1. Catalogs
  2. JAGA
  3. Eco Reviva Hybrid

Eco Reviva Hybrid

Eco Reviva Hybrid
1 / 36 PagesView full catalog

Eco Reviva Hybrid

Product catalog summary
Overview: The document provides comprehensive technical details about the EcoReviva Hybrid radiator, covering specifications, control systems, and performance data for various models and configurations. It also includes guidelines for selecting appropriate models based on specific requirements.
Technical Specifications:
  • Dimensions: Available in various heights and lengths, with specific measurements for each model type.
  • Standard Delivery: Includes a one-piece casing, detachable front panel, Low-H2O heat exchanger, pre-assembled fan unit, and necessary hydronic connection components.
  • Colours: Eco-friendly, scratch-resistant powder coating available in standard and custom colours.
Control Systems:
  • Jaga ACO (D09): Manual fan speed control with automatic switching between heating and cooling based on water and air temperature.
  • Jaga BMS 0-10V Control (D03): Fan speed controlled by an external 0-10V signal, compatible with home automation systems.
Hydronic and Electrical Connections:
  • Multiple water-side connection options, with a standard 67 connection adjustable on-site.
  • Electrical connection options vary based on unit height, with a 24 VDC power supply included.
Performance Data:
  • Tables provide heating and cooling outputs, sound pressure levels, and power consumption for different heights and types.
  • Output measured according to EN 16430 standards, and noise levels measured according to ISO 3741:2010.
Recommendations:
  • Select the appropriate control system based on desired automation and integration with existing systems.
  • Consider specific heating and cooling requirements when choosing a model and configuration.
Specifications: The EcoReviva Hybrid units are available in different heights (045, 050, 055) and types (Type 11, Type 16, Type 21), with power output listed for both cooling (at 27°C) and heating (at 20°C) conditions.
Noise and Standards: Noise measurements conducted according to ISO 3741:2010 standards, with output measured in accordance with EN 16430 standards.
Key Parameters: Highlights critical parameters such as power consumption, sound pressure levels, and performance efficiency across different models and configurations. Includes order codes for product identification and ordering.
Heat Exchangers: Lists different types of heat exchangers (Type 11, Type 16, Type 21) with specific order codes and dimensions, providing correction factors for various temperature differences (∆T) and room temperatures.
Multilayer Pipes: Details various pipe sizes and corresponding order codes, along with specifications for T-pieces, sleeve couplings, and drain cocks.
Performance Metrics: Includes tables for average correction factors at different room temperatures and ∆T values, guidelines for limiting flow noise, and maximum power outputs at various ∆T levels.
Pressure Drop Charts: Charts for pressure drop across different types of heat exchangers (Type 11, Type 16, Type 21), showing working pressure and water flow rates.
Contact Information: For further advice, contact details for Jaga International are provided, including phone number and email.
See more

Catalog excerpts

Eco Reviva Hybrid-3

Which Jaga control system to choose 7 Guideline for limiting flow noise 32

 Open the catalog to page 3
Eco Reviva Hybrid-4

DIMENSIONS (in mm) STANDARD DELIVERY - one-piece casing (rear panel, bottom grille, exhaust grille and side panels) - detachable front panel - Low-H2O heat exchanger, with dirt and dust repellent coating in graphite grey (RAL 7024) - pre-assembled fan unit with operating panel, control system and 24 VDC power supply. - multilayer pipe, T-piece, 1/2” vent plug, 2 1/2” drain cocks and compression fittings for internal hydronic connection - hanger bolts: if necessary, adjust distance wall - rear panel (0 <35 mm) COLOURS Eco-friendly, scratch-resistant powder coating with high Standard colours -...

 Open the catalog to page 4
Eco Reviva Hybrid-5

WATER-SIDE CONNECTION OPTIONS (1/2” female thread) EcoReviva Hybrid is a renovation radiator that provides a solution for any existing connection. Thanks to the included multilayer pipe and T-piece, a concealed hydronic solution is integrated within the unit. The units are always supplied with a 67 connection, which can be adjusted on-site as needed. ELECTRICAL CONNECTION Option 1 : HEIGHT > 050 From height 50, it is possible to use the power adapter (230 VAC - 24 VDC) that comes included. Option 2: HEIGHT < 050 Fit the supplied power adapter outside the unit. Option 3: All height dimensions...

 Open the catalog to page 5
Eco Reviva Hybrid-6

CONTROL SYSTEMS ECOREVIVA HYBRID CONTROL SYSTEMS CONTROL PANEL EXTERNAL 0-10 V WATER TEMPERATURE AIR TEMPERATURE CONTROL SENSOR SENSOR - The fan speed is selected manually in 3 modes via the control panel. - When the water temperature is lower than 24°C and the air is warmer than the water in the heat exchanger, the fans will start. The unit will then cool the area. - When the water temperature is higher than 28°C and the air is colder than the water, the fans will start. The unit will then heat the area. - The unit will automatically switch from heating to cooling and to standby mode. - The...

 Open the catalog to page 6
Eco Reviva Hybrid-7

ECOREVIVA HYBRID WHICH JAGA CONTROL SYSTEM TO CHOOSE Would you like the unit to have room temperature control? Yes, unit with integrated room temperature control Fans will start automatically when the internal control sends warm/cold water through the radiator. No, unit without integrated room temperature control Fans will start automatically when the external control sends warm/ cold water through the radiator ECOREVIVA HYBRID ECOREVIVA HYBRID Without 0-10V signal: - room thermostat (None-Jaga) - area control with room temperature control - boiler or heat pump control with room temperature control...

 Open the catalog to page 7
Eco Reviva Hybrid-8

Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 8
Eco Reviva Hybrid-9

HEIGHT 040 Type 11 Type 16 Type 21 Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code CLIMATE DESIGNERS

 Open the catalog to page 9
Eco Reviva Hybrid-10

HEIGHT 045 Type 11 Type 16 Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 10
Eco Reviva Hybrid-11

HEIGHT 045 Type 11 Type 16 Type 21 Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code CLIMATE DESIGNERS

 Open the catalog to page 11
Eco Reviva Hybrid-12

HEIGHT 050 Type 11 Type 16 Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 12
Eco Reviva Hybrid-13

HEIGHT 050 Type 11 Type 16 Watts Watts Watts Watts Watts CLIMATE DESIGNERS Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 13
Eco Reviva Hybrid-14

Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 14
Eco Reviva Hybrid-15

Watts Watts Watts Watts Watts CLIMATE DESIGNERS Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 15
Eco Reviva Hybrid-16

Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 16
Eco Reviva Hybrid-17

Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code CLIMATE DESIGNERS

 Open the catalog to page 17
Eco Reviva Hybrid-18

HEIGHT 065 Type 11 Type 16 Type 21 Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code

 Open the catalog to page 18

All JAGA catalogs and technical brochures

  1. Clima Beam

    52  Pages

  2. Mini Hybrid

    10  Pages

  3. Strada Hybrid

    26  Pages

  4. Vertiga Hybrid

    20  Pages

  5. Stada Hybrid MM

    20  Pages

  6. Clima Canal 19

    32  Pages

  7. Clima Canal 10

    24  Pages

  8. Clima Canal 08

    24  Pages

  9. BRIZA

    208  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.