ECOREVIVA HYBRID
Open the catalog to page 1Which Jaga control system to choose 7 Guideline for limiting flow noise 32
Open the catalog to page 3DIMENSIONS (in mm) STANDARD DELIVERY - one-piece casing (rear panel, bottom grille, exhaust grille and side panels) - detachable front panel - Low-H2O heat exchanger, with dirt and dust repellent coating in graphite grey (RAL 7024) - pre-assembled fan unit with operating panel, control system and 24 VDC power supply. - multilayer pipe, T-piece, 1/2” vent plug, 2 1/2” drain cocks and compression fittings for internal hydronic connection - hanger bolts: if necessary, adjust distance wall - rear panel (0 <35 mm) COLOURS Eco-friendly, scratch-resistant powder coating with high Standard colours -...
Open the catalog to page 4WATER-SIDE CONNECTION OPTIONS (1/2” female thread) EcoReviva Hybrid is a renovation radiator that provides a solution for any existing connection. Thanks to the included multilayer pipe and T-piece, a concealed hydronic solution is integrated within the unit. The units are always supplied with a 67 connection, which can be adjusted on-site as needed. ELECTRICAL CONNECTION Option 1 : HEIGHT > 050 From height 50, it is possible to use the power adapter (230 VAC - 24 VDC) that comes included. Option 2: HEIGHT < 050 Fit the supplied power adapter outside the unit. Option 3: All height dimensions...
Open the catalog to page 5CONTROL SYSTEMS ECOREVIVA HYBRID CONTROL SYSTEMS CONTROL PANEL EXTERNAL 0-10 V WATER TEMPERATURE AIR TEMPERATURE CONTROL SENSOR SENSOR - The fan speed is selected manually in 3 modes via the control panel. - When the water temperature is lower than 24°C and the air is warmer than the water in the heat exchanger, the fans will start. The unit will then cool the area. - When the water temperature is higher than 28°C and the air is colder than the water, the fans will start. The unit will then heat the area. - The unit will automatically switch from heating to cooling and to standby mode. - The...
Open the catalog to page 6ECOREVIVA HYBRID WHICH JAGA CONTROL SYSTEM TO CHOOSE Would you like the unit to have room temperature control? Yes, unit with integrated room temperature control Fans will start automatically when the internal control sends warm/cold water through the radiator. No, unit without integrated room temperature control Fans will start automatically when the external control sends warm/ cold water through the radiator ECOREVIVA HYBRID ECOREVIVA HYBRID Without 0-10V signal: - room thermostat (None-Jaga) - area control with room temperature control - boiler or heat pump control with room temperature control...
Open the catalog to page 7Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 8HEIGHT 040 Type 11 Type 16 Type 21 Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code CLIMATE DESIGNERS
Open the catalog to page 9HEIGHT 045 Type 11 Type 16 Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 10HEIGHT 045 Type 11 Type 16 Type 21 Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code CLIMATE DESIGNERS
Open the catalog to page 11HEIGHT 050 Type 11 Type 16 Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 12HEIGHT 050 Type 11 Type 16 Watts Watts Watts Watts Watts CLIMATE DESIGNERS Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 13Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 14Watts Watts Watts Watts Watts CLIMATE DESIGNERS Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 15Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 16Watts Watts Watts Watts Watts Output measured in accordance with EN 16430 *Woise measurement according to /SO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dBA/room volume 100 m3 / reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code CLIMATE DESIGNERS
Open the catalog to page 17HEIGHT 065 Type 11 Type 16 Type 21 Watts Watts Watts Watts Watts Output measured in accordance with EN16430 *Noise measurement according to ISO 3741:2010, at a 2-m distance from the unit and with an assumed room attenuation of 8 dB(A)/room volume 100 m3/reverberation time 0.5 sec. Enter colour code Enter control system code Enter model code
Open the catalog to page 1852 Pages
10 Pages
26 Pages
24 Pages
20 Pages
20 Pages
31 Pages
32 Pages
32 Pages
24 Pages
24 Pages
208 Pages