in accordance with EN442. This table provides a calculated value using an average correction factor for all other AT outputs, valid for all dimensions. Click www.jaga.com/selection-tools/to download the calculation tools with the exact outputs. The online calculation tools are kept up to date with the most recent data. Minor output differences between printed tables and the different online calculation tools are therefore completely normal and within the margins of tolerance imposed by the standard. AVERAGE CORRECTION...
Open the catalog to page 14PRESSURE DROP TYPE 11 AP
Open the catalog to page 15PRESSURE DROP TYPE 16 AP
Open the catalog to page 16PRESSURE DROP TYPE 21 AP
Open the catalog to page 17STRADA HYBRID MM DAUWPUNT LUCHT I.F.V. LUCHTTEMPERATUUR EN LUCHTVOCHTIGHEID BIJ LUCHTDRUK 1013 HPA ONDERGRENS WATERTEMPERATUUR "LIGHT COOLING" Wanneer een toestel niet voorzien is van een aangesloten condensafvoer, dan moet er voorkomen worden dat er condens op de warmtewisselaar in het toestel ontstaat. Dit is sowieso van toepassing op Jaga toestellen "light cooling". Om condensvorming te voorkomen moet de watertemperatuur hoger zijn dan het dauwpunt van de lucht waarin het toestel opereert. In deze tabel is de minimale watertemperatuur weergegeven waarboven een toestel kan werken om condens...
Open the catalog to page 18CLIMATE DESIGNERS
Open the catalog to page 19In need of some advice? Make an appointment at the Jaga Advice Centre. Verbindingslaan 16 3590 Diepenbeek +32 (0) 11 29 41 12 [email protected] jaga.com JAGA INTERNATIONAL