Manual_JOTUL_F 230 - 1

UK - Installation and Operating Instructions The manuals which are enclosed with the product must be kept throughout the product’s entire service life. Register your fireplace at jotul.com for a 25-year war

Open the catalog to page 1
Manual_JOTUL_F 230 - 4

Installation of a fireplace must be according to local codes and regulations in each country. All local regulations, including those which refer to national and European standards, must be observed when installing the product. The installation can only be put into use after it has been checked by a qualified inspector. Contact your local building authorities before installing a new fireplace. Register your fireplace at jotul.com for a 25-year warranty. 2.0 Technical data Material: Finish: Fuel: Log length, max.: Flue outlet: Flue pipe dimension: Cast iron / steel plate Black paint Wood 33...

Open the catalog to page 4
Manual_JOTUL_F 230 - 5

3.0 Safety NB! To guarantee optimal performance and safety, Jotui recommends that its stoves are fitted by a qualified installer (see www.jotul.com for a complete list of dealers). Any modifications to the product may result in the product and safety features not functioning as intended. The same applies to the installation of accessories or optional extras not supplied by J0tul. This may also be the case if parts that are essential to the functioning and safety of the fireplace have been disassembled or removed. In all these cases, the manufacturer is not responsible or liable for the...

Open the catalog to page 5
Manual_JOTUL_F 230 - 6

Radiation zone 21-08-2017 NAVN: X/Y Jøtul F 230 acc. to national standards Målskitse ( model 235 ) MATERIALE: EMNE: M3 NR.: distance to furniture / combustible material STI: Scan A/S DK-5492 Vissenbjerg© EMNE: Jøtul F 230 Bagudgang / gulvplade

Open the catalog to page 6
Manual_JOTUL_F 230 - 7

Målskitse ( model 234 ) VÆGT: N/A TG.NR: DATO: Scan A/S DK-5492 Vissenbjerg© NAVN: Målskitse ( model 234 ) VÆGT: N/A MATERIALE: AREAL: C:\Working Folder\Designs\Jøtul F230\90230136.idw Målskitse ( model EMNE: TG.NR: DATO: Scan A/S DK-5492 Vissenbjerg© TG.NR: DATO:

Open the catalog to page 7
Manual_JOTUL_F 230 - 8

3. Remove the three transportation safety screws (F) in the sides and at the front in order to free the stove from the pallet. The air used for combustion in any well-insulated house needs to be replaced. This is particularly important in houses with mechanical ventilation. This can be done by using a balanced flue pipe. The most important thing is to supply the air to the room where the stove is placed. Important! Ensure that air vents in the room where the fireplace is located are not blocked. For the fresh air supply connection, follow the national and local building regulations. •...

Open the catalog to page 8
Manual_JOTUL_F 230 - 9

Min. distance to firewall with insulated flue pipe Brandmur F.eks. 50 mm. Jøtul firewall NAVN: Brandbart materiale Brandmur F.eks. 50 mm. Jøtul firewall 10-08-2017 SIGN: jm NAVN: Jøtul F 230 Brandbart materiale Opstilling til brandmur hjørne Min. distance to combustible wall with insulated flue pipe M3 NR.: TG.NR: DATO: Afstand til brændbar væg VÆGT: N/A Afstand til brændbar væg VÆGT: N/A 90230153 C:\Working Folder\Designs\Jøtul F230\90230154.idw SIGN: jm TG.NR: DATO: Min. distance to combustible wall without insulated flue pipe 125 Afstand til brændbar væg VÆGT: N/A TG.NR: DATO: Alle mål...

Open the catalog to page 9
Manual_JOTUL_F 230 - 10

4.2 Chimney and flue pipe • The fireplace must only be connected to a chimney and flue pipe approved for solid fuel fireplaces with flue gas temperatures as specified in «2.0 Technical Data» G • The distance of the flue pipe to combustible materials must also be observed • The cross-section of the chimney must be designed to fit the fireplace. Use «2.0 Technical Data» calculate the correct chimney cross-section • The chimney must be connected in accordance with the installation instructions of the chimney supplier • Before a hole is made in the chimney, the product should be test-mounted in...

Open the catalog to page 10
Manual_JOTUL_F 230 - 11

Mounting of the balanced flue pipe (delivered as standard) The stove is prepared for a balanced vent from the factory. The chimney consists of a double pipe. The outer pipe is used by the stove to draw in fresh air for the combustion. The inner pipe is used by the stove to exhaust the burnt gases. This is called a balanced vent. 1. The adapter (A) delivered with the stove fits the Jøtul NVI 2000 Combi. 2. You should alwasys start with a half-insulated chimney length (B). The first module is mounted directly on the adapter. (Read more under ”9.0 Optional Equipment”). NB! It is important for...

Open the catalog to page 11
Manual_JOTUL_F 230 - 12

Assembly of flue pipe with ordinary (non-balanced) outlet Uninsulated flue pipe with top outlet 1. Position the product correctly (see fig. 1). B C 2. Place the cover (accessory) (D) in the top outlet and fasten it. C 2. Position the décor ring (accessory) (C) in the top outlet. 3. Pass the flue pipe (A) through the décor ring (C) and the top plate and mount it in the connecting piece. NB: It is important for the joints/flue pipes to be sealed completely. Air leaks may prevent them from operating properly. Flue pipe with rear outlet The product is assembled with the smoke outlet (A) fitted...

Open the catalog to page 12
Manual_JOTUL_F 230 - 13

4.3 Floor plate (Optional equipment) If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any non-flammable subsurface required to cover the floor around the stove. Once the product has been assembled, always check the control handles. These should move and work in a satisfactory manner. B Your local Jøtul dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove. The floor plate’s function is to protect the floor and flammable material against any sparks that may...

Open the catalog to page 13
Manual_JOTUL_F 230 - 14

J0tul F 230 is equipped with the following operating options: Lever for igniting the stove (A): Vertical position (F): Closed Horizontal position (G): Open Ignition lever (Air through the bottom) (B) Pushed back: Open Pulled forward: Closed Secondary combustion lever (Glass air wash) (C) Pushed back: Open Pulled forward: Closed Door handle (D): Open by pulling the handle. Stacking height for logs (E) (The holes must not be covered). 5.0 Daily use Odours when using the fireplace for the first time When the fireplace is used for the first time, it may emit an irritating gas...

Open the catalog to page 14