LINEA PLUS HYBRID
Open the catalog to page 1Optional towel rail 5 Which Jaga control system to choose 7 Connection left or right with controls below (Standard) 8 Connection left or right with controls above 8 Connection left or right with remote control 8 Most used connection sets 9 Guideline for limiting flow noise 20
Open the catalog to page 34 - Linea Plus Hybrid
Open the catalog to page 4LINEA PLUS HYBRID DIMENSIONS (in mm) Type 11 STANDARD DELIVERY - Low-H2O heat exchanger, with dirt and dust repellent coating in graphite grey (RAL 7024) - wall brackets and mounting set - angled air vent (standard and Height 020) or extended 1/8” air vent (twin) and 1/2” drain cock - partially assembled casing for a connection on the bottom left or bottom right - easy to install fan unit with operation, control and 24VDC power supply This heater is not equipped with a condensation monitor. It has to be integrated into the installation (only for cooling). COLOURS Eco-friendly, scratch-resistant...
Open the catalog to page 5CONTROL SYSTEMS LINEA PLUS HYBRIDTYPE POSITION Jaga ACO (D09) ® EXTERNAL 0-10 V CONTROL ^^se^SoER^^ - ✓ JAGA ACO (D09) - The fan speed is selected manually in 3 modes via the control panel. - When the water temperature is lower than 24°C and the air is warmer than the water in the heat exchanger, the fans will start. The unit will then cool the area. - When the water temperature is higher than 28°C and the air is colder than the water, the fans will start. The unit will then heat the area. - The unit will automatically switch from heating to cooling and to standby mode. JAGA BMS 0-10V CONTROL...
Open the catalog to page 6LINEA PLUS HYBRID WHICH JAGA CONTROL SYSTEM TO CHOOSE Would you like the unit to have room temperature control? Yes, unit with integrated room temperature control Fans will start automatically when the internal control sends warm/cold water through the radiator. No, unit without integrated room temperature control Fans will start automatically when the external control sends warm/cold water through the radiator LINEA PLUS HYBRID LINEA PLUS HYBRID Without 0-10V signal: - room thermostat (None-Jaga) - area control with room temperature control - boiler or heat pump control with room temperature...
Open the catalog to page 7LINEA PLUS HYBRID HYDRONIC CONNECTION STANDARD: CONNECTION LEFT OR RIGHT WITH CONTROLS BELOW Left or right downwards, to the wall or to the floor. Wall connection from the underside of the panelling or completely concealed within the panelling. The installer can rotate the heat exchanger to accomodate a left or right-side connection. Compatible Eurocone connection sets: 101, 102, 103, 104, 181, 182, 183, 184, 222, 225, 226, 282, 285 Compatible M24 connection sets: 11, 12, 13, 14, 25 Example of connection to the right (standard) max. 82 Example of connection to the left CONNECTION LEFT OR RIGHT...
Open the catalog to page 8MOST USED CONNECTION SETS To the wall - FLOW ON THE OUTSIDE To the floor - FLOW ON THE OUTSIDE With Jaga H-valve With Gampper Vario DP Dynamic valve With Jaga H-valve With Gampper Vario DP Dynamic valve fill in sleeve coupling code fill in sleeve coupling code fill in sleeve coupling code fill in sleeve coupling code To the wall - FLOW ON THE INSIDE To the floor - FLOW ON THE INSIDE With Jaga Crossflow valve With Gampper Vario DP Dynamic valve With Jaga Crossflow valve With Gampper Vario DP Dynamic valve automatic flow COLO GACW AC 4... COLO GACW AW 4... COLO GACW AS 4... COLO GACW AB 4... COLO...
Open the catalog to page 9LINEA PLUS HYBRID Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. 10 - Linea Plus Hybrid enter colour code enter control system code
Open the catalog to page 10Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. enter cotour code enter control system CLIMATE DESIGNERS
Open the catalog to page 11Type 11 Type 16 Type 21 Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. 12 - Linea Plus Hybrid LINW 050 050 11 XXX DDD enter colour code enter control system code
Open the catalog to page 12a UfU Uiu Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. CLIMATE DESIGNERS Watts Watts Watts Watts Watts enter colour code enter control system
Open the catalog to page 13Type 11 Type 16 Type 21 Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. 14 - Linea Plus Hybrid LINW 065 060 11 XXX DDD enter colour code enter control system code
Open the catalog to page 14Type 11 Type 16 Type 21 16/18 Watts 35/30Watts 45/40 50/45Watts Watts 55/45Watts dB(A) Watts kg L Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. CLIMATE DESIGNERS
Open the catalog to page 15Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/ reverberation time 0.5 sec. 16 - Linea Plus Hybrid Watts Watts Watts Watts Watts enter colour code enter control system code
Open the catalog to page 16CLIMATE DESIGNERS
Open the catalog to page 17STANDARD DELIVERY: - front panel - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart ORDER CODE STANDARD DELIVERY: - heat exchanger - wall brackets - angled air vent (for types 10, 15 and 20) or extended air vent (for types 11, 16 and 21) ORDER CODE STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart ORDER CODE STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart ORDER CODE STANDARD DELIVERY: - Standard colours: 133, 001 or 145 other colours: see Jaga colour chart ORDER CODE Number of brackets...